CVE-2025-59171: CWE-22 in Advantech DeviceOn/iEdge
Due to insufficient sanitization, an attacker can upload a specially crafted configuration file to traverse directories and achieve remote code execution with system-level permissions.
AI Analysis
Technical Summary
CVE-2025-59171 is a vulnerability classified under CWE-22 (Improper Limitation of a Pathname to a Restricted Directory) affecting Advantech's DeviceOn/iEdge platform. The root cause is insufficient sanitization of user-supplied input during the upload of configuration files. An attacker can exploit this by crafting a malicious configuration file that includes directory traversal sequences (e.g., ../) to escape the intended upload directory. This allows overwriting or placing files outside the designated directory, potentially leading to remote code execution (RCE) with system-level privileges. The vulnerability requires no authentication and no user interaction, making it exploitable remotely over the network. The CVSS v3.1 base score of 7.5 reflects the ease of exploitation (low attack complexity), no privileges required, and high confidentiality impact, though integrity and availability impacts are not directly affected. The affected product, DeviceOn/iEdge, is used for industrial IoT device management and edge computing, which often operate in critical infrastructure environments. No patches or exploits are currently publicly available, but the vulnerability's nature suggests a high risk if weaponized. The lack of authentication and user interaction requirements significantly increase the threat surface, especially in environments where these devices are exposed to untrusted networks or insufficiently segmented internal networks.
Potential Impact
For European organizations, especially those in industrial automation, manufacturing, energy, and critical infrastructure sectors, this vulnerability poses a substantial risk. Successful exploitation could lead to unauthorized system-level code execution, potentially allowing attackers to manipulate device behavior, disrupt operations, or pivot to other network segments. Given the role of DeviceOn/iEdge in managing edge devices and IoT deployments, compromise could result in loss of control over critical industrial processes, data leakage, or sabotage. The high confidentiality impact means sensitive configuration and operational data could be exposed. The absence of required authentication and user interaction broadens the attack surface, increasing the likelihood of exploitation in environments where these devices are accessible remotely or insufficiently protected. This could lead to operational disruptions, financial losses, and safety hazards, particularly in sectors with stringent regulatory requirements such as energy and transportation.
Mitigation Recommendations
1. Immediately restrict network access to DeviceOn/iEdge management interfaces, ensuring they are not exposed to untrusted networks or the internet. 2. Implement strict input validation and sanitization on file upload mechanisms to prevent directory traversal sequences. 3. Employ application-layer firewalls or intrusion prevention systems to detect and block suspicious upload attempts containing traversal patterns. 4. Monitor logs and network traffic for anomalous file uploads or unexpected file system changes. 5. Use network segmentation to isolate DeviceOn/iEdge systems from general enterprise networks, limiting lateral movement. 6. Coordinate with Advantech for timely patch deployment once available; in the absence of patches, consider temporary disabling of file upload features if feasible. 7. Conduct regular security audits and penetration testing focused on file upload and configuration management functionalities. 8. Educate operational technology (OT) and IT teams about this vulnerability and ensure incident response plans include scenarios involving edge device compromise.
Affected Countries
Germany, France, Italy, United Kingdom, Netherlands, Belgium, Sweden, Finland
CVE-2025-59171: CWE-22 in Advantech DeviceOn/iEdge
Description
Due to insufficient sanitization, an attacker can upload a specially crafted configuration file to traverse directories and achieve remote code execution with system-level permissions.
AI-Powered Analysis
Technical Analysis
CVE-2025-59171 is a vulnerability classified under CWE-22 (Improper Limitation of a Pathname to a Restricted Directory) affecting Advantech's DeviceOn/iEdge platform. The root cause is insufficient sanitization of user-supplied input during the upload of configuration files. An attacker can exploit this by crafting a malicious configuration file that includes directory traversal sequences (e.g., ../) to escape the intended upload directory. This allows overwriting or placing files outside the designated directory, potentially leading to remote code execution (RCE) with system-level privileges. The vulnerability requires no authentication and no user interaction, making it exploitable remotely over the network. The CVSS v3.1 base score of 7.5 reflects the ease of exploitation (low attack complexity), no privileges required, and high confidentiality impact, though integrity and availability impacts are not directly affected. The affected product, DeviceOn/iEdge, is used for industrial IoT device management and edge computing, which often operate in critical infrastructure environments. No patches or exploits are currently publicly available, but the vulnerability's nature suggests a high risk if weaponized. The lack of authentication and user interaction requirements significantly increase the threat surface, especially in environments where these devices are exposed to untrusted networks or insufficiently segmented internal networks.
Potential Impact
For European organizations, especially those in industrial automation, manufacturing, energy, and critical infrastructure sectors, this vulnerability poses a substantial risk. Successful exploitation could lead to unauthorized system-level code execution, potentially allowing attackers to manipulate device behavior, disrupt operations, or pivot to other network segments. Given the role of DeviceOn/iEdge in managing edge devices and IoT deployments, compromise could result in loss of control over critical industrial processes, data leakage, or sabotage. The high confidentiality impact means sensitive configuration and operational data could be exposed. The absence of required authentication and user interaction broadens the attack surface, increasing the likelihood of exploitation in environments where these devices are accessible remotely or insufficiently protected. This could lead to operational disruptions, financial losses, and safety hazards, particularly in sectors with stringent regulatory requirements such as energy and transportation.
Mitigation Recommendations
1. Immediately restrict network access to DeviceOn/iEdge management interfaces, ensuring they are not exposed to untrusted networks or the internet. 2. Implement strict input validation and sanitization on file upload mechanisms to prevent directory traversal sequences. 3. Employ application-layer firewalls or intrusion prevention systems to detect and block suspicious upload attempts containing traversal patterns. 4. Monitor logs and network traffic for anomalous file uploads or unexpected file system changes. 5. Use network segmentation to isolate DeviceOn/iEdge systems from general enterprise networks, limiting lateral movement. 6. Coordinate with Advantech for timely patch deployment once available; in the absence of patches, consider temporary disabling of file upload features if feasible. 7. Conduct regular security audits and penetration testing focused on file upload and configuration management functionalities. 8. Educate operational technology (OT) and IT teams about this vulnerability and ensure incident response plans include scenarios involving edge device compromise.
Affected Countries
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- icscert
- Date Reserved
- 2025-11-05T16:45:22.619Z
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 690d258e790724a13ccd5548
Added to database: 11/6/2025, 10:47:42 PM
Last enriched: 11/6/2025, 10:52:26 PM
Last updated: 11/7/2025, 5:53:48 AM
Views: 9
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Related Threats
CVE-2025-64346: CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') in jaredallard archives
MediumCVE-2025-12527: CWE-862 Missing Authorization in yydevelopment Page & Post Notes
MediumCVE-2025-12520: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in jgwhite33 WP Airbnb Review Slider
MediumCVE-2025-64343: CWE-289: Authentication Bypass by Alternate Name in conda constructor
HighCVE-2025-64339: CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in MacWarrior clipbucket-v5
HighActions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.