Skip to main content
Press slash or control plus K to focus the search. Use the arrow keys to navigate results and press enter to open a threat.
Reconnecting to live updates…

CVE-2025-54526: CWE-121 in Fuji Electric Monitouch V-SFT-6

0
High
VulnerabilityCVE-2025-54526cvecve-2025-54526cwe-121
Published: Tue Nov 04 2025 (11/04/2025, 21:37:56 UTC)
Source: CVE Database V5
Vendor/Project: Fuji Electric
Product: Monitouch V-SFT-6

Description

Fuji Electric Monitouch V-SFT-6 is vulnerable to a stack-based buffer overflow while processing a specially crafted project file, which may allow an attacker to execute arbitrary code.

AI-Powered Analysis

AILast updated: 11/04/2025, 22:09:24 UTC

Technical Analysis

CVE-2025-54526 identifies a stack-based buffer overflow vulnerability (CWE-121) in Fuji Electric's Monitouch V-SFT-6, specifically version 6.2.7.0. This vulnerability arises during the processing of specially crafted project files, which can cause the software to overwrite memory on the stack, leading to arbitrary code execution. The flaw requires an attacker to deliver a malicious project file to a user who must then open or process it, implying user interaction is necessary. The CVSS 3.1 base score of 7.8 reflects a high severity, with an attack vector classified as local (AV:L), low attack complexity (AC:L), no privileges required (PR:N), and user interaction required (UI:R). The impact on confidentiality, integrity, and availability is high, as successful exploitation could allow an attacker to run arbitrary code within the context of the vulnerable application, potentially leading to control system compromise. No public exploits are currently known, but the vulnerability is significant given the critical role of Monitouch V-SFT-6 in industrial control environments. The lack of available patches at the time of publication necessitates immediate risk mitigation through operational controls. The vulnerability is particularly concerning for industrial control systems (ICS) and supervisory control and data acquisition (SCADA) environments where Monitouch HMIs are deployed, as exploitation could disrupt manufacturing processes or critical infrastructure operations.

Potential Impact

The vulnerability poses a serious risk to European organizations operating industrial control systems that utilize Fuji Electric Monitouch V-SFT-6. Successful exploitation could lead to arbitrary code execution, enabling attackers to manipulate or disrupt industrial processes, potentially causing physical damage, production downtime, or safety incidents. Confidentiality breaches could expose sensitive operational data, while integrity violations might alter control commands, leading to unsafe states. Availability impacts could result in system outages affecting manufacturing lines or critical infrastructure services. Given the local attack vector and requirement for user interaction, the threat is more likely to arise from insider threats or targeted spear-phishing campaigns delivering malicious project files. The high severity score underscores the need for urgent attention, especially in sectors such as manufacturing, energy, and utilities prevalent in Europe. Disruption in these sectors could have cascading economic and safety consequences.

Mitigation Recommendations

To mitigate this vulnerability, European organizations should: 1) Immediately restrict the import and use of project files from untrusted or unknown sources to prevent malicious file delivery. 2) Implement strict network segmentation to isolate HMI systems from general IT networks and limit exposure. 3) Enforce user training and awareness programs to reduce the risk of opening malicious project files. 4) Monitor and log HMI system activities to detect anomalous behavior indicative of exploitation attempts. 5) Apply vendor patches or updates as soon as they become available; maintain close communication with Fuji Electric for security advisories. 6) Employ application whitelisting and endpoint protection solutions on systems running Monitouch V-SFT-6 to prevent unauthorized code execution. 7) Conduct regular vulnerability assessments and penetration testing focused on industrial control environments to identify and remediate weaknesses proactively.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.2
Assigner Short Name
icscert
Date Reserved
2025-07-30T19:03:10.084Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 690a75ef9e609817bf78f742

Added to database: 11/4/2025, 9:53:51 PM

Last enriched: 11/4/2025, 10:09:24 PM

Last updated: 11/5/2025, 4:56:20 AM

Views: 8

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.