Skip to main content

CVE-2025-9586: Command Injection in Comfast CF-N1

Medium
VulnerabilityCVE-2025-9586cvecve-2025-9586
Published: Thu Aug 28 2025 (08/28/2025, 21:02:05 UTC)
Source: CVE Database V5
Vendor/Project: Comfast
Product: CF-N1

Description

A vulnerability was identified in Comfast CF-N1 2.6.0. This vulnerability affects the function wireless_device_dissoc of the file /usr/bin/webmgnt. Such manipulation of the argument mac leads to command injection. The attack may be performed from a remote location. The exploit is publicly available and might be used.

AI-Powered Analysis

AILast updated: 08/28/2025, 21:32:47 UTC

Technical Analysis

CVE-2025-9586 is a command injection vulnerability identified in the Comfast CF-N1 wireless device, specifically affecting version 2.6.0. The flaw resides in the wireless_device_dissoc function within the /usr/bin/webmgnt binary. This function improperly handles the 'mac' argument, allowing an attacker to inject arbitrary commands. Because the vulnerability can be exploited remotely without requiring user interaction or authentication, it presents a significant risk. The vulnerability's CVSS 4.0 base score is 5.3 (medium severity), reflecting that it is remotely exploitable with low attack complexity and no privileges or user interaction required. The impact on confidentiality, integrity, and availability is limited but present, as the vulnerability allows partial control over the device through command injection. Although no public exploits are currently known to be actively used in the wild, the exploit code is publicly available, increasing the likelihood of exploitation attempts. The absence of a patch or mitigation guidance from the vendor at this time further elevates the risk. The Comfast CF-N1 is a wireless networking device commonly deployed in small to medium enterprise and residential environments, often used to manage wireless connections. Exploitation could allow attackers to disrupt wireless connectivity, execute arbitrary commands on the device, and potentially pivot into internal networks, depending on network segmentation and device placement. The vulnerability's presence in a network management binary increases the risk of network disruption or unauthorized network access if exploited.

Potential Impact

For European organizations, the impact of CVE-2025-9586 could be significant, particularly for those relying on Comfast CF-N1 devices in their network infrastructure. Exploitation could lead to unauthorized command execution on these devices, potentially disrupting wireless network availability and integrity. This could affect business continuity, especially in environments where wireless connectivity is critical for operations. Furthermore, attackers could leverage this vulnerability to gain a foothold within internal networks, leading to further lateral movement and data breaches. The medium severity rating suggests that while the vulnerability is not critical, it still poses a tangible risk, especially in sectors with high dependency on wireless networking such as telecommunications, manufacturing, and public services. The lack of authentication requirement and remote exploitability increases the threat surface, making it easier for attackers to target vulnerable devices across organizational boundaries. Additionally, the public availability of exploit code lowers the barrier for exploitation by less sophisticated threat actors, increasing the likelihood of opportunistic attacks.

Mitigation Recommendations

Given the absence of an official patch, European organizations should implement immediate compensating controls to mitigate the risk. These include: 1) Isolating Comfast CF-N1 devices on dedicated network segments with strict access controls to limit exposure to untrusted networks. 2) Implementing network-level filtering to restrict access to the device management interface only to trusted IP addresses or VPN users. 3) Monitoring network traffic for unusual command injection patterns or unexpected device behavior indicative of exploitation attempts. 4) Regularly auditing device firmware versions and configurations to identify and inventory vulnerable devices. 5) Engaging with Comfast support channels to obtain any available firmware updates or security advisories. 6) Considering temporary replacement or removal of vulnerable devices from critical network paths until a patch is available. 7) Employing intrusion detection/prevention systems (IDS/IPS) with signatures tuned to detect command injection attempts targeting the wireless_device_dissoc function. These targeted mitigations go beyond generic advice by focusing on network segmentation, access control, and active monitoring specific to the vulnerability's characteristics.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
VulDB
Date Reserved
2025-08-28T12:20:49.169Z
Cvss Version
4.0
State
PUBLISHED

Threat ID: 68b0c77dad5a09ad006fae93

Added to database: 8/28/2025, 9:17:49 PM

Last enriched: 8/28/2025, 9:32:47 PM

Last updated: 8/28/2025, 9:32:47 PM

Views: 2

Actions

PRO

Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.

Latest Threats