Skip to main content
CVE-2025-54563VulnerabilityPublished

CVE-2025-54563: n/a

Source CVE Database V5

0

Not known to be exploited · CVSS 7.5 High.

Data as of 25 Oct 2026, 19:02 UTC

CVSS 3.1 base score
7.5High
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.3% chance of exploitation in 30 days – higher than 30% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 24 Nov 2025

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 2026-10-25.

What to do

AI-suggested

Organizations should immediately inventory their use of Desktop Alert PingAlert to identify affected versions (6.1.0.11 to 6.1.1.2). Although no official patches are currently listed, they should monitor vendor advisories closely and apply updates as soon as they become available. In the interim, network-level mitigations such as restricting access to the application server to trusted IP ranges and implementing strict firewall rules can reduce exposure. Employing network segmentation to isolate the alerting system from general user networks limits potential attack vectors. Logging and monitoring access to the application server should be enhanced to detect anomalous or unauthorized queries indicative of exploitation attempts. Additionally, organizations should review and tighten access control policies within the application configuration to ensure least privilege principles are enforced. Conducting internal penetration testing focused on access control validation can help identify residual weaknesses. Finally, raising user and administrator awareness about this vulnerability will support timely detection and response.

Description

An Incorrect Access Control vulnerability was found in the Application Server of Desktop Alert PingAlert version 6.1.0.11 to 6.1.1.2 which allows Incorrect Access Control, leading to Remote Information Disclosure.

References

Community reviews

Loading reviews…