Skip to main content

CVE-2025-40577: CWE-125: Out-of-bounds Read in Siemens SCALANCE LPE9403

Medium
VulnerabilityCVE-2025-40577cvecve-2025-40577cwe-125
Published: Tue May 13 2025 (05/13/2025, 09:39:02 UTC)
Source: CVE
Vendor/Project: Siemens
Product: SCALANCE LPE9403

Description

A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices do not properly validate incoming Profinet packets. An unauthenticated remote attacker can exploit this flaw by sending a specially crafted malicious packet, which leads to a crash of the dcpd process.

AI-Powered Analysis

AILast updated: 07/12/2025, 02:04:14 UTC

Technical Analysis

CVE-2025-40577 is a medium-severity vulnerability identified in Siemens SCALANCE LPE9403 industrial network devices, specifically versions prior to V4.0 HF0. The vulnerability is classified as CWE-125, an out-of-bounds read flaw. It arises because the affected SCALANCE LPE9403 devices do not properly validate incoming Profinet packets. Profinet is a widely used industrial Ethernet standard for automation, and improper validation allows an unauthenticated remote attacker to send specially crafted malicious packets to the device. Exploiting this flaw causes the dcpd process, a critical component of the device's communication stack, to crash, resulting in a denial-of-service (DoS) condition. The vulnerability does not impact confidentiality or integrity but affects availability by crashing the process. The CVSS v3.1 base score is 4.3, reflecting a medium severity with attack vector as adjacent network, low attack complexity, no privileges required, and no user interaction needed. No known exploits are reported in the wild as of the published date. Siemens has not yet published a patch or mitigation guidance, and the vulnerability affects all versions prior to V4.0 HF0. This vulnerability is significant in industrial control environments where SCALANCE LPE9403 devices are deployed to manage network communication for automation systems. An attacker exploiting this flaw could disrupt industrial processes by causing network device failures, potentially impacting operational continuity.

Potential Impact

For European organizations, particularly those in manufacturing, energy, transportation, and critical infrastructure sectors relying on Siemens SCALANCE LPE9403 devices, this vulnerability poses a risk of operational disruption. The denial-of-service condition caused by crashing the dcpd process can interrupt network communications within industrial control systems, leading to downtime or degraded performance of automated processes. This could result in production delays, safety risks, or financial losses. Since the vulnerability requires no authentication and no user interaction, it can be exploited by an attacker with access to the industrial network or adjacent network segments, increasing the risk in environments with insufficient network segmentation. Although the vulnerability does not allow data theft or manipulation, the availability impact on critical industrial networks can have cascading effects on supply chains and service delivery. European organizations with extensive Siemens industrial automation deployments should prioritize assessing exposure and mitigating risks to maintain operational resilience.

Mitigation Recommendations

1. Immediate network segmentation: Isolate SCALANCE LPE9403 devices from general IT networks and restrict access to trusted industrial network segments only. 2. Implement strict firewall rules and access control lists (ACLs) to block unauthorized Profinet traffic from untrusted sources, limiting exposure to adjacent network attackers. 3. Monitor network traffic for anomalous or malformed Profinet packets that could indicate exploitation attempts. 4. Coordinate with Siemens for timely updates and apply firmware version V4.0 HF0 or later as soon as it becomes available to remediate the vulnerability. 5. Conduct regular vulnerability assessments and penetration testing focused on industrial network devices to identify and mitigate similar issues proactively. 6. Develop and test incident response plans specific to industrial network device failures to minimize downtime impact. 7. Consider deploying intrusion detection/prevention systems (IDS/IPS) with signatures or heuristics for Profinet protocol anomalies once available.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
siemens
Date Reserved
2025-04-16T08:20:17.032Z
Cisa Enriched
true
Cvss Version
3.1
State
PUBLISHED

Threat ID: 682d9816c4522896dcbd65bb

Added to database: 5/21/2025, 9:08:38 AM

Last enriched: 7/12/2025, 2:04:14 AM

Last updated: 8/5/2025, 4:45:02 PM

Views: 11

Actions

PRO

Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.