Skip to main content

CVE-2025-6524: Improper Authentication in 70mai 1S

Low
VulnerabilityCVE-2025-6524cvecve-2025-6524
Published: Mon Jun 23 2025 (06/23/2025, 21:00:12 UTC)
Source: CVE Database V5
Vendor/Project: 70mai
Product: 1S

Description

A vulnerability classified as problematic has been found in 70mai 1S up to 20250611. This affects an unknown part of the component Video Services. The manipulation leads to improper authentication. Access to the local network is required for this attack to succeed. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

AI-Powered Analysis

AILast updated: 06/23/2025, 21:18:12 UTC

Technical Analysis

CVE-2025-6524 is a vulnerability identified in the 70mai 1S device, specifically affecting the Video Services component in versions up to 20250611. The core issue is improper authentication, which could potentially allow an attacker to bypass normal authentication mechanisms. However, exploitation of this vulnerability requires the attacker to have access to the local network, significantly limiting the attack surface. The attack complexity is rated as high, indicating that a successful exploit demands advanced skills or specific conditions. Additionally, the exploitability is considered difficult, and no user interaction or privileges are required to attempt exploitation. The vulnerability has been publicly disclosed, but the vendor has not responded or provided a patch as of the publication date. The CVSS 4.0 base score is 2.3, reflecting a low severity level primarily due to the limited impact on confidentiality, integrity, and availability, as well as the challenging exploitation conditions. The vulnerability does not affect system confidentiality, integrity, or availability significantly, and there is no indication of privilege escalation or remote exploitation without local network access. No known exploits are currently active in the wild, and no patches or mitigations have been officially released by the vendor.

Potential Impact

For European organizations, the impact of CVE-2025-6524 is relatively limited due to the low severity and the requirement for local network access. The vulnerability could potentially allow unauthorized access to video services on the affected 70mai 1S devices, which are primarily consumer-grade dashcams or similar video recording equipment. While this may not directly compromise critical enterprise infrastructure, it could lead to privacy breaches or unauthorized video data access if these devices are integrated into corporate or fleet management environments. The risk is higher in organizations that use 70mai 1S devices within their local networks, such as transportation companies or logistics providers. However, the high complexity and difficult exploitability reduce the likelihood of widespread exploitation. The lack of vendor response and patch availability means that affected organizations must rely on network-level controls and monitoring to mitigate risk. Overall, the threat is low but should not be ignored in environments where these devices are deployed and connected to sensitive networks.

Mitigation Recommendations

Segment the network to isolate 70mai 1S devices from critical infrastructure and sensitive data networks, minimizing the potential impact of unauthorized access. Implement strict local network access controls, including MAC address filtering and network access control (NAC) solutions, to limit which devices can communicate with the 70mai 1S devices. Monitor network traffic for unusual activity related to the Video Services component of the 70mai 1S, focusing on unauthorized connection attempts or abnormal data flows. Disable or restrict video service features on the 70mai 1S devices if they are not essential for operational purposes, reducing the attack surface. Maintain an inventory of all 70mai 1S devices within the organization and track firmware versions to identify and isolate vulnerable units. Engage with the vendor or community forums for updates or unofficial patches, and consider alternative devices if security support remains absent. Educate staff managing these devices about the vulnerability and the importance of network segmentation and access controls.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
VulDB
Date Reserved
2025-06-23T14:11:07.045Z
Cvss Version
4.0
State
PUBLISHED

Threat ID: 6859c3c943d9e1063349dc01

Added to database: 6/23/2025, 9:14:49 PM

Last enriched: 6/23/2025, 9:18:12 PM

Last updated: 6/23/2025, 9:24:44 PM

Views: 3

Actions

PRO

Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.