CVE-2026-28253: Trane Tracer SC · Excessive Memory Allocation
Affects Trane Tracer SCSource CVE Database V5
Not known to be exploited · CVSS 8.7 High : upgrade to v4.4 SP7 soon.
Data as of 30 Oct 2026, 06:59 UTC
- EPSS
- 0.3% chance of exploitation in 30 days – higher than 24% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
- Patch
- Available – fixed in v4.4 SP7, v6.3.2310
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:NExploitation evidence
Disclosed: evidence found.
CVE published 12 Mar 2026
Detectable: no evidence on record.
No public nuclei template indexed
Weaponized: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 29 Oct 2026.
What to do
Upgrade Tracer to v4.4 SP7 (SC) or v6.3.2310 (SC+, Concierge).
Affected software
| Product | Affected | Fixed in |
|---|---|---|
| TraneTracer SC | Affected
| Fixed in
|
| TraneTracer SC+ | Affected
| Fixed in
|
| TraneTracer Concierge | Affected
| Fixed in
|
AI-suggested
- Implement network-level access controls to restrict exposure of Trane Tracer SC systems to untrusted networks, including segmentation and firewall rules limiting inbound traffic to trusted sources only.
- Monitor network traffic for anomalous or excessive memory allocation requests targeting Trane systems, using IDS/IPS solutions with custom signatures if possible.
- Employ rate limiting or connection throttling on interfaces exposed to external networks to reduce the risk of resource exhaustion attacks.
- 5. Conduct regular system and network audits to identify and isolate vulnerable Trane devices, prioritizing remediation or temporary isolation. 6. Consider deploying application-layer gateways or proxies that can validate and sanitize incoming requests to Trane systems, preventing malformed or oversized allocation requests. 7. Develop incident response plans specific to building management system disruptions to ensure rapid recovery and mitigation of DoS events. 8. Where possible, implement redundancy and failover mechanisms for critical building management functions to maintain availability during attacks.
Description
CVE-2026-28253 is a high-severity vulnerability in Trane Tracer SC, Tracer SC+, and Tracer Concierge building management systems. It involves a memory allocation flaw where an attacker can request excessive memory allocation, leading to denial-of-service (DoS) conditions. The vulnerability requires no authentication or user interaction and can be exploited remotely over the network. While no known exploits are currently in the wild, the CVSS score of 8.7 reflects the significant risk posed by this flaw. The vulnerability impacts availability by potentially crashing or severely degrading the affected systems. Trane Tracer products are widely used in commercial and industrial HVAC and building automation, making this a critical concern for organizations relying on these systems. Mitigation requires careful input validation and memory allocation controls, though no patches are currently available. Countries with extensive deployment of Trane building management solutions and critical infrastructure reliance on such systems are at higher risk. Immediate defensive measures and monitoring are recommended to prevent exploitation.