Skip to main content
CVE-2025-40937VulnerabilityPublished

CVE-2025-40937: Siemens SIMATIC CN 4100 · Command Injection

Affects Siemens SIMATIC CN 4100Source CVE Database V5

0

Not known to be exploited · CVSS 8.3 High.

Data as of 26 Oct 2026, 06:26 UTC

CVSS 3.1 base score
8.3High
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.5% chance of exploitation in 30 days – higher than 47% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 9 Dec 2025

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 2026-10-26.

What to do

Affected software

ProductAffectedFixed in
Siemens SIMATIC CN 4100Affected
  • =0
Fixed in–

AI-suggested

1. Apply Siemens' official patch for SIMATIC CN 4100 as soon as it becomes available to address the input validation flaw. 2. Until patches are released, restrict access to the REST API to trusted networks and authenticated users only, employing network segmentation and firewall rules. 3. Implement strict input validation and sanitization controls on all interfaces interacting with SIMATIC CN 4100 devices, if possible via proxy or gateway solutions. 4. Monitor device logs and network traffic for unusual commands or access patterns indicative of exploitation attempts. 5. Enforce the principle of least privilege for all accounts accessing the device to limit potential damage from compromised credentials. 6. Conduct regular security audits and vulnerability assessments on industrial control systems to identify and remediate similar issues proactively. 7. Train operational technology (OT) personnel on recognizing and responding to signs of command injection attacks and unauthorized access.

Description

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0.1). The affected application do not properly validate input parameters in its REST API, resulting in improper handling of unexpected arguments. This could allow an authenticated attacker to execute arbitrary code with limited privileges.