CVE-2025-40937: CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection') in Siemens SIMATIC CN 4100

0
High
VulnerabilityCVE-2025-40937cvecve-2025-40937cwe-77
Published: Tue Dec 09 2025 (12/09/2025, 10:44:35 UTC)
Source: CVE Database V5
Vendor/Project: Siemens
Product: SIMATIC CN 4100

Description

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0.1). The affected application do not properly validate input parameters in its REST API, resulting in improper handling of unexpected arguments. This could allow an authenticated attacker to execute arbitrary code with limited privileges.

AI-Powered Analysis

AILast updated: 12/09/2025, 11:13:16 UTC

Technical Analysis

CVE-2025-40937 is a command injection vulnerability classified under CWE-77 that affects Siemens SIMATIC CN 4100 devices running versions earlier than 4.0.1. The root cause is improper neutralization of special elements in input parameters processed by the device's REST API. Specifically, the application fails to adequately validate or sanitize input arguments, allowing an authenticated attacker to inject malicious commands. Exploitation requires authentication but no user interaction, and can be performed remotely over the network. Successful exploitation enables the attacker to execute arbitrary code with limited privileges on the affected device, potentially leading to unauthorized access, data manipulation, or further lateral movement within industrial control networks. The vulnerability has a CVSS v3.1 base score of 8.3, indicating high severity, with metrics AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L, meaning it is remotely exploitable with low attack complexity, requires low privileges, no user interaction, and impacts confidentiality and integrity significantly, with limited availability impact. No public exploits are currently known, but the vulnerability is published and should be addressed promptly. Siemens SIMATIC CN 4100 is widely used in industrial automation environments, making this vulnerability particularly critical for operational technology (OT) security.

Potential Impact

For European organizations, especially those in manufacturing, energy, and critical infrastructure sectors relying on Siemens SIMATIC CN 4100, this vulnerability poses a significant risk. Exploitation could lead to unauthorized command execution, resulting in data breaches, manipulation of industrial processes, or disruption of operations. The confidentiality and integrity of sensitive operational data could be compromised, potentially affecting product quality, safety, and compliance with regulatory requirements such as NIS2. Although availability impact is rated low, any unauthorized code execution in OT environments can have cascading effects on system stability and safety. The vulnerability's remote exploitability increases the attack surface, particularly if devices are exposed to less secure networks or insufficiently segmented environments. European organizations with interconnected IT and OT networks may face increased risk of lateral movement by attackers leveraging this flaw. The lack of known exploits currently provides a window for proactive mitigation before widespread exploitation occurs.

Mitigation Recommendations

1. Immediately upgrade all Siemens SIMATIC CN 4100 devices to version 4.0.1 or later, where the vulnerability is fixed. 2. Implement strict input validation and sanitization on all REST API endpoints to prevent injection of malicious commands. 3. Enforce strong authentication and access control policies to limit access to the REST API only to trusted and authorized users. 4. Segment industrial control networks from corporate IT networks and restrict network access to SIMATIC CN 4100 devices using firewalls and network access control lists. 5. Monitor network traffic and device logs for unusual command execution patterns or unauthorized access attempts. 6. Conduct regular vulnerability assessments and penetration testing focused on OT environments to detect similar weaknesses. 7. Develop and test incident response plans specific to OT environments to quickly contain and remediate any exploitation attempts. 8. Collaborate with Siemens support and subscribe to their security advisories for timely updates and patches.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.2
Assigner Short Name
siemens
Date Reserved
2025-04-16T09:06:15.878Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 6938009229016b16de45feed

Added to database: 12/9/2025, 10:57:22 AM

Last enriched: 12/9/2025, 11:13:16 AM

Last updated: 12/10/2025, 11:25:48 PM

Views: 19

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.

Latest Threats