CVE-2025-59461: CWE-862 Missing Authorization in SICK AG TLOC100-100 all Firmware versions
A remote unauthenticated attacker may use the unauthenticated C++ API to access or modify sensitive data and disrupt services.
AI Analysis
Technical Summary
CVE-2025-59461 is a vulnerability classified under CWE-862 (Missing Authorization) affecting all firmware versions of the SICK AG TLOC100-100 device. The flaw resides in the device's unauthenticated C++ API, which lacks proper authorization checks, allowing remote attackers to interact with the device without any authentication. This enables attackers to read or modify sensitive data and disrupt device services remotely. The vulnerability is exploitable over the network (Attack Vector: Adjacent Network), requires no privileges or user interaction, and affects confidentiality, integrity, and availability. The CVSS 3.1 base score of 7.6 reflects a high severity due to the ease of exploitation and significant impact on availability (high impact) and moderate impact on confidentiality and integrity (low impact). The device is commonly used in industrial automation and sensing applications, where reliable operation and data integrity are critical. No patches or mitigations have been officially released yet, and no known exploits have been observed in the wild. The vulnerability's presence in all firmware versions indicates a systemic design flaw in the API's authorization mechanism. Attackers exploiting this vulnerability could cause operational disruptions, data manipulation, or unauthorized data disclosure, potentially impacting industrial processes and safety systems.
Potential Impact
For European organizations, especially those in manufacturing, industrial automation, and critical infrastructure sectors, this vulnerability poses a significant risk. Exploitation could lead to unauthorized access to sensitive operational data, manipulation of device behavior, and disruption of automated processes, potentially causing production downtime, safety hazards, and financial losses. The high impact on availability could interrupt critical services, while the moderate impact on confidentiality and integrity could lead to data leakage or unauthorized changes to device configurations. Given the widespread use of SICK AG products in European industrial environments, the vulnerability could affect supply chains and operational continuity. The lack of authentication requirements lowers the barrier for attackers, increasing the likelihood of exploitation if devices are exposed to accessible networks. The absence of patches further elevates the risk until mitigations are implemented.
Mitigation Recommendations
1. Immediately isolate TLOC100-100 devices from untrusted or public networks by implementing strict network segmentation and firewall rules to restrict access to trusted management networks only. 2. Employ VPNs or secure tunnels for any remote access to these devices to ensure encrypted and authenticated communication channels. 3. Monitor network traffic for unusual or unauthorized API calls targeting the TLOC100-100 devices, using intrusion detection systems tailored to detect anomalous behavior in industrial protocols. 4. Implement strict access control policies at the network level, limiting which hosts can communicate with the devices. 5. Engage with SICK AG for updates or patches and subscribe to their security advisories to apply fixes promptly once available. 6. Conduct thorough audits of device configurations and logs to detect any signs of unauthorized access or manipulation. 7. Consider deploying compensating controls such as application-layer gateways or proxies that enforce authorization before forwarding requests to the vulnerable API. 8. Train operational technology (OT) and security teams to recognize and respond to potential exploitation attempts targeting these devices.
Affected Countries
Germany, France, Italy, Netherlands, Belgium, Poland, Sweden
CVE-2025-59461: CWE-862 Missing Authorization in SICK AG TLOC100-100 all Firmware versions
Description
A remote unauthenticated attacker may use the unauthenticated C++ API to access or modify sensitive data and disrupt services.
AI-Powered Analysis
Technical Analysis
CVE-2025-59461 is a vulnerability classified under CWE-862 (Missing Authorization) affecting all firmware versions of the SICK AG TLOC100-100 device. The flaw resides in the device's unauthenticated C++ API, which lacks proper authorization checks, allowing remote attackers to interact with the device without any authentication. This enables attackers to read or modify sensitive data and disrupt device services remotely. The vulnerability is exploitable over the network (Attack Vector: Adjacent Network), requires no privileges or user interaction, and affects confidentiality, integrity, and availability. The CVSS 3.1 base score of 7.6 reflects a high severity due to the ease of exploitation and significant impact on availability (high impact) and moderate impact on confidentiality and integrity (low impact). The device is commonly used in industrial automation and sensing applications, where reliable operation and data integrity are critical. No patches or mitigations have been officially released yet, and no known exploits have been observed in the wild. The vulnerability's presence in all firmware versions indicates a systemic design flaw in the API's authorization mechanism. Attackers exploiting this vulnerability could cause operational disruptions, data manipulation, or unauthorized data disclosure, potentially impacting industrial processes and safety systems.
Potential Impact
For European organizations, especially those in manufacturing, industrial automation, and critical infrastructure sectors, this vulnerability poses a significant risk. Exploitation could lead to unauthorized access to sensitive operational data, manipulation of device behavior, and disruption of automated processes, potentially causing production downtime, safety hazards, and financial losses. The high impact on availability could interrupt critical services, while the moderate impact on confidentiality and integrity could lead to data leakage or unauthorized changes to device configurations. Given the widespread use of SICK AG products in European industrial environments, the vulnerability could affect supply chains and operational continuity. The lack of authentication requirements lowers the barrier for attackers, increasing the likelihood of exploitation if devices are exposed to accessible networks. The absence of patches further elevates the risk until mitigations are implemented.
Mitigation Recommendations
1. Immediately isolate TLOC100-100 devices from untrusted or public networks by implementing strict network segmentation and firewall rules to restrict access to trusted management networks only. 2. Employ VPNs or secure tunnels for any remote access to these devices to ensure encrypted and authenticated communication channels. 3. Monitor network traffic for unusual or unauthorized API calls targeting the TLOC100-100 devices, using intrusion detection systems tailored to detect anomalous behavior in industrial protocols. 4. Implement strict access control policies at the network level, limiting which hosts can communicate with the devices. 5. Engage with SICK AG for updates or patches and subscribe to their security advisories to apply fixes promptly once available. 6. Conduct thorough audits of device configurations and logs to detect any signs of unauthorized access or manipulation. 7. Consider deploying compensating controls such as application-layer gateways or proxies that enforce authorization before forwarding requests to the vulnerable API. 8. Train operational technology (OT) and security teams to recognize and respond to potential exploitation attempts targeting these devices.
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- SICK AG
- Date Reserved
- 2025-09-16T13:38:29.663Z
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 68ff4972bbaf5d265c87717d
Added to database: 10/27/2025, 10:29:06 AM
Last enriched: 10/27/2025, 10:43:58 AM
Last updated: 10/27/2025, 12:11:38 PM
Views: 3
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Related Threats
CVE-2025-12272: Buffer Overflow in Tenda CH22
HighCVE-2025-12271: Buffer Overflow in Tenda CH22
HighCVE-2025-12270: Improper Control of Resource Identifiers in LearnHouse
MediumCVE-2025-41009: CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') in Disenno de Recursos Educativos S.L virtual campus platform
CriticalCVE-2025-12269: Cross Site Scripting in LearnHouse
MediumActions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.