CVE-2025-53515: CWE-89 in Advantech iView
A vulnerability exists in Advantech iView that allows for SQL injection and remote code execution through NetworkServlet.archiveTrap(). This issue requires an authenticated attacker with at least user-level privileges. Certain input parameters are not sanitized, allowing an attacker to perform SQL injection and potentially execute code in the context of the 'nt authority\local service' account.
AI Analysis
Technical Summary
CVE-2025-53515 is a high-severity vulnerability identified in Advantech iView, a product commonly used in industrial control systems and IoT device management. The vulnerability is classified under CWE-89, indicating it is an SQL injection flaw. The issue arises in the NetworkServlet.archiveTrap() function, where certain input parameters are not properly sanitized. This lack of input validation allows an authenticated attacker with at least user-level privileges to inject malicious SQL commands. Exploiting this vulnerability can lead to unauthorized database queries and potentially remote code execution (RCE) within the context of the 'NT AUTHORITY\LOCAL SERVICE' account. This account typically has limited but significant privileges on Windows systems, enabling attackers to execute arbitrary code, escalate privileges, or disrupt system operations. The vulnerability does not require user interaction but does require authentication, which means attackers must have some level of access to the system. The CVSS v3.1 score of 8.8 reflects the high impact on confidentiality, integrity, and availability, combined with low attack complexity and no user interaction needed. No known exploits are currently reported in the wild, and no patches have been linked yet, indicating that organizations should prioritize mitigation and monitoring to prevent exploitation.
Potential Impact
For European organizations, the impact of CVE-2025-53515 can be significant, especially those operating critical infrastructure, manufacturing, or industrial environments where Advantech iView is deployed. Successful exploitation could lead to unauthorized access to sensitive operational data, manipulation of industrial processes, and potential disruption of services. The ability to execute code remotely under a local service account increases the risk of lateral movement within networks, data exfiltration, and sabotage. Given the integration of Advantech iView in industrial IoT and control systems, attacks could also compromise safety mechanisms, leading to physical damage or safety hazards. The high confidentiality, integrity, and availability impact means that organizations could face operational downtime, regulatory penalties under GDPR for data breaches, and reputational damage. The requirement for authenticated access limits exposure but also highlights the importance of internal security controls and monitoring to detect insider threats or compromised credentials.
Mitigation Recommendations
To mitigate CVE-2025-53515 effectively, European organizations should: 1) Immediately audit and restrict user privileges on Advantech iView systems to the minimum necessary, ensuring that only trusted users have access. 2) Implement strong authentication mechanisms, including multi-factor authentication (MFA), to reduce the risk of credential compromise. 3) Monitor logs and network traffic for unusual SQL queries or unexpected activity related to NetworkServlet.archiveTrap() and other iView components. 4) Employ network segmentation to isolate industrial control systems and limit lateral movement if a breach occurs. 5) Apply virtual patching via web application firewalls (WAFs) or intrusion prevention systems (IPS) configured to detect and block SQL injection patterns targeting iView. 6) Engage with Advantech for timely patches or updates and plan for rapid deployment once available. 7) Conduct regular security assessments and penetration testing focused on industrial control systems to identify and remediate similar vulnerabilities proactively.
Affected Countries
Germany, France, Italy, United Kingdom, Netherlands, Belgium, Poland, Spain, Sweden, Czech Republic
CVE-2025-53515: CWE-89 in Advantech iView
Description
A vulnerability exists in Advantech iView that allows for SQL injection and remote code execution through NetworkServlet.archiveTrap(). This issue requires an authenticated attacker with at least user-level privileges. Certain input parameters are not sanitized, allowing an attacker to perform SQL injection and potentially execute code in the context of the 'nt authority\local service' account.
AI-Powered Analysis
Technical Analysis
CVE-2025-53515 is a high-severity vulnerability identified in Advantech iView, a product commonly used in industrial control systems and IoT device management. The vulnerability is classified under CWE-89, indicating it is an SQL injection flaw. The issue arises in the NetworkServlet.archiveTrap() function, where certain input parameters are not properly sanitized. This lack of input validation allows an authenticated attacker with at least user-level privileges to inject malicious SQL commands. Exploiting this vulnerability can lead to unauthorized database queries and potentially remote code execution (RCE) within the context of the 'NT AUTHORITY\LOCAL SERVICE' account. This account typically has limited but significant privileges on Windows systems, enabling attackers to execute arbitrary code, escalate privileges, or disrupt system operations. The vulnerability does not require user interaction but does require authentication, which means attackers must have some level of access to the system. The CVSS v3.1 score of 8.8 reflects the high impact on confidentiality, integrity, and availability, combined with low attack complexity and no user interaction needed. No known exploits are currently reported in the wild, and no patches have been linked yet, indicating that organizations should prioritize mitigation and monitoring to prevent exploitation.
Potential Impact
For European organizations, the impact of CVE-2025-53515 can be significant, especially those operating critical infrastructure, manufacturing, or industrial environments where Advantech iView is deployed. Successful exploitation could lead to unauthorized access to sensitive operational data, manipulation of industrial processes, and potential disruption of services. The ability to execute code remotely under a local service account increases the risk of lateral movement within networks, data exfiltration, and sabotage. Given the integration of Advantech iView in industrial IoT and control systems, attacks could also compromise safety mechanisms, leading to physical damage or safety hazards. The high confidentiality, integrity, and availability impact means that organizations could face operational downtime, regulatory penalties under GDPR for data breaches, and reputational damage. The requirement for authenticated access limits exposure but also highlights the importance of internal security controls and monitoring to detect insider threats or compromised credentials.
Mitigation Recommendations
To mitigate CVE-2025-53515 effectively, European organizations should: 1) Immediately audit and restrict user privileges on Advantech iView systems to the minimum necessary, ensuring that only trusted users have access. 2) Implement strong authentication mechanisms, including multi-factor authentication (MFA), to reduce the risk of credential compromise. 3) Monitor logs and network traffic for unusual SQL queries or unexpected activity related to NetworkServlet.archiveTrap() and other iView components. 4) Employ network segmentation to isolate industrial control systems and limit lateral movement if a breach occurs. 5) Apply virtual patching via web application firewalls (WAFs) or intrusion prevention systems (IPS) configured to detect and block SQL injection patterns targeting iView. 6) Engage with Advantech for timely patches or updates and plan for rapid deployment once available. 7) Conduct regular security assessments and penetration testing focused on industrial control systems to identify and remediate similar vulnerabilities proactively.
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- icscert
- Date Reserved
- 2025-07-02T15:12:58.638Z
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 68704d3ca83201eaacaaa063
Added to database: 7/10/2025, 11:31:08 PM
Last enriched: 7/10/2025, 11:46:20 PM
Last updated: 8/9/2025, 4:18:35 AM
Views: 12
Related Threats
CVE-2025-8604: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in wptb WP Table Builder – WordPress Table Plugin
MediumCVE-2025-9016: Uncontrolled Search Path in Mechrevo Control Center GX V2
HighCVE-2025-8451: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in wpdevteam Essential Addons for Elementor – Popular Elementor Templates & Widgets
MediumCVE-2025-8013: CWE-918 Server-Side Request Forgery (SSRF) in quttera Quttera Web Malware Scanner
LowCVE-2025-6679: CWE-434 Unrestricted Upload of File with Dangerous Type in bitpressadmin Bit Form – Custom Contact Form, Multi Step, Conversational, Payment & Quiz Form builder