Description

Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.

AI-Powered Analysis

AILast updated: 06/20/2025, 11:48:54 UTC

Technical Analysis

CVE-2021-44693 is a medium-severity vulnerability affecting Siemens SIMATIC Drive Controller CPU 1504D TF devices running firmware versions prior to V2.9.7. The vulnerability arises from improper validation of specified quantities in input packets sent to the device's TCP port 102, which is commonly used for Siemens S7 communication protocols. Specifically, the affected devices do not correctly process specially crafted packets, allowing an attacker to trigger a denial of service (DoS) condition. This improper input validation corresponds to CWE-1284, indicating that the device fails to properly check the quantity fields in incoming packets, potentially leading to resource exhaustion or device malfunction. Exploitation does not require authentication, but it does require network access to port 102 on the device. There are no known exploits in the wild at this time, and Siemens has not provided a direct patch link, though firmware updates beyond version 2.9.7 presumably address the issue. The vulnerability impacts the availability of the SIMATIC Drive Controller, which is critical in industrial automation environments where these controllers manage drive systems and motor control. A successful DoS attack could halt industrial processes, leading to operational downtime and potential safety risks.

Potential Impact

For European organizations, particularly those in manufacturing, energy, and critical infrastructure sectors that rely on Siemens SIMATIC Drive Controllers, this vulnerability poses a significant operational risk. The DoS condition can disrupt industrial control systems (ICS), causing production stoppages, delays, and potential safety hazards if motor drives or other controlled equipment suddenly become unresponsive. Given the widespread use of Siemens automation products across Europe, especially in Germany, France, Italy, and the UK, the impact could be substantial. Disruptions in sectors such as automotive manufacturing, utilities, and transportation could have cascading effects on supply chains and service delivery. Although the vulnerability does not directly compromise confidentiality or integrity, the availability impact alone can lead to financial losses, regulatory scrutiny, and reputational damage. The lack of known exploits reduces immediate risk, but the ease of exploitation (no authentication required) means that attackers with network access could leverage this vulnerability if it becomes publicly exploited.

Mitigation Recommendations

1. Upgrade affected Siemens SIMATIC Drive Controller CPU 1504D TF devices to firmware version 2.9.7 or later as soon as possible to remediate the vulnerability. 2. Restrict network access to TCP port 102 on these devices by implementing strict firewall rules and network segmentation, ensuring that only authorized control systems and management stations can communicate with the controllers. 3. Monitor network traffic for unusual or malformed packets targeting port 102, using intrusion detection/prevention systems (IDS/IPS) with signatures or anomaly detection tailored for Siemens S7 protocols. 4. Employ network-level rate limiting or connection throttling on port 102 to mitigate potential DoS attempts. 5. Conduct regular vulnerability assessments and penetration testing focused on industrial control system components to identify and remediate similar input validation issues proactively. 6. Maintain an asset inventory of all Siemens SIMATIC devices and ensure timely application of vendor security advisories and firmware updates. 7. Train ICS network administrators on recognizing and responding to DoS conditions and suspicious network activity related to industrial protocols.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
siemens
Date Reserved
2021-12-07T00:00:00.000Z
Cisa Enriched
true

Threat ID: 682d984bc4522896dcbf81f9

Added to database: 5/21/2025, 9:09:31 AM

Last enriched: 6/20/2025, 11:48:54 AM

Last updated: 7/29/2025, 12:51:24 AM

Views: 13

Actions

PRO

Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.

Latest Threats