Skip to main content
VulnerabilityPublished Updated

CVE-2025-30240: TP-Link Systems HB810(US2) V1.0/1.6/2.0/2.6 · Improper Link Resolution Before File Access

Affects TP-Link Systems HB810(US2) V1.0/1.6/2.0/2.6Source CVE Database V5

0
Compare

Not known to be exploited · CVSS 5.1 Medium : upgrade to 0.9.0 3.2.2 v6095.0 Build 260717 Rel.67188n when convenient.

Data as of 8 Nov 2026, 23:23 UTC

CVSS 4.0 base score
5.1Medium
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.2% chance of exploitation in 30 days – higher than 14% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
Patch
Available – fixed in 0.9.0 3.2.2 v6095.0 Build 260717 Rel.67188n, 0.10.0 3.2.2 v6095.0 Build 260306 Rel.47567n, 0.3.0 3.0.0 v60be.0 Build 251128 Rel.43956n +20
CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 10 Aug 2026

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponized: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 8 Nov 2026.

What to do

Upgrade to a fixed release listed under Affected software.

Affected software

ProductAffectedFixed in
TP-Link Systems Inc.HB810(US2) V1.0/1.6/2.0/2.6Affected
  • =0
Fixed in
  • 0.9.0 3.2.2 v6095.0 Build 260717 Rel.67188n
TP-Link Systems Inc.HB810(EU1) V2.0Affected
  • =0
Fixed in
  • 0.10.0 3.2.2 v6095.0 Build 260306 Rel.47567n
TP-Link Systems Inc.HB710(US2) V1.6/1.0Affected
  • =0
Fixed in
  • 0.3.0 3.0.0 v60be.0 Build 251128 Rel.43956n
TP-Link Systems Inc.HB710(EU1) 1.0Affected
  • =0
Fixed in
  • 0.3.0 3.0.0 v60be.0 Build 251128 Rel.43956n
TP-Link Systems Inc.HB610(US2) V2.6/2.0Affected
  • =0
Fixed in
  • 0.6.0 3.0.0 v60af.0 Build 251204 Rel.20362n
TP-Link Systems Inc.HB610(EU1)Affected
  • =0
Fixed in
  • 0.6.0 3.0.0 v60af.0 Build 251204 Rel.20362n

AI-suggested

If you cannot patch yet, restrict physical access to the device and external USB ports to trusted users only.

Description

The affected TP-Link Aginet devices do not properly validate symbolic links created on external USB storage devices. By placing a crafted symbolic link on supported storage media, an attacker may cause the system to resolve the link. Successful exploitation may allow unauthorized read access to sensitive files within the device filesystem.

References

Community reviews

Loading reviews…