Skip to main content
CVE-2025-39204VulnerabilityPublished Updated

CVE-2025-39204: Hitachi Energy MicroSCADA X SYS600 · Information Exposure

Affects Hitachi Energy MicroSCADA X SYS600Source CVE Database V5

0

Not known to be exploited · CVSS 8.5 High.

Data as of 25 Oct 2026, 19:02 UTC

CVSS 4.0 base score
8.5High
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.3% chance of exploitation in 30 days – higher than 29% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 24 Jun 2025

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 2026-10-25.

What to do

Affected software

ProductAffectedFixed in
Hitachi Energy MicroSCADA X SYS600Affected
  • =10.0
Fixed in–

AI-suggested

1. Immediate network segmentation: Isolate MicroSCADA X SYS600 web interfaces from general corporate networks and restrict access to trusted administrative hosts only, using strict firewall rules and network access controls. 2. Implement strict access control policies: Enforce the principle of least privilege for all users with access to the MicroSCADA system, ensuring that only necessary personnel have even low-level privileges. 3. Monitor and log all access to the MicroSCADA web interface, with particular attention to unusual query patterns that may indicate attempts to exploit malformed filtering queries. 4. Deploy Web Application Firewalls (WAFs) with custom rules to detect and block malformed query patterns targeting the filtering mechanism. 5. Engage with Hitachi Energy for timely updates and patches; prioritize patching as soon as a fix is released. 6. Conduct regular security assessments and penetration testing focused on the MicroSCADA environment to identify potential exploitation attempts or other vulnerabilities. 7. Educate operational technology (OT) security teams about this vulnerability and ensure incident response plans include scenarios involving data leakage from ICS web interfaces. 8. Consider implementing additional encryption and data masking techniques within the SCADA environment to reduce the impact of any potential data exposure.

Description

A vulnerability exists in the Web interface of the MicroSCADA X SYS600 product. The filtering query in the Web interface can be malformed, so returning data can leak unauthorized information to the user.

References

Community reviews

Loading reviews…