A vulnerability has been identified in SiPass integrated (All versions < V3.0). Affected server applications store user passwords encrypted in its database. Decryption keys are accessible to users with administrative privileges, allowing them to recover passwords.
Successful exploitation of this vulnerability allows an attacker to obtain and use valid user passwords. This can lead to unauthorized access to user accounts, data breaches, and potential system compromise.
A vulnerability has been identified in SiPass integrated (All versions < V3.0). Affected server applications contains a broken access control vulnerability. The authorization mechanism lacks sufficient server-side checks, allowing an attacker to execute a specific API request.
Successful exploitation allows an attacker to potentially manipulate data belonging to other users.
A vulnerability has been identified in SiPass integrated (All versions < V3.0). Affected server applications are vulnerable to stored Cross-Site Scripting (XSS), allowing an attacker to inject malicious code that can be executed by other users when they visit the affected page.
Successful exploitation allows an attacker to impersonate other users within the application and steal their session data. This could enable unauthorized access to accounts and potentially lead to privilege escalation.
A vulnerability has been identified in TeleControl Server Basic V3.1 (All versions >= V3.1.2.2 < V3.1.2.3). The affected application contains an information disclosure vulnerability. This could allow an unauthenticated remote attacker to obtain password hashes of users and to login to and perform authenticated operations of the database service.
CVE-2025-40755 is a high-severity SQL injection vulnerability in Siemens SINEC NMS versions prior to 4.0 SP1. It affects the getTotalAndFilterCounts endpoint and requires low-privileged authenticated access. Exploitation allows attackers to insert arbitrary SQL commands, potentially leading to privilege escalation and full compromise of the system's confidentiality, integrity, and availability. No user interaction is needed beyond authentication. Although no known exploits are currently in the wild, the vulnerability's ease of exploitation and impact make it a critical concern for organizations using SINEC NMS. European organizations relying on Siemens industrial network management solutions are particularly at risk. Mitigation requires applying vendor patches once available, restricting access to the management interface, and implementing strict input validation and monitoring. Countries with significant industrial infrastructure and Siemens deployments, such as Germany, France, Italy, and the UK, are most likely to be affected.
A vulnerability has been identified in SIMATIC Virtualization as a Service (SIVaaS) (All versions). The affected application exposes a network share without any authentication. This could allow an attacker to access or alter sensitive data without proper authorization.
A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions). The affected device exposes certain non-critical information from the device. This could allow an unauthenticated attacker to access sensitive data, potentially leading to a breach of confidentiality.
A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions). The affected device may be susceptible to resource exhaustion when subjected to high volumes of query requests.
This could allow an attacker to cause a temporary denial of service, with the system recovering once the activity stops.
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a stack-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code or to cause a denial of service condition.
A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices connected to the network allow unrestricted access to sensitive files, such as databases. This could allow an attacker to download encrypted .db file containing passwords.
A vulnerability has been identified in SINAMICS G220 V6.4 (All versions < V6.4 HF2), SINAMICS S200 V6.4 (All versions < V6.4 HF7), SINAMICS S210 V6.4 (All versions < V6.4 HF2). The affected devices allow a factory reset to be executed without the required privileges due to improper privilege management as well as manipulation of configuration data because of leaked privileges of previous sessions. This could allow an unauthorized attacker to escalate their privileges.
A vulnerability has been identified in Mendix SAML (Mendix 10.12 compatible) (All versions < V4.0.3), Mendix SAML (Mendix 10.21 compatible) (All versions < V4.1.2), Mendix SAML (Mendix 9.24 compatible) (All versions < V3.6.21). Affected versions of the module insufficiently enforce signature validation and binding checks. This could allow unauthenticated remote attackers to hijack an account in specific SSO configurations.
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions). The affected application uses a monitoring interface that is not operating in a strictly passive mode. This could allow an attacker to interact with the interface, leading to man-in-the-middle attacks.
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V3.0). The affected application uses a Content Security Policy that allows unsafe script execution methods. This could allow an attacker to execute unauthorized scripts, potentially leading to cross-site scripting attacks.
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V3.0). The affected application exposes an internal service port to be accessible from outside the system. This could allow an unauthorized attacker to access the application.
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V3.0). The affected application runs docker containers without adequate security controls to enforce isolation. This could allow an attacker to gain elevated access, potentially accessing sensitive host system resources.