CVE-2025-9313: CWE-288: Authentication Bypass Using an Alternate Path or Channel in Asseco Poland S.A. mMedica
An unauthenticated user can connect to a publicly accessible database using arbitrary credentials. The system grants full access to the database by leveraging a previously authenticated connection through a "mmBackup" application. This flaw allows attackers to bypass authentication mechanisms and gain unauthorized access to database with sensitive data. This issue affects Asseco mMedica in versions before 11.9.5.
AI Analysis
Technical Summary
CVE-2025-9313 is an authentication bypass vulnerability categorized under CWE-288, affecting Asseco Poland S.A.'s mMedica healthcare software versions before 11.9.5. The flaw arises because the system allows unauthenticated users to connect to a publicly accessible database by exploiting an alternate path through the 'mmBackup' application, which maintains a previously authenticated session. This alternate channel bypasses normal authentication controls, granting attackers full access to the database containing sensitive patient and healthcare data. The vulnerability is remotely exploitable without any authentication or user interaction, making it highly accessible to attackers. The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N) indicates network attack vector, low complexity, no privileges or user interaction required, and high impact on confidentiality, integrity, and availability. The lack of segmentation or proper access controls between backup processes and live database connections is a key technical root cause. Although no public exploits are reported yet, the critical nature of this flaw and the sensitivity of healthcare data make it a significant threat. The vulnerability was reserved in August 2025 and published in October 2025, with no official patches linked yet, emphasizing the need for immediate mitigation steps.
Potential Impact
For European organizations, particularly healthcare providers using mMedica, this vulnerability poses a severe risk of unauthorized data access, potentially exposing sensitive patient records and violating data protection regulations such as GDPR. The full database access could lead to data theft, manipulation, or deletion, disrupting healthcare services and undermining patient trust. The critical impact on confidentiality, integrity, and availability could result in operational downtime, regulatory penalties, and reputational damage. Given the healthcare sector's strategic importance and the sensitivity of medical data, exploitation could also have broader societal implications. The vulnerability's ease of exploitation and lack of required authentication increase the likelihood of attacks, especially in countries with significant deployments of Asseco mMedica. Additionally, attackers could leverage this access to pivot within networks, escalating the threat beyond the initial compromise.
Mitigation Recommendations
Organizations should immediately verify if they are running affected versions of mMedica (prior to 11.9.5) and prioritize upgrading to the latest secure version once available. Until patches are released, restrict network access to the database and the 'mmBackup' application by implementing strict firewall rules and network segmentation to isolate backup services from public networks. Employ intrusion detection and prevention systems to monitor unusual database connection attempts, especially those originating externally. Review and harden authentication mechanisms around backup processes to prevent unauthorized reuse of authenticated sessions. Conduct thorough audits of backup and database access logs to detect potential exploitation attempts. Engage with Asseco Poland S.A. for any available interim fixes or workarounds. Additionally, ensure that sensitive data is encrypted at rest and in transit to mitigate data exposure risks in case of unauthorized access. Regularly train IT and security staff on this vulnerability and response procedures.
Affected Countries
Poland, Germany, France, Italy, Spain, Netherlands, Belgium
CVE-2025-9313: CWE-288: Authentication Bypass Using an Alternate Path or Channel in Asseco Poland S.A. mMedica
Description
An unauthenticated user can connect to a publicly accessible database using arbitrary credentials. The system grants full access to the database by leveraging a previously authenticated connection through a "mmBackup" application. This flaw allows attackers to bypass authentication mechanisms and gain unauthorized access to database with sensitive data. This issue affects Asseco mMedica in versions before 11.9.5.
AI-Powered Analysis
Technical Analysis
CVE-2025-9313 is an authentication bypass vulnerability categorized under CWE-288, affecting Asseco Poland S.A.'s mMedica healthcare software versions before 11.9.5. The flaw arises because the system allows unauthenticated users to connect to a publicly accessible database by exploiting an alternate path through the 'mmBackup' application, which maintains a previously authenticated session. This alternate channel bypasses normal authentication controls, granting attackers full access to the database containing sensitive patient and healthcare data. The vulnerability is remotely exploitable without any authentication or user interaction, making it highly accessible to attackers. The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N) indicates network attack vector, low complexity, no privileges or user interaction required, and high impact on confidentiality, integrity, and availability. The lack of segmentation or proper access controls between backup processes and live database connections is a key technical root cause. Although no public exploits are reported yet, the critical nature of this flaw and the sensitivity of healthcare data make it a significant threat. The vulnerability was reserved in August 2025 and published in October 2025, with no official patches linked yet, emphasizing the need for immediate mitigation steps.
Potential Impact
For European organizations, particularly healthcare providers using mMedica, this vulnerability poses a severe risk of unauthorized data access, potentially exposing sensitive patient records and violating data protection regulations such as GDPR. The full database access could lead to data theft, manipulation, or deletion, disrupting healthcare services and undermining patient trust. The critical impact on confidentiality, integrity, and availability could result in operational downtime, regulatory penalties, and reputational damage. Given the healthcare sector's strategic importance and the sensitivity of medical data, exploitation could also have broader societal implications. The vulnerability's ease of exploitation and lack of required authentication increase the likelihood of attacks, especially in countries with significant deployments of Asseco mMedica. Additionally, attackers could leverage this access to pivot within networks, escalating the threat beyond the initial compromise.
Mitigation Recommendations
Organizations should immediately verify if they are running affected versions of mMedica (prior to 11.9.5) and prioritize upgrading to the latest secure version once available. Until patches are released, restrict network access to the database and the 'mmBackup' application by implementing strict firewall rules and network segmentation to isolate backup services from public networks. Employ intrusion detection and prevention systems to monitor unusual database connection attempts, especially those originating externally. Review and harden authentication mechanisms around backup processes to prevent unauthorized reuse of authenticated sessions. Conduct thorough audits of backup and database access logs to detect potential exploitation attempts. Engage with Asseco Poland S.A. for any available interim fixes or workarounds. Additionally, ensure that sensitive data is encrypted at rest and in transit to mitigate data exposure risks in case of unauthorized access. Regularly train IT and security staff on this vulnerability and response procedures.
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- CERT-PL
- Date Reserved
- 2025-08-21T07:29:05.144Z
- Cvss Version
- 4.0
- State
- PUBLISHED
Threat ID: 6900aee0930605802632913a
Added to database: 10/28/2025, 11:54:08 AM
Last enriched: 10/28/2025, 12:01:50 PM
Last updated: 10/28/2025, 2:09:49 PM
Views: 6
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Related Threats
CVE-2025-53855: CWE-787: Out-of-bounds Write in GCC Productions Inc. Fade In
HighCVE-2025-53814: CWE-416: Use After Free in GCC Productions Inc. Fade In
HighCVE-2025-12390: Session Fixation in Red Hat Red Hat Build of Keycloak
MediumCVE-2025-12103: Incorrect Privilege Assignment in Red Hat Red Hat OpenShift AI (RHOAI)
MediumCVE-2025-1038: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in Hitachi Energy TropOS 4th Gen
HighActions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.