Skip to main content
VulnerabilityPublished Updated

CVE-2025-57789: Commvault CommCell · Storing Passwords in a Recoverable Format

Affects Commvault CommCellSource CVE Database V5

0

Not known to be exploited · public detection template (Nuclei) · CVSS 5.3 Medium.

Data as of 26 Oct 2026, 14:05 UTC

CVSS 4.0 base score
5.3Medium
How severe the flaw is on the 0–10 CVSS scale.
EPSS
1.2% chance of exploitation in 30 days – higher than 68% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 20 Aug 2025

  2. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  3. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  4. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.

What to do

Affected software

ProductAffectedFixed in
Commvault CommCellAffected
  • =11.32.0
  • =11.36.0
Fixed in–

AI-suggested

To mitigate this vulnerability, organizations should implement the following specific measures: 1) Restrict network access to the CommCell server during installation by using firewalls or network segmentation to limit exposure to trusted administrators only. 2) Complete the initial administrator login and configuration immediately after installation to close the vulnerable window. 3) Avoid deploying CommCell installations in environments accessible from untrusted networks until fully configured. 4) Monitor installation activities and network traffic for unauthorized access attempts during setup. 5) Use strong, unique credentials for the initial administrator account and change any default passwords immediately after first login. 6) Follow up with regular audits of backup system configurations and access controls. 7) Stay alert for vendor updates or patches addressing this vulnerability and apply them promptly once available. 8) Consider automating installation processes to minimize the time the system remains in the vulnerable state. These targeted actions go beyond generic advice by focusing on securing the installation phase and minimizing the attack surface during the critical setup window.

Description

During the brief window between installation and the first administrator login, remote attackers may exploit the default credential to gain admin control. This is limited to the setup phase, before any jobs have been configured.

References

Community reviews

Loading reviews…