The Ruckus vRIoT IoT Controller firmware versions prior to 3.0.0.0 (GA) expose a command execution service on TCP port 2004 running with root privileges. Authentication to this service relies on a hardcoded Time-based One-Time Password (TOTP) secret and an embedded static token. An attacker who extracts these credentials from the appliance or a compromised device can generate valid authentication tokens and execute arbitrary OS commands with root privileges, resulting in complete system compromise.
The firmware in KAON CG3000TC and CG3000T routers contains hard-coded credentials in clear text (shared across all routers of this model) that an unauthenticated remote attacker could use to execute commands with root privileges.
This vulnerability has been fixed in firmware version: 1.00.67 for CG3000TC and 1.00.27 for CG3000T.
NVIDIA Isaac Launchable contains a vulnerability where an attacker could exploit a hard-coded credential issue. A successful exploit of this vulnerability might lead to code execution, escalation of privileges, denial of service, and data tampering.
Use of Hard-coded Credentials vulnerability in Utarit Informatics Services Inc. SoliClub allows Authentication Abuse.
This issue affects SoliClub: before 5.3.7.
Use of Hard-coded Credentials vulnerability in Utarit Information Services Inc. SoliClub allows Read Sensitive Constants Within an Executable.
This issue affects SoliClub: from 5.2.4 before 5.3.7.
A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system.
Other related CVE's are CVE-2025-14095 & CVE-2025-14097.
Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency.
Required Configuration for Exposure:
Attacker requires physical access to the analyzer.
Temporary work Around:
Only authorized people can physically access the analyzer.
Permanent solution:
Local Radiometer representatives will contact all affected customers to discuss a permanent solution.
Exploit Status:
Researchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication.
ShineLan-X contains a set of credentials for an FTP server was found within the firmware, allowing testers to establish an insecure FTP connection with the server. This may allow an attacker to replace legitimate files being deployed to devices with their own malicious versions, since the firmware signature verification is not enforced.
Growatt ShineLan-X communication dongle has an undocumented backup account with undocumented credentials which allows significant level access to the device, such as allowing any attacker to access the Setting Center. This means that this is effectively backdoor for all devices utilizing a Growatt ShineLan-X communication dongle.
Hard-coded cryptographic keys in Admin UI of EZCast Pro II before version 1.17478.177 allows attackers to bypass authorization checks and gain full access to the admin UI
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0.1). The affected device stores sensitive information in the firmware. This could allow an attacker to access and misuse this information, potentially impacting the device’s confidentiality, integrity, and availability.
An attacker can use an undocumented UART port on the PCB as a side-channel with the user hardcoded credentials obtained from CVE-2025-41692 to gain read access to parts of the filesystem of the device.
DCIM dcTrack platforms utilize default and hard-coded credentials for access. An attacker could use these credentials to administer the database, escalate privileges on the platform or execute system commands on the host.
CVE-2025-64778 is a high-severity vulnerability in Mirion Medical's EC2 Software NMIS BioDose (version 22.02 and earlier) caused by hard-coded plaintext passwords embedded in executable binaries. These credentials can be exploited by attackers with low privileges and no user interaction to gain unauthorized access to the application and its database, potentially compromising confidentiality and integrity. The vulnerability does not require network-level access but local access, limiting remote exploitation. No known exploits are currently reported in the wild. European organizations using this software in medical or radiation monitoring contexts face risks of data breaches and operational disruption. Mitigation requires removing hard-coded credentials, implementing secure credential storage, and applying vendor patches once available. Countries with significant healthcare infrastructure and usage of Mirion Medical products, such as Germany, France, and the UK, are most likely affected. Given the high CVSS score (8.4) and potential impact on sensitive medical data, immediate remediation is advised.
CVE-2025-66454 is a medium severity vulnerability in ArcadeAI's arcade-mcp HTTP server versions prior to 1.5.4. The server uses a hardcoded default worker secret key "dev" that is never validated or overridden during startup. This allows unauthenticated attackers who know the default key to forge valid JWT tokens, bypassing FastAPI authentication entirely. Exploitation grants remote access to all worker endpoints, including tool enumeration and invocation, without any credentials. The vulnerability does not require user interaction or privileges and is exploitable over the network. It is fixed in version 1.5.4.
CVE-2025-64766 is a medium-severity vulnerability in NixOS nixpkgs affecting the OnlyOffice document server module. It involves the use of a hard-coded secret to protect the file cache, allowing an attacker who knows a document's revision ID to access that document. The vulnerability affects versions from 22.11 up to but not including 25.05, and unstable versions before 25.11. Exploitation does not require authentication or user interaction but does require knowledge of a valid revision ID, which is considered difficult to obtain. The primary impact is unauthorized read access to documents that users may no longer have permission to access, potentially exposing sensitive information. The issue was fixed in NixOS versions 25.05 and unstable 25.
NVIDIA AIStore contains a vulnerability in AuthN. A successful exploit of this vulnerability might lead to escalation of privileges, information disclosure, and data tampering.
SQL Anywhere Monitor (Non-GUI) baked credentials into the code,exposing the resources or functionality to unintended users and providing attackers with the possibility of arbitrary code execution.This could cause high impact on confidentiality integrity and availability of the system.
Deck Mate 2 is distributed with static, hard-coded credentials for the root shell and web user interface, while multiple management services (SSH, HTTP, Telnet, SMB, X11) are enabled by default. If an attacker can reach these interfaces - most often through local or near-local access such as connecting to the USB or Ethernet ports beneath the table - the built-in credentials permit administrative login and full control of the system. Once authenticated, an attacker can access firmware utilities, modify controller software, and establish persistent compromise. Remote attack paths via network, cellular, or telemetry links may exist in specific configurations but generally require additional capabilities or operator error. The vendor reports that USB access has been disabled in current firmware builds.
Ghost Robotics Vision 60 v0.27.2 includes, among its physical interfaces, three RJ45 connectors and a USB Type-C port. The vulnerability is due to the lack of authentication mechanisms when establishing connections through these ports. Specifically, with regard to network connectivity, the robot's internal router automatically assigns IP addresses to any device physically connected to it. An attacker could connect a WiFi access point under their control to gain access to the robot's network without needing the credentials for the deployed network. Once inside, the attacker can monitor all its data, as the robot runs on ROS 2 without authentication by default.
The wsc server uses a hard-coded certificate to check the authenticity of SOAP messages. An unauthenticated remote attacker can extract private keys from the Software of the affected devices.