CVE-2025-9437: Rockwell Automation ArmorStart AOP · Improper Handling of Exceptional Conditions
Affects Rockwell Automation ArmorStart AOPSource CVE Database V5
Not known to be exploited · CVSS 8.7 High.
Data as of 26 Oct 2026, 17:16 UTC
- EPSS
- 0.3% chance of exploitation in 30 days – higher than 30% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:NExploitation evidence
Disclosed: evidence found.
CVE published 14 Oct 2025
Detectable: no evidence on record.
No public nuclei template indexed
Weaponised: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.
What to do
Affected software
| Product | Affected | Fixed in |
|---|---|---|
| Rockwell Automation ArmorStart AOP | Affected
| Fixed in– |
AI-suggested
- Monitor Rockwell Automation advisories closely and apply official patches or updates for ArmorStart AOP as soon as they become available.
- Implement strict network segmentation to isolate industrial control systems and restrict access to the Studio 5000 Logix Designer environment and ArmorStart controllers.
- Employ firewall rules and intrusion detection/prevention systems to block unauthorized or malformed COM method calls targeting the ArmorStart AOP.
- Conduct input validation and anomaly detection on data sent to COM interfaces to detect and prevent invalid inputs that could trigger the DoS condition.
- Limit administrative access to the affected systems to trusted personnel only and enforce multi-factor authentication where possible.
- Develop and test incident response plans specific to industrial control system disruptions to minimize downtime if exploitation occurs.
- Perform regular security audits and vulnerability assessments on industrial automation environments to identify and remediate similar weaknesses proactively.
Description
A security issue exists within the Studio 5000 Logix Designer add-on profile (AOP) for the ArmorStart Classic distributed motor controller, resulting in denial-of-service. This vulnerability is possible due to the input of invalid values into Component Object Model (COM) methods.