Skip to main content
Press slash or control plus K to focus the search. Use the arrow keys to navigate results and press enter to open a threat.
Reconnecting to live updates…

CVE-2026-50063: CWE-125: Out-of-bounds Read in Siemens Solid Edge SE2025

0
High
VulnerabilityCVE-2026-50063cvecve-2026-50063cwe-125
Published: 08/11/2026 (08/11/2026, 12:20:19 UTC)
Source: CVE Database V5
Vendor/Project: Siemens
Product: Solid Edge SE2025

Description

A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All versions < V226.0 Update 7). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.

CVSS v3.1

Score 7.8high

Attack Vector
Local
Attack Complexity
Low
Privileges Required
None
User Interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Affected software

Affected versions
<225.0.15<226.0.7

AI-Powered Analysis

Machine-generated threat intelligence

AILast updated: 08/11/2026, 13:26:09 UTC

Technical Analysis

This vulnerability (CWE-125) in Siemens Solid Edge SE2025 and SE2026 arises from an out-of-bounds read during the parsing of maliciously crafted PAR files. Successful exploitation could lead to arbitrary code execution with the privileges of the running process. The affected versions include all SE2025 versions before V225.0 Update 15 and all SE2026 versions before V226.0 Update 7. The CVSS 3.1 base score is 7.8, indicating high severity. No vendor advisory or patch information is currently available to confirm remediation status.

Potential Impact

An attacker who successfully exploits this vulnerability could execute arbitrary code within the context of the affected application process. This could lead to full compromise of the affected system depending on the privileges of the Solid Edge process. The vulnerability requires local access (AV:L) and user interaction (UI:R) to trigger, with no privileges required (PR:N).

Mitigation Recommendations

Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is released, avoid opening untrusted PAR files and restrict access to the affected Solid Edge versions. Monitor Siemens communications for updates on patches or mitigations.

Pro Console: star threats, build custom feeds, automate alerts via Slack, email & webhooks.Upgrade to Pro

Technical Details

Data Version
5.2
Assigner Short Name
siemens
Date Reserved
2026-06-03T11:07:02.668Z
Cvss Version
3.1
State
PUBLISHED
Remediation Level
null

Threat ID: 6a7b18a0bf8831d539b860b5

Added to database: 08/11/2026, 12:42:08 UTC

Last enriched: 08/11/2026, 13:26:09 UTC

Last updated: 08/12/2026, 03:40:59 UTC

Views: 5

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses