CVE-2022-45092VulnerabilityPublished Updated

CVE-2022-45092: Siemens SINEC INS · Path Traversal

Affects Siemens SINEC INSSource CVE Database V5

0

Not known to be exploited · 31% EPSS · CVSS 9.9 Critical.

Data as of 26 Oct 2026, 06:26 UTC

CVSS 3.1 base score
9.9Critical
How severe the flaw is on the 0–10 CVSS scale.
EPSS
31.4% chance of exploitation in 30 days – higher than 98% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 10 Jan 2023

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 2026-10-26.

What to do

AI-suggested

1. Immediate upgrade to Siemens SINEC INS version V1.0 SP2 Update 1 or later, where the vulnerability is patched. 2. Restrict access to the web-based management interface (port 443) using network segmentation, firewall rules, and VPNs to limit exposure to trusted administrators only. 3. Implement strong authentication mechanisms and monitor for unusual login activity to detect potential misuse of credentials. 4. Employ file integrity monitoring on affected devices to detect unauthorized file changes. 5. Regularly audit and review user accounts with access to the management interface to ensure least privilege principles. 6. If patching is not immediately possible, consider disabling the web management interface or restricting it to isolated management networks. 7. Conduct penetration testing and vulnerability scanning focused on path traversal and file manipulation vulnerabilities in industrial network devices. 8. Maintain up-to-date incident response plans tailored to industrial control system environments to quickly contain and remediate any exploitation attempts.

Description

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product, could potentially read and write arbitrary files from and to the device's file system. An attacker might leverage this to trigger remote code execution on the affected component.