CVE-2025-56498: OS Command Injection
Source CVE Database V5
Not known to be exploited · CVSS 5.3 Medium.
Data as of 26 Oct 2026, 10:12 UTC
- EPSS
- 1.7% chance of exploitation in 30 days – higher than 77% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:NExploitation evidence
Disclosed: evidence found.
CVE published 3 Sep 2025
Detectable: no evidence on record.
No public nuclei template indexed
Weaponised: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.
What to do
AI-suggested
To mitigate this vulnerability, European organizations should first identify any deployment of the PLDT Prolink PGN6401V routers with Firmware 8.1.2 in their network. Immediate steps include restricting access to the router's web management interface to trusted administrators only, ideally through network segmentation and VPN access. Strong, unique passwords must be enforced to prevent unauthorized authentication. Monitoring and logging of administrative access attempts should be enhanced to detect suspicious activity. Since no official patches are currently available, organizations should consider temporary compensating controls such as disabling the vulnerable ping6.asp functionality if possible or replacing affected devices with updated models or firmware versions once available. Network-level protections like firewall rules can limit access to the router management interface from untrusted networks. Regular vulnerability scanning and penetration testing should be conducted to detect exploitation attempts. Finally, educating administrators about the risks of command injection and the importance of secure credential management is essential.
Description
An OS command injection vulnerability exists in PLDT WiFi Router's Prolink PGN6401V Firmware 8.1.2 web management interface. The ping6.asp page submits user input to the /boaform/formPing6 endpoint via the pingAddr parameter, which is not properly sanitized. An authenticated attacker can exploit this flaw by injecting arbitrary system commands, which are executed by the underlying operating system with root privileges. The router uses the Boa web server (version 0.93.15) to handle the request. Successful exploitation can lead to full system compromise and unauthorized control of the network device.