Skip to main content
CVE-2025-63512VulnerabilityPublished

CVE-2025-63512: n/a

Source CVE Database V5

0

Not known to be exploited · CVSS 6.5 Medium.

Data as of 26 Oct 2026, 06:26 UTC

CVSS 3.1 base score
6.5Medium
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.2% chance of exploitation in 30 days – higher than 16% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 18 Nov 2025

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 2026-10-26.

What to do

AI-suggested

To mitigate CVE-2025-63512, organizations should immediately review and update the affected Hospital Management System code to implement parameterized queries or prepared statements in place of dynamic SQL concatenation, particularly for the 'demail' parameter in admin-panel1.php. Input validation should be enforced to restrict inputs to expected formats, such as valid email addresses, reducing injection risk. If source code modification is not immediately feasible, deploying a Web Application Firewall (WAF) with rules targeting SQL Injection patterns can provide temporary protection. Restrict network access to the admin panel by implementing IP whitelisting or VPN-only access to reduce exposure. Database user accounts used by the application should have the least privileges necessary, preventing unauthorized data manipulation beyond what is required. Regularly audit database logs for suspicious queries indicative of injection attempts. Organizations should also conduct security assessments and penetration testing focused on injection vulnerabilities in all web-facing applications. Finally, maintain an inventory of all hospital management software versions in use to identify and prioritize vulnerable instances for patching or replacement. Coordination with software vendors for official patches or updates is recommended once available.

Description

CVE-2025-63512 is a medium-severity SQL Injection vulnerability found in the kishan0725 Hospital Management System v4, specifically in the admin-panel1.php file within the deleting doctor functionality. The vulnerability arises because the application does not properly sanitize or parameterize the 'demail' parameter before using it in a dynamic SQL query. This flaw allows unauthenticated remote attackers to inject malicious SQL commands, potentially leading to unauthorized data access or modification. Although no known exploits are currently reported in the wild, exploitation could compromise the confidentiality and integrity of sensitive healthcare data. The vulnerability requires no authentication or user interaction and can be exploited remotely over the network. European healthcare organizations using this system are at risk, especially those with limited security controls around legacy or niche hospital management software. Mitigation involves applying secure coding practices such as prepared statements and input validation, and monitoring for suspicious database activity. Countries with significant healthcare infrastructure and adoption of such systems, including Germany, France, Italy, Spain, and the UK, are most likely to be affected. Given the potential impact on sensitive patient data and ease of exploitation, timely remediation is critical.

References

Community reviews

Loading reviews…