CVE-2026-50062: CWE-125: Out-of-bounds Read in Siemens Solid Edge SE2025
An out-of-bounds read vulnerability exists in Siemens Solid Edge SE2025 and SE2026 when parsing specially crafted PAR files. This flaw affects all versions of SE2025 prior to V225.0 Update 15 and SE2026 prior to V226.0 Update 7. Exploitation could allow code execution within the context of the current process. The vulnerability has a high severity rating with a CVSS score of 7.8. No official patch or remediation guidance is currently confirmed.
AI Analysis
Technical Summary
CVE-2026-50062 is an out-of-bounds read vulnerability (CWE-125) in Siemens Solid Edge SE2025 and SE2026. It occurs during parsing of specially crafted PAR files, potentially enabling an attacker to execute arbitrary code in the context of the affected process. The affected versions are all SE2025 versions before V225.0 Update 15 and all SE2026 versions before V226.0 Update 7. The vulnerability has a CVSS 3.1 base score of 7.8, indicating high impact on confidentiality, integrity, and availability. No vendor advisory or patch information is currently available to confirm remediation status.
Potential Impact
Successful exploitation could lead to arbitrary code execution with the privileges of the current user process, impacting confidentiality, integrity, and availability of the affected system. The vulnerability arises from an out-of-bounds read during file parsing, which may be leveraged by an attacker to execute malicious code.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is released, avoid opening untrusted PAR files with affected versions of Solid Edge SE2025 and SE2026.
CVE-2026-50062: CWE-125: Out-of-bounds Read in Siemens Solid Edge SE2025
Description
An out-of-bounds read vulnerability exists in Siemens Solid Edge SE2025 and SE2026 when parsing specially crafted PAR files. This flaw affects all versions of SE2025 prior to V225.0 Update 15 and SE2026 prior to V226.0 Update 7. Exploitation could allow code execution within the context of the current process. The vulnerability has a high severity rating with a CVSS score of 7.8. No official patch or remediation guidance is currently confirmed.
CVSS v3.1
Score 7.8high
Weaknesses
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
CVE-2026-50062 is an out-of-bounds read vulnerability (CWE-125) in Siemens Solid Edge SE2025 and SE2026. It occurs during parsing of specially crafted PAR files, potentially enabling an attacker to execute arbitrary code in the context of the affected process. The affected versions are all SE2025 versions before V225.0 Update 15 and all SE2026 versions before V226.0 Update 7. The vulnerability has a CVSS 3.1 base score of 7.8, indicating high impact on confidentiality, integrity, and availability. No vendor advisory or patch information is currently available to confirm remediation status.
Potential Impact
Successful exploitation could lead to arbitrary code execution with the privileges of the current user process, impacting confidentiality, integrity, and availability of the affected system. The vulnerability arises from an out-of-bounds read during file parsing, which may be leveraged by an attacker to execute malicious code.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is released, avoid opening untrusted PAR files with affected versions of Solid Edge SE2025 and SE2026.
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- siemens
- Date Reserved
- 2026-06-03T11:07:02.668Z
- Cvss Version
- 3.1
- State
- PUBLISHED
- Remediation Level
- null
Threat ID: 6a7b18a0bf8831d539b860b2
Added to database: 08/11/2026, 12:42:08 UTC
Last enriched: 08/11/2026, 13:00:04 UTC
Last updated: 08/12/2026, 03:40:59 UTC
Views: 3
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
External Links
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.