Skip to main content
CVE-2024-32009VulnerabilityPublished Updated

CVE-2024-32009: Siemens Spectrum Power 4 · Incorrect Privilege Assignment

Affects Siemens Spectrum Power 4Source CVE Database V5

0

Not known to be exploited · CVSS 7.8 High.

Data as of 26 Oct 2026, 06:26 UTC

CVSS 3.1 base score
7.8High
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.1% chance of exploitation in 30 days – higher than 1% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 11 Nov 2025

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 2026-10-26.

What to do

Affected software

ProductAffectedFixed in
Siemens Spectrum Power 4Affected
  • =0
Fixed in–

AI-suggested

1. Immediately restrict local access to systems running Spectrum Power 4 to trusted and authenticated personnel only. 2. Monitor and audit local user activities for unusual privilege escalation attempts or binary executions. 3. Apply the official Siemens patch or update to Spectrum Power 4 as soon as it becomes available (V4.70 SP12 Update 2 or later). 4. In the interim, manually review and correct file system permissions on the vulnerable binary to ensure it is not executable by unauthorized users. 5. Employ endpoint detection and response (EDR) tools to detect anomalous local privilege escalation behaviors. 6. Harden local user accounts by enforcing least privilege principles and disabling unnecessary accounts. 7. Conduct regular security training for administrators and operators on the risks of local privilege escalation. 8. Implement network segmentation to limit lateral movement if a local account is compromised. 9. Maintain up-to-date backups and incident response plans tailored for industrial control systems. 10. Collaborate with Siemens support and follow advisories for any additional recommended mitigations.

Description

A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP12 Update 2). The affected application is vulnerable to a local privilege escalation due to wrongly set permissions to a binary which allows any local attacker to gain administrative privileges.

References