CVE-2026-29127: CWE-269 Improper Privilege Management in International Datacasting Corporation SFX2100 Satellite Receiver
CVE-2026-29127 is a critical vulnerability in the International Datacasting Corporation SFX2100 Satellite Receiver caused by overly permissive file system permissions (0777) on the monitor user's home directory. This misconfiguration allows any local user on the system to read, write, and execute files within this directory. Because highly privileged processes and binaries reside there, an attacker with local access can potentially escalate privileges to gain elevated control over the device. The vulnerability requires local access but no user interaction and has a high impact on confidentiality, integrity, and availability. No known exploits are currently in the wild. Organizations using the SFX2100 should urgently review and restrict directory permissions to prevent exploitation. This issue primarily affects environments where these satellite receivers are deployed, including critical infrastructure and broadcast organizations worldwide.
AI Analysis
Technical Summary
CVE-2026-29127 identifies an improper privilege management vulnerability (CWE-269) in the International Datacasting Corporation SFX2100 Satellite Receiver. The root cause is the assignment of overly permissive file system permissions (mode 0777) on the monitor user's home directory. This permission setting grants read, write, and execute access to all local users on the system, which is a significant security misconfiguration. The presence of highly privileged processes and binaries within this directory means that a local attacker can manipulate these files to escalate privileges, potentially gaining administrative or root-level control over the device. The vulnerability does not require user interaction but does require local access, which could be obtained by an insider threat or through other means of local compromise. The CVSS v4.0 score of 9.2 reflects the critical nature of this vulnerability, highlighting its high impact on confidentiality, integrity, and availability, as well as the ease of exploitation given low attack complexity and no need for authentication beyond local access. Although no known exploits have been reported in the wild, the vulnerability poses a serious risk to organizations relying on the SFX2100 for satellite data reception and broadcasting. The lack of available patches at the time of publication necessitates immediate mitigation through configuration changes and access control hardening.
Potential Impact
The vulnerability enables local privilege escalation, allowing an attacker with local access to gain elevated privileges on the SFX2100 device. This can lead to unauthorized access to sensitive satellite data streams, manipulation or disruption of broadcast content, and potential control over the device's operations. The compromise of such satellite receivers could impact critical communications infrastructure, broadcasting services, and data distribution networks. The high severity and critical CVSS score indicate that exploitation could severely affect confidentiality, integrity, and availability of the system. Organizations operating these devices risk operational disruption, data leakage, and potential use of the compromised device as a foothold for further network intrusion. Given the specialized nature of the product, the impact is concentrated but significant in sectors reliant on satellite data transmission and reception.
Mitigation Recommendations
Immediate mitigation should focus on correcting the file system permissions on the monitor user's home directory to restrict access to only the necessary privileged users, ideally setting permissions to 0700 or similarly restrictive modes. Organizations should audit all SFX2100 devices to identify affected systems and apply configuration changes promptly. Implement strict local user access controls and monitor for unauthorized local access attempts. If possible, isolate the devices within secure network segments to limit local access vectors. Regularly review and harden device configurations, including disabling unnecessary services and removing or restricting access to privileged binaries within user directories. Until an official patch is released, consider deploying host-based intrusion detection systems to alert on suspicious file modifications or privilege escalations. Engage with the vendor for updates and patches and plan for timely deployment once available.
Affected Countries
United States, Canada, United Kingdom, Australia, Germany, France, Japan, South Korea, India, Brazil, United Arab Emirates
CVE-2026-29127: CWE-269 Improper Privilege Management in International Datacasting Corporation SFX2100 Satellite Receiver
Description
CVE-2026-29127 is a critical vulnerability in the International Datacasting Corporation SFX2100 Satellite Receiver caused by overly permissive file system permissions (0777) on the monitor user's home directory. This misconfiguration allows any local user on the system to read, write, and execute files within this directory. Because highly privileged processes and binaries reside there, an attacker with local access can potentially escalate privileges to gain elevated control over the device. The vulnerability requires local access but no user interaction and has a high impact on confidentiality, integrity, and availability. No known exploits are currently in the wild. Organizations using the SFX2100 should urgently review and restrict directory permissions to prevent exploitation. This issue primarily affects environments where these satellite receivers are deployed, including critical infrastructure and broadcast organizations worldwide.
