Skip to main content

CVE-2025-7988: CWE-787: Out-of-bounds Write in Ashlar-Vellum Graphite

High
VulnerabilityCVE-2025-7988cvecve-2025-7988cwe-787
Published: Wed Sep 17 2025 (09/17/2025, 20:52:33 UTC)
Source: CVE Database V5
Vendor/Project: Ashlar-Vellum
Product: Graphite

Description

Ashlar-Vellum Graphite VC6 File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Ashlar-Vellum Graphite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of VC6 files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-25862.

AI-Powered Analysis

AILast updated: 09/17/2025, 21:06:05 UTC

Technical Analysis

CVE-2025-7988 is a high-severity remote code execution vulnerability affecting Ashlar-Vellum Graphite version 13.0, a CAD software product. The vulnerability arises from an out-of-bounds write (CWE-787) during the parsing of VC6 files, a file format used by the application. Specifically, the software fails to properly validate user-supplied data when processing these files, leading to a write operation beyond the allocated buffer boundaries. This memory corruption can be exploited by an attacker to execute arbitrary code within the context of the current process. Exploitation requires user interaction, such as opening a maliciously crafted VC6 file or visiting a malicious web page that triggers the vulnerable parsing routine. The CVSS v3.0 base score is 7.8, indicating high severity, with attack vector local (AV:L), low attack complexity (AC:L), no privileges required (PR:N), and user interaction required (UI:R). The vulnerability impacts confidentiality, integrity, and availability, as arbitrary code execution can lead to full system compromise. No public exploits are currently known in the wild, and no patches have been published yet. The vulnerability was reserved in July 2025 and published in September 2025 by the Zero Day Initiative (ZDI) under the identifier ZDI-CAN-25862.

Potential Impact

For European organizations using Ashlar-Vellum Graphite 13.0, this vulnerability poses a significant risk. Successful exploitation can lead to arbitrary code execution, allowing attackers to install malware, steal sensitive design data, disrupt operations, or move laterally within networks. Given that Graphite is used in design and engineering workflows, compromised systems could result in intellectual property theft or sabotage of critical design files. The requirement for user interaction means phishing or social engineering campaigns could be used to deliver malicious VC6 files or lure users to malicious websites. This risk is heightened in sectors such as manufacturing, aerospace, automotive, and engineering firms prevalent in Europe, where CAD software is integral. The lack of available patches increases exposure, necessitating immediate mitigation. Additionally, the vulnerability could be leveraged in targeted attacks against organizations with valuable design assets, impacting confidentiality and operational continuity.

Mitigation Recommendations

1. Immediately restrict or disable the opening of VC6 files in Ashlar-Vellum Graphite 13.0 until a patch is available. 2. Implement strict email and web filtering to block or quarantine VC6 files and suspicious links that could deliver malicious payloads. 3. Educate users on the risks of opening unsolicited files or clicking unknown links, emphasizing the need for caution with VC6 files. 4. Employ application whitelisting and sandboxing techniques to limit the execution context of Graphite and contain potential exploitation. 5. Monitor endpoint and network activity for anomalous behaviors indicative of exploitation attempts, such as unexpected process launches or memory corruption indicators. 6. Coordinate with Ashlar-Vellum for timely patch deployment once available and apply updates promptly. 7. Consider network segmentation to isolate systems running Graphite from critical infrastructure to limit lateral movement. 8. Maintain up-to-date backups of design files and system states to enable recovery in case of compromise.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
zdi
Date Reserved
2025-07-21T19:49:51.895Z
Cvss Version
3.0
State
PUBLISHED

Threat ID: 68cb20e9c138e352740b9f65

Added to database: 9/17/2025, 8:58:17 PM

Last enriched: 9/17/2025, 9:06:05 PM

Last updated: 9/17/2025, 9:06:05 PM

Views: 2

Actions

PRO

Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.

Latest Threats