CVE-2025-40740: Siemens Solid Edge SE2025 · Out-of-bounds Read
Affects Siemens Solid Edge SE2025Source CVE Database V5
Not known to be exploited · CVSS 7.8 High : upgrade to 225.0-update-5 soon.
Data as of 25 Oct 2026, 19:02 UTC
- EPSS
- 0.1% chance of exploitation in 30 days – higher than 5% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
- Patch
- Available – fixed in 225.0-update-5
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:HExploitation evidence
Disclosed: evidence found.
CVE published 8 Jul 2025
Detectable: no evidence on record.
No public nuclei template indexed
Weaponised: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 2026-10-25.
What to do
Upgrade Siemens Solid Edge SE2025 to 225.0-update-5.
Affected software
| Product | Affected | Fixed in |
|---|---|---|
| Siemens Solid Edge SE2025 | Affected
| Fixed in
|
AI-suggested
1. Immediate application of the Siemens Solid Edge SE2025 V225.0 Update 5 or later once available is critical. Monitor Siemens advisories for official patches. 2. If you cannot patch yet, implement strict controls on the handling of PAR files: restrict acceptance of PAR files from untrusted sources and enforce scanning of such files with advanced endpoint protection solutions capable of detecting malformed files. 3. Educate users on the risks of opening unsolicited or suspicious PAR files, emphasizing the importance of verifying file origins before processing. 4. Employ application whitelisting and sandboxing techniques to limit the impact of potential code execution within Solid Edge processes. 5. Monitor logs and endpoint behavior for anomalies related to Solid Edge usage, such as unexpected crashes or unusual process activity. 6. Network segmentation to isolate design workstations from critical infrastructure can limit lateral movement if exploitation occurs. 7. Maintain up-to-date backups of design data to enable recovery in case of compromise. 8. Coordinate with Siemens support for vulnerability response and guidance on interim mitigations.
Description
A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 5). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.