Skip to main content

CVE-2022-36323: CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') in Siemens RUGGEDCOM RM1224 LTE(4G) EU

Critical
VulnerabilityCVE-2022-36323cvecve-2022-36323cwe-74
Published: Wed Aug 10 2022 (08/10/2022, 11:18:33 UTC)
Source: CVE
Vendor/Project: Siemens
Product: RUGGEDCOM RM1224 LTE(4G) EU

Description

Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.

AI-Powered Analysis

AILast updated: 07/06/2025, 06:55:53 UTC

Technical Analysis

CVE-2022-36323 is a critical vulnerability identified in Siemens RUGGEDCOM RM1224 LTE(4G) EU devices, specifically affecting all versions prior to V7.1.2. The vulnerability is categorized under CWE-74, which involves improper neutralization of special elements in output used by a downstream component, commonly known as an injection flaw. In this case, the affected devices fail to properly sanitize an input field, which can be exploited by an authenticated remote attacker possessing administrative privileges. This flaw allows the attacker to inject arbitrary code or spawn a system root shell, effectively gaining root-level control over the device. The vulnerability has a CVSS 3.1 base score of 9.1, indicating a critical severity level. The attack vector is network-based (AV:N), requiring high privileges (PR:H) but no user interaction (UI:N). The scope is changed (S:C), meaning the vulnerability can affect resources beyond the initially vulnerable component. The impact on confidentiality, integrity, and availability is high (C:H/I:H/A:H), and the exploitability is partially functional (E:P) with official remediation options (RL:O) and confirmed fix (RC:C). Although no known exploits are currently reported in the wild, the potential for severe impact is significant due to the ability to execute arbitrary code with root privileges remotely. Siemens RUGGEDCOM RM1224 LTE(4G) devices are ruggedized industrial network devices commonly used in critical infrastructure sectors such as energy, transportation, and utilities, where LTE connectivity is required for remote communications. The vulnerability poses a substantial risk to operational technology (OT) environments that rely on these devices for secure and reliable network communications.

Potential Impact

For European organizations, especially those operating in critical infrastructure sectors like energy grids, transportation networks, and industrial automation, this vulnerability presents a severe risk. Exploitation could lead to unauthorized root access, enabling attackers to manipulate device configurations, disrupt communications, or pivot deeper into OT networks. This could result in operational downtime, data breaches, or sabotage of essential services. Given the critical role of Siemens RUGGEDCOM devices in secure LTE communications for industrial environments, a successful attack could compromise the integrity and availability of critical systems, potentially causing cascading failures. The high confidentiality impact also raises concerns about sensitive operational data exposure. European organizations with remote or distributed infrastructure relying on these devices are particularly vulnerable due to the network-exposed nature of the flaw and the possibility of remote exploitation by insiders or compromised administrators.

Mitigation Recommendations

1. Immediate upgrade: Organizations should prioritize upgrading all affected Siemens RUGGEDCOM RM1224 LTE(4G) devices to version 7.1.2 or later, where the vulnerability has been patched. 2. Access control hardening: Restrict administrative access to these devices using network segmentation, VPNs, or jump hosts to limit exposure to trusted personnel only. 3. Multi-factor authentication (MFA): Implement MFA for administrative access to reduce the risk of credential compromise leading to exploitation. 4. Input validation: Although the vendor patch addresses the root cause, organizations should monitor device logs for suspicious input patterns indicative of injection attempts. 5. Network monitoring: Deploy intrusion detection/prevention systems (IDS/IPS) tuned to detect anomalous commands or shell spawning attempts on these devices. 6. Incident response readiness: Prepare and test incident response plans specifically for OT environments to quickly isolate and remediate affected devices if exploitation is suspected. 7. Vendor coordination: Maintain close communication with Siemens for updates on patches, advisories, and best practices related to this vulnerability. 8. Configuration audits: Regularly audit device configurations to ensure no unauthorized changes have been made and that security best practices are enforced.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
siemens
Date Reserved
2022-07-20T00:00:00.000Z
Cisa Enriched
true
Cvss Version
3.1
State
PUBLISHED

Threat ID: 682cd8894d7c5ea9f4b36f81

Added to database: 5/20/2025, 7:31:21 PM

Last enriched: 7/6/2025, 6:55:53 AM

Last updated: 8/14/2025, 8:06:19 PM