CVE-2025-40771: CWE-306: Missing Authentication for Critical Function in Siemens SIMATIC CP 1542SP-1

0
Critical
VulnerabilityCVE-2025-40771cvecve-2025-40771cwe-306
Published: Tue Oct 14 2025 (10/14/2025, 09:15:17 UTC)
Source: CVE Database V5
Vendor/Project: Siemens
Product: SIMATIC CP 1542SP-1

Description

A vulnerability has been identified in SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.4.24). Affected devices do not properly authenticate configuration connections. This could allow an unauthenticated remote attacker to access the configuration data.

AI-Powered Analysis

AILast updated: 10/21/2025, 11:52:13 UTC

Technical Analysis

CVE-2025-40771 is a vulnerability categorized under CWE-306 (Missing Authentication for Critical Function) affecting Siemens SIMATIC CP 1542SP-1 and related communication processors used in industrial automation. The affected devices, including SIMATIC CP 1542SP-1, CP 1543SP-1, and SIPLUS ET 200SP variants, do not properly authenticate configuration connections in all versions prior to V2.4.24. This lack of authentication means that an unauthenticated remote attacker can connect to these devices and access or modify configuration data without any credentials. The vulnerability is remotely exploitable over the network without requiring user interaction or privileges, as indicated by the CVSS vector AV:N/AC:L/PR:N/UI:N. The impact on confidentiality, integrity, and availability is high, as attackers can potentially alter device configurations, disrupt industrial communication, and cause operational failures. Siemens has reserved the CVE and published the vulnerability in October 2025, but no known exploits in the wild have been reported yet. The devices affected are widely used in industrial control systems (ICS) and critical infrastructure environments, making this vulnerability particularly dangerous in such contexts.

Potential Impact

For European organizations, especially those operating in industrial automation, manufacturing, energy, and critical infrastructure sectors, this vulnerability poses a severe risk. Unauthorized access to configuration data can lead to manipulation of industrial communication parameters, potentially causing process disruptions, safety incidents, or production downtime. The high CVSS score reflects the ease of exploitation and the critical nature of the impact on confidentiality, integrity, and availability. Given the widespread use of Siemens SIMATIC CP devices across Europe, exploitation could have cascading effects on supply chains and critical services. Additionally, the lack of authentication could allow attackers to establish persistent footholds or pivot within industrial networks, increasing the risk of broader attacks. The absence of known exploits in the wild currently provides a window for proactive mitigation, but the critical severity demands urgent attention.

Mitigation Recommendations

1. Immediately upgrade all affected Siemens SIMATIC CP 1542SP-1 and related devices to firmware version 2.4.24 or later once Siemens releases the patch. 2. Until patches are applied, implement strict network segmentation to isolate these devices from untrusted networks and limit access to trusted management stations only. 3. Employ firewall rules and access control lists (ACLs) to restrict configuration port access to authorized IP addresses. 4. Monitor network traffic for unusual connection attempts to the configuration interfaces of these devices. 5. Use industrial intrusion detection systems (IDS) tailored to detect unauthorized configuration access attempts. 6. Conduct regular audits of device configurations and logs to detect unauthorized changes. 7. Engage with Siemens support for any interim mitigation guidance or firmware updates. 8. Incorporate this vulnerability into incident response plans specific to industrial control systems to ensure rapid containment if exploited.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
siemens
Date Reserved
2025-04-16T08:39:30.033Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 68ee16317eab8b438c025d5c

Added to database: 10/14/2025, 9:21:53 AM

Last enriched: 10/21/2025, 11:52:13 AM

Last updated: 11/30/2025, 9:39:33 AM

Views: 173

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.

Latest Threats