Skip to main content
CVE-2025-41004VulnerabilityPublished

CVE-2025-41004: Imaster Patient Record Management System · SQL Injection

Affects Imaster Patient Record Management SystemSource CVE Database V5

0

Not known to be exploited · CVSS 8.7 High.

Data as of 26 Oct 2026, 06:26 UTC

CVSS 4.0 base score
8.7High
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.2% chance of exploitation in 30 days – higher than 22% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 12 Jan 2026

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 2026-10-26.

What to do

Affected software

ProductAffectedFixed in
ImasterPatient Record Management SystemAffected
  • =All versions
Fixed in–

AI-suggested

To mitigate CVE-2025-41004, organizations should immediately implement strict input validation and sanitization on the ‘id’ parameter and all user inputs in the affected endpoint. Employ parameterized queries or prepared statements to prevent SQL injection attacks. Conduct a comprehensive code review of the Patient Record Management System to identify and remediate similar vulnerabilities. Restrict database user permissions to the minimum necessary to limit the impact of potential exploitation. Implement web application firewalls (WAF) with SQL injection detection and prevention rules tailored to the Imaster system’s traffic patterns. Monitor logs for unusual database queries or access patterns indicative of exploitation attempts. Since no official patches are available, consider isolating the vulnerable system segment and applying compensating controls such as network segmentation and enhanced authentication mechanisms. Engage with Imaster for timely updates and patches. Finally, ensure incident response plans are updated to address potential exploitation scenarios involving patient data breaches.

Description

Imaster's Patient Records Management System is vulnerable to SQL Injection in the endpoint ‘/projects/hospital/admin/complaints.php’ through the ‘id’ parameter.

References

Community reviews