AI-Powered Analysis
Technical Analysis
CVE-2026-29127 identifies an improper privilege management vulnerability (CWE-269) in the International Datacasting Corporation SFX2100 Satellite Receiver. The root cause is the assignment of overly permissive file system permissions (mode 0777) on the monitor user's home directory. This permission setting grants read, write, and execute access to all local users on the system, which is a significant security misconfiguration. The presence of highly privileged processes and binaries within this directory means that a local attacker can manipulate these files to escalate privileges, potentially gaining administrative or root-level control over the device. The vulnerability does not require user interaction but does require local access, which could be obtained by an insider threat or through other means of local compromise. The CVSS v4.0 score of 9.2 reflects the critical nature of this vulnerability, highlighting its high impact on confidentiality, integrity, and availability, as well as the ease of exploitation given low attack complexity and no need for authentication beyond local access. Although no known exploits have been reported in the wild, the vulnerability poses a serious risk to organizations relying on the SFX2100 for satellite data reception and broadcasting. The lack of available patches at the time of publication necessitates immediate mitigation through configuration changes and access control hardening.
Potential Impact
The vulnerability enables local privilege escalation, allowing an attacker with local access to gain elevated privileges on the SFX2100 device. This can lead to unauthorized access to sensitive satellite data streams, manipulation or disruption of broadcast content, and potential control over the device's operations. The compromise of such satellite receivers could impact critical communications infrastructure, broadcasting services, and data distribution networks. The high severity and critical CVSS score indicate that exploitation could severely affect confidentiality, integrity, and availability of the system. Organizations operating these devices risk operational disruption, data leakage, and potential use of the compromised device as a foothold for further network intrusion. Given the specialized nature of the product, the impact is concentrated but significant in sectors reliant on satellite data transmission and reception.
Mitigation Recommendations
Immediate mitigation should focus on correcting the file system permissions on the monitor user's home directory to restrict access to only the necessary privileged users, ideally setting permissions to 0700 or similarly restrictive modes. Organizations should audit all SFX2100 devices to identify affected systems and apply configuration changes promptly. Implement strict local user access controls and monitor for unauthorized local access attempts. If possible, isolate the devices within secure network segments to limit local access vectors. Regularly review and harden device configurations, including disabling unnecessary services and removing or restricting access to privileged binaries within user directories. Until an official patch is released, consider deploying host-based intrusion detection systems to alert on suspicious file modifications or privilege escalations. Engage with the vendor for updates and patches and plan for timely deployment once available.
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- Gridware
- Date Reserved
- 2026-03-04T07:53:45.786Z
- Cvss Version
- 4.0
- State
- PUBLISHED
Threat ID: 69a8f5fbd1a09e29cbacc596
Added to database: 3/5/2026, 3:18:19 AM
Last enriched: 3/5/2026, 3:32:34 AM
Last updated: 3/5/2026, 5:31:45 AM
Views: 6
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Related Threats
CVE-2026-3523: CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') in blobfolio Apocalypse Meow
MediumCVE-2026-3034: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in sagarpatel124 OoohBoi Steroids for Elementor
MediumCVE-2026-2899: CWE-862 Missing Authorization in techjewel Fluent Forms Pro Add On Pack
MediumCVE-2026-2365: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in techjewel Fluent Forms Pro Add On Pack
HighCVE-2026-26034: Incorrect default permissions in Dell Inc. UPS Multi-UPS Management Console (MUMC)
HighActions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
External Links
Need more coverage?
Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.
Latest Threats
Check if your credentials are on the dark web
Instant breach scanning across billions of leaked records. Free tier available.