Skip to main content
VulnerabilityPublished

CVE-2025-9177: Rockwell Automation 1715-AENTR EtherNet/IP Adapter · Unthrottled Resource Allocation

Affects Rockwell Automation 1715-AENTR EtherNet/IP AdapterSource CVE Database V5

0

Not known to be exploited · CVSS 7.7 High.

Data as of 26 Oct 2026, 17:16 UTC

CVSS 4.0 base score
7.7High
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.3% chance of exploitation in 30 days – higher than 24% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:N/SC:N/SI:N/SA:H

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 14 Oct 2025

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.

What to do

Affected software

ProductAffectedFixed in
Rockwell Automation 1715-AENTR EtherNet/IP AdapterAffected
  • <=3.003
Fixed in–

AI-suggested

  1. Implement strict network segmentation to isolate the 1715-AENTR EtherNet/IP Adapter's management interface from general enterprise and internet-facing networks.
  2. Deploy network-level rate limiting and traffic shaping controls to detect and block excessive request volumes targeting the device's web server port.
  3. Use intrusion detection/prevention systems (IDS/IPS) with signatures or anomaly detection tuned to identify unusual traffic patterns against the adapter.
  4. Restrict access to the web management interface to trusted IP addresses or VPN connections only, minimizing exposure to unauthorized actors.
  5. Monitor device logs and network traffic for signs of repeated or abnormal connection attempts to the web server.
  6. Establish operational procedures to perform timely power cycles if the web interface becomes unresponsive, ensuring minimal disruption.
  7. Engage with Rockwell Automation support channels to obtain firmware updates or patches once available and plan for prompt deployment.
  8. Consider alternative management methods or redundant monitoring solutions to maintain visibility if the web interface is unavailable.
  9. Educate operational technology (OT) staff about this vulnerability and the importance of maintaining strict access controls.
  10. Regularly review and update network architecture to reduce attack surface exposure of critical industrial devices.

Description

A denial-of-service security issue exists in the affected product and version. The security issue stems from a high number of requests sent to the web server. This could result in a web server crash however; this does not impact I/O control or communication . A power cycle is required to recover and utilize the webpage.

References

Community reviews