CVE-2026-50063: CWE-125: Out-of-bounds Read in Siemens Solid Edge SE2025
A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All versions < V226.0 Update 7). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
AI Analysis
Technical Summary
This vulnerability (CWE-125) in Siemens Solid Edge SE2025 and SE2026 arises from an out-of-bounds read during the parsing of maliciously crafted PAR files. Successful exploitation could lead to arbitrary code execution with the privileges of the running process. The affected versions include all SE2025 versions before V225.0 Update 15 and all SE2026 versions before V226.0 Update 7. The CVSS 3.1 base score is 7.8, indicating high severity. No vendor advisory or patch information is currently available to confirm remediation status.
Potential Impact
An attacker who successfully exploits this vulnerability could execute arbitrary code within the context of the affected application process. This could lead to full compromise of the affected system depending on the privileges of the Solid Edge process. The vulnerability requires local access (AV:L) and user interaction (UI:R) to trigger, with no privileges required (PR:N).
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is released, avoid opening untrusted PAR files and restrict access to the affected Solid Edge versions. Monitor Siemens communications for updates on patches or mitigations.
CVE-2026-50063: CWE-125: Out-of-bounds Read in Siemens Solid Edge SE2025
Description
A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All versions < V226.0 Update 7). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
CVSS v3.1
Score 7.8high
Affected software
Weaknesses
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
This vulnerability (CWE-125) in Siemens Solid Edge SE2025 and SE2026 arises from an out-of-bounds read during the parsing of maliciously crafted PAR files. Successful exploitation could lead to arbitrary code execution with the privileges of the running process. The affected versions include all SE2025 versions before V225.0 Update 15 and all SE2026 versions before V226.0 Update 7. The CVSS 3.1 base score is 7.8, indicating high severity. No vendor advisory or patch information is currently available to confirm remediation status.
Potential Impact
An attacker who successfully exploits this vulnerability could execute arbitrary code within the context of the affected application process. This could lead to full compromise of the affected system depending on the privileges of the Solid Edge process. The vulnerability requires local access (AV:L) and user interaction (UI:R) to trigger, with no privileges required (PR:N).
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is released, avoid opening untrusted PAR files and restrict access to the affected Solid Edge versions. Monitor Siemens communications for updates on patches or mitigations.
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- siemens
- Date Reserved
- 2026-06-03T11:07:02.668Z
- Cvss Version
- 3.1
- State
- PUBLISHED
- Remediation Level
- null
Threat ID: 6a7b18a0bf8831d539b860b5
Added to database: 08/11/2026, 12:42:08 UTC
Last enriched: 08/11/2026, 13:26:09 UTC
Last updated: 08/12/2026, 03:40:59 UTC
Views: 5
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
External Links
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.
Latest Threats
Check if your credentials are on the dark web
Instant breach scanning across billions of leaked records. Free tier available.