CVE-2025-63214: n/a
An issue was discovered in bridgetech VBC Server & Element Manager, firmware version 6.5.0-10 , 6.5.0-9, allowing unauthorized attackers to delete and create arbitrary accounts.
AI Analysis
Technical Summary
CVE-2025-63214 is a security vulnerability identified in bridgetech VBC Server & Element Manager firmware versions 6.5.0-9 and 6.5.0-10. The flaw allows unauthorized attackers to perform account management operations, specifically the creation and deletion of arbitrary user accounts, without requiring any authentication or user interaction. This vulnerability is classified under CWE-284, which relates to improper access control. The CVSS v3.1 base score is 6.5, reflecting a medium severity level, with an attack vector of network (AV:N), low attack complexity (AC:L), no privileges required (PR:N), and no user interaction (UI:N). The scope is unchanged (S:U), with no confidentiality impact (C:N), but with low integrity (I:L) and availability (A:L) impacts. Exploiting this vulnerability could allow attackers to disrupt system operations by deleting legitimate accounts or establishing unauthorized accounts to maintain persistence or escalate privileges. Although no public exploits are currently known, the lack of authentication requirements and the ability to manipulate accounts remotely make this a significant risk. The absence of available patches at the time of reporting necessitates immediate mitigation through compensating controls. The vulnerability affects critical management components of bridgetech's industrial control and network management products, which are often deployed in operational technology environments.
Potential Impact
For European organizations, especially those in industrial sectors such as manufacturing, utilities, and critical infrastructure that utilize bridgetech VBC Server & Element Manager, this vulnerability poses a serious threat to operational integrity and availability. Unauthorized account creation and deletion can lead to unauthorized access, privilege escalation, and potential disruption of control systems. This could result in operational downtime, safety incidents, or data integrity issues. The ability to manipulate accounts without authentication increases the risk of insider-like attacks from external adversaries. Given the interconnected nature of industrial networks in Europe and the increasing targeting of OT environments by threat actors, exploitation could have cascading effects on supply chains and critical services. Organizations in Europe with deployments of affected firmware versions must consider the risk of targeted attacks, especially in countries with advanced industrial sectors and critical infrastructure dependencies.
Mitigation Recommendations
1. Immediately inventory all bridgetech VBC Server & Element Manager devices and verify firmware versions to identify affected systems. 2. Apply vendor patches or firmware updates as soon as they become available; monitor bridgetech advisories closely. 3. Implement strict network segmentation to isolate management interfaces from general network access, limiting exposure to untrusted networks. 4. Enforce access control lists (ACLs) and firewall rules to restrict access to management ports only to authorized personnel and systems. 5. Deploy continuous monitoring and logging of account management activities to detect unauthorized creation or deletion of accounts promptly. 6. Use multi-factor authentication (MFA) where possible on management interfaces to add an additional layer of security. 7. Conduct regular audits of user accounts and permissions to identify anomalies. 8. Consider deploying intrusion detection/prevention systems (IDS/IPS) tuned to detect suspicious activity targeting bridgetech management systems. 9. Train operational technology and IT security teams on this vulnerability and response procedures to ensure rapid incident handling.
Affected Countries
Germany, France, United Kingdom, Italy, Netherlands, Belgium, Sweden, Poland
CVE-2025-63214: n/a
Description
An issue was discovered in bridgetech VBC Server & Element Manager, firmware version 6.5.0-10 , 6.5.0-9, allowing unauthorized attackers to delete and create arbitrary accounts.
AI-Powered Analysis
Technical Analysis
CVE-2025-63214 is a security vulnerability identified in bridgetech VBC Server & Element Manager firmware versions 6.5.0-9 and 6.5.0-10. The flaw allows unauthorized attackers to perform account management operations, specifically the creation and deletion of arbitrary user accounts, without requiring any authentication or user interaction. This vulnerability is classified under CWE-284, which relates to improper access control. The CVSS v3.1 base score is 6.5, reflecting a medium severity level, with an attack vector of network (AV:N), low attack complexity (AC:L), no privileges required (PR:N), and no user interaction (UI:N). The scope is unchanged (S:U), with no confidentiality impact (C:N), but with low integrity (I:L) and availability (A:L) impacts. Exploiting this vulnerability could allow attackers to disrupt system operations by deleting legitimate accounts or establishing unauthorized accounts to maintain persistence or escalate privileges. Although no public exploits are currently known, the lack of authentication requirements and the ability to manipulate accounts remotely make this a significant risk. The absence of available patches at the time of reporting necessitates immediate mitigation through compensating controls. The vulnerability affects critical management components of bridgetech's industrial control and network management products, which are often deployed in operational technology environments.
Potential Impact
For European organizations, especially those in industrial sectors such as manufacturing, utilities, and critical infrastructure that utilize bridgetech VBC Server & Element Manager, this vulnerability poses a serious threat to operational integrity and availability. Unauthorized account creation and deletion can lead to unauthorized access, privilege escalation, and potential disruption of control systems. This could result in operational downtime, safety incidents, or data integrity issues. The ability to manipulate accounts without authentication increases the risk of insider-like attacks from external adversaries. Given the interconnected nature of industrial networks in Europe and the increasing targeting of OT environments by threat actors, exploitation could have cascading effects on supply chains and critical services. Organizations in Europe with deployments of affected firmware versions must consider the risk of targeted attacks, especially in countries with advanced industrial sectors and critical infrastructure dependencies.
Mitigation Recommendations
1. Immediately inventory all bridgetech VBC Server & Element Manager devices and verify firmware versions to identify affected systems. 2. Apply vendor patches or firmware updates as soon as they become available; monitor bridgetech advisories closely. 3. Implement strict network segmentation to isolate management interfaces from general network access, limiting exposure to untrusted networks. 4. Enforce access control lists (ACLs) and firewall rules to restrict access to management ports only to authorized personnel and systems. 5. Deploy continuous monitoring and logging of account management activities to detect unauthorized creation or deletion of accounts promptly. 6. Use multi-factor authentication (MFA) where possible on management interfaces to add an additional layer of security. 7. Conduct regular audits of user accounts and permissions to identify anomalies. 8. Consider deploying intrusion detection/prevention systems (IDS/IPS) tuned to detect suspicious activity targeting bridgetech management systems. 9. Train operational technology and IT security teams on this vulnerability and response procedures to ensure rapid incident handling.
Affected Countries
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- mitre
- Date Reserved
- 2025-10-27T00:00:00.000Z
- Cvss Version
- null
- State
- PUBLISHED
Threat ID: 691e248d4d0ffcb40bb0868a
Added to database: 11/19/2025, 8:11:57 PM
Last enriched: 11/26/2025, 9:04:57 PM
Last updated: 1/7/2026, 4:17:07 AM
Views: 29
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Related Threats
CVE-2026-20893: Origin validation error in Fujitsu Client Computing Limited Fujitsu Security Solution AuthConductor Client Basic V2
HighCVE-2025-14891: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in ivole Customer Reviews for WooCommerce
MediumCVE-2025-14059: CWE-73 External Control of File Name or Path in roxnor EmailKit – Email Customizer for WooCommerce & WP
MediumCVE-2025-12648: CWE-552 Files or Directories Accessible to External Parties in cbutlerjr WP-Members Membership Plugin
MediumCVE-2025-14631: CWE-476 NULL Pointer Dereference in TP-Link Systems Inc. Archer BE400
HighActions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
Need more coverage?
Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.