CVE-2023-2264: CWE-20 Improper Input Validation in Schweitzer Engineering Laboratories SEL-411L
An improper input validation vulnerability in the Schweitzer Engineering Laboratories SEL-411L could allow a malicious actor to manipulate authorized users to click on a link that could allow undesired behavior. See product Instruction Manual Appendix A dated 20230830 for more details.
AI Analysis
Technical Summary
CVE-2023-2264 is a medium-severity vulnerability identified in the Schweitzer Engineering Laboratories (SEL) SEL-411L device, which is a protective relay used in electrical power systems for monitoring and control. The vulnerability stems from improper input validation (CWE-20), which could be exploited by a malicious actor to manipulate authorized users into clicking a crafted link that triggers undesired behavior in the device. Specifically, the flaw allows an attacker with high privileges (PR:H) and requiring user interaction (UI:R) to exploit the vulnerability remotely (AV:L - local network access). The vulnerability affects multiple firmware versions ranging from R118-V0 through R129-V0. The improper input validation could lead to limited impacts on confidentiality, integrity, and availability, as indicated by the CVSS vector (C:L/I:L/A:L). No known exploits are currently reported in the wild, and no patches have been linked yet. The vulnerability is documented in the product's Instruction Manual Appendix A dated 20230830, suggesting that detailed technical guidance is available from the vendor. The SEL-411L is critical infrastructure equipment, and improper input validation could potentially allow attackers to cause operational disruptions or unauthorized control actions if exploited successfully, especially in environments where users might be tricked into interacting with malicious links.
Potential Impact
For European organizations, particularly those operating critical electrical infrastructure, this vulnerability poses a risk of operational disruption and potential safety hazards. The SEL-411L is widely used in power generation, transmission, and distribution networks, which are vital for national infrastructure. Exploitation could lead to unauthorized commands or data manipulation, impacting the reliability and stability of power systems. Although the CVSS score is medium, the critical nature of the affected systems elevates the potential impact. European utilities and grid operators could face service interruptions, increased risk of cascading failures, or regulatory non-compliance if the vulnerability is exploited. Additionally, the requirement for user interaction means that social engineering could be a vector, increasing the risk in environments where operational staff might be targeted with phishing or spear-phishing campaigns. The impact on confidentiality is limited, but integrity and availability impacts, even if low to medium, can have significant consequences in critical infrastructure contexts.
Mitigation Recommendations
1. Immediately review and follow any guidance provided in the SEL-411L Instruction Manual Appendix A (20230830) for mitigating this vulnerability. 2. Restrict access to the SEL-411L management interfaces to trusted personnel only and enforce strict network segmentation to limit exposure to local network threats. 3. Implement robust user training and awareness programs focused on recognizing and avoiding phishing and social engineering attempts, as exploitation requires user interaction. 4. Monitor network traffic and device logs for unusual activity that could indicate attempts to exploit this vulnerability. 5. Apply any firmware updates or patches released by Schweitzer Engineering Laboratories as soon as they become available. 6. Consider deploying additional security controls such as multi-factor authentication and strict privilege management to reduce the risk of unauthorized access. 7. Conduct regular security assessments and penetration testing focused on the SEL-411L and related infrastructure to identify and remediate potential weaknesses.
Affected Countries
Germany, France, United Kingdom, Italy, Spain, Poland, Netherlands, Belgium, Sweden, Norway
CVE-2023-2264: CWE-20 Improper Input Validation in Schweitzer Engineering Laboratories SEL-411L
Description
An improper input validation vulnerability in the Schweitzer Engineering Laboratories SEL-411L could allow a malicious actor to manipulate authorized users to click on a link that could allow undesired behavior. See product Instruction Manual Appendix A dated 20230830 for more details.
AI-Powered Analysis
Technical Analysis
CVE-2023-2264 is a medium-severity vulnerability identified in the Schweitzer Engineering Laboratories (SEL) SEL-411L device, which is a protective relay used in electrical power systems for monitoring and control. The vulnerability stems from improper input validation (CWE-20), which could be exploited by a malicious actor to manipulate authorized users into clicking a crafted link that triggers undesired behavior in the device. Specifically, the flaw allows an attacker with high privileges (PR:H) and requiring user interaction (UI:R) to exploit the vulnerability remotely (AV:L - local network access). The vulnerability affects multiple firmware versions ranging from R118-V0 through R129-V0. The improper input validation could lead to limited impacts on confidentiality, integrity, and availability, as indicated by the CVSS vector (C:L/I:L/A:L). No known exploits are currently reported in the wild, and no patches have been linked yet. The vulnerability is documented in the product's Instruction Manual Appendix A dated 20230830, suggesting that detailed technical guidance is available from the vendor. The SEL-411L is critical infrastructure equipment, and improper input validation could potentially allow attackers to cause operational disruptions or unauthorized control actions if exploited successfully, especially in environments where users might be tricked into interacting with malicious links.
Potential Impact
For European organizations, particularly those operating critical electrical infrastructure, this vulnerability poses a risk of operational disruption and potential safety hazards. The SEL-411L is widely used in power generation, transmission, and distribution networks, which are vital for national infrastructure. Exploitation could lead to unauthorized commands or data manipulation, impacting the reliability and stability of power systems. Although the CVSS score is medium, the critical nature of the affected systems elevates the potential impact. European utilities and grid operators could face service interruptions, increased risk of cascading failures, or regulatory non-compliance if the vulnerability is exploited. Additionally, the requirement for user interaction means that social engineering could be a vector, increasing the risk in environments where operational staff might be targeted with phishing or spear-phishing campaigns. The impact on confidentiality is limited, but integrity and availability impacts, even if low to medium, can have significant consequences in critical infrastructure contexts.
Mitigation Recommendations
1. Immediately review and follow any guidance provided in the SEL-411L Instruction Manual Appendix A (20230830) for mitigating this vulnerability. 2. Restrict access to the SEL-411L management interfaces to trusted personnel only and enforce strict network segmentation to limit exposure to local network threats. 3. Implement robust user training and awareness programs focused on recognizing and avoiding phishing and social engineering attempts, as exploitation requires user interaction. 4. Monitor network traffic and device logs for unusual activity that could indicate attempts to exploit this vulnerability. 5. Apply any firmware updates or patches released by Schweitzer Engineering Laboratories as soon as they become available. 6. Consider deploying additional security controls such as multi-factor authentication and strict privilege management to reduce the risk of unauthorized access. 7. Conduct regular security assessments and penetration testing focused on the SEL-411L and related infrastructure to identify and remediate potential weaknesses.
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- SEL
- Date Reserved
- 2023-04-24T23:18:40.218Z
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 683ee1eb182aa0cae2739666
Added to database: 6/3/2025, 11:52:11 AM
Last enriched: 7/3/2025, 6:25:29 PM
Last updated: 8/12/2025, 2:19:32 AM
Views: 16
Related Threats
CVE-2025-8885: CWE-770 Allocation of Resources Without Limits or Throttling in Legion of the Bouncy Castle Inc. Bouncy Castle for Java
MediumCVE-2025-26398: CWE-798 Use of Hard-coded Credentials in SolarWinds Database Performance Analyzer
MediumCVE-2025-41686: CWE-306 Missing Authentication for Critical Function in Phoenix Contact DaUM
HighCVE-2025-8874: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in litonice13 Master Addons – Elementor Addons with White Label, Free Widgets, Hover Effects, Conditions, & Animations
MediumCVE-2025-8767: CWE-1236 Improper Neutralization of Formula Elements in a CSV File in anwppro AnWP Football Leagues
MediumActions
Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.
External Links
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.