CVE-2023-49127: CWE-125: Out-of-bounds Read in Siemens Solid Edge SE2023
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
AI Analysis
Technical Summary
CVE-2023-49127 is a high-severity vulnerability identified in Siemens Solid Edge SE2023, specifically affecting all versions prior to V223.0 Update 10. The vulnerability is classified as CWE-125, an out-of-bounds read, which occurs when the application parses specially crafted PAR files. This parsing flaw allows the software to read memory beyond the allocated boundary of a data structure. Such out-of-bounds reads can lead to undefined behavior, including the potential for arbitrary code execution within the context of the current process. The vulnerability requires local access (AV:L) but does not require privileges (PR:N), though it does require user interaction (UI:R) to trigger. The CVSS v3.1 base score is 7.8, reflecting high impact on confidentiality, integrity, and availability (all rated high). The exploitability is rated as low complexity (AC:L), and the scope remains unchanged (S:U). No known exploits are currently reported in the wild, and Siemens has not yet published a patch, though the vulnerability is publicly disclosed and tracked by CISA. The vulnerability arises from improper bounds checking when handling PAR files, which are likely project or parameter files used by Solid Edge for CAD data. Successful exploitation could allow an attacker to execute arbitrary code, potentially leading to system compromise or data theft within the CAD environment.
Potential Impact
For European organizations, especially those in manufacturing, engineering, and design sectors that rely on Siemens Solid Edge SE2023 for CAD operations, this vulnerability poses a significant risk. Exploitation could lead to unauthorized code execution, resulting in theft or manipulation of sensitive intellectual property, disruption of design workflows, and potential sabotage of product designs. Given the critical role of CAD software in product development, such an attack could delay production cycles and cause financial losses. Additionally, compromised systems could serve as entry points for lateral movement within corporate networks, increasing the risk of broader cyber incidents. The requirement for local access and user interaction somewhat limits remote exploitation, but targeted phishing or insider threat scenarios remain plausible. The high impact on confidentiality, integrity, and availability underscores the potential for severe operational and reputational damage to European firms using affected versions of Solid Edge.
Mitigation Recommendations
1. Immediate upgrade to Siemens Solid Edge SE2023 version V223.0 Update 10 or later once available, as this will contain the official patch addressing the vulnerability. 2. Until patching is possible, restrict access to systems running Solid Edge to trusted users only and enforce strict endpoint security controls to prevent execution of untrusted PAR files. 3. Implement application whitelisting and file integrity monitoring specifically for PAR files to detect and block suspicious or malformed files. 4. Educate users about the risks of opening unexpected or unsolicited PAR files, emphasizing caution with email attachments or downloads. 5. Employ network segmentation to isolate engineering workstations from broader corporate networks to limit lateral movement if compromise occurs. 6. Monitor logs and endpoint detection systems for unusual Solid Edge process behavior or crashes that could indicate exploitation attempts. 7. Coordinate with Siemens support for any interim mitigation guidance and subscribe to Siemens security advisories for timely updates. These steps go beyond generic patching advice by focusing on access control, user awareness, and monitoring tailored to the CAD environment and file types involved.
Affected Countries
Germany, France, Italy, United Kingdom, Netherlands, Sweden, Belgium, Spain, Poland, Czech Republic
CVE-2023-49127: CWE-125: Out-of-bounds Read in Siemens Solid Edge SE2023
Description
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
AI-Powered Analysis
Technical Analysis
CVE-2023-49127 is a high-severity vulnerability identified in Siemens Solid Edge SE2023, specifically affecting all versions prior to V223.0 Update 10. The vulnerability is classified as CWE-125, an out-of-bounds read, which occurs when the application parses specially crafted PAR files. This parsing flaw allows the software to read memory beyond the allocated boundary of a data structure. Such out-of-bounds reads can lead to undefined behavior, including the potential for arbitrary code execution within the context of the current process. The vulnerability requires local access (AV:L) but does not require privileges (PR:N), though it does require user interaction (UI:R) to trigger. The CVSS v3.1 base score is 7.8, reflecting high impact on confidentiality, integrity, and availability (all rated high). The exploitability is rated as low complexity (AC:L), and the scope remains unchanged (S:U). No known exploits are currently reported in the wild, and Siemens has not yet published a patch, though the vulnerability is publicly disclosed and tracked by CISA. The vulnerability arises from improper bounds checking when handling PAR files, which are likely project or parameter files used by Solid Edge for CAD data. Successful exploitation could allow an attacker to execute arbitrary code, potentially leading to system compromise or data theft within the CAD environment.
Potential Impact
For European organizations, especially those in manufacturing, engineering, and design sectors that rely on Siemens Solid Edge SE2023 for CAD operations, this vulnerability poses a significant risk. Exploitation could lead to unauthorized code execution, resulting in theft or manipulation of sensitive intellectual property, disruption of design workflows, and potential sabotage of product designs. Given the critical role of CAD software in product development, such an attack could delay production cycles and cause financial losses. Additionally, compromised systems could serve as entry points for lateral movement within corporate networks, increasing the risk of broader cyber incidents. The requirement for local access and user interaction somewhat limits remote exploitation, but targeted phishing or insider threat scenarios remain plausible. The high impact on confidentiality, integrity, and availability underscores the potential for severe operational and reputational damage to European firms using affected versions of Solid Edge.
Mitigation Recommendations
1. Immediate upgrade to Siemens Solid Edge SE2023 version V223.0 Update 10 or later once available, as this will contain the official patch addressing the vulnerability. 2. Until patching is possible, restrict access to systems running Solid Edge to trusted users only and enforce strict endpoint security controls to prevent execution of untrusted PAR files. 3. Implement application whitelisting and file integrity monitoring specifically for PAR files to detect and block suspicious or malformed files. 4. Educate users about the risks of opening unexpected or unsolicited PAR files, emphasizing caution with email attachments or downloads. 5. Employ network segmentation to isolate engineering workstations from broader corporate networks to limit lateral movement if compromise occurs. 6. Monitor logs and endpoint detection systems for unusual Solid Edge process behavior or crashes that could indicate exploitation attempts. 7. Coordinate with Siemens support for any interim mitigation guidance and subscribe to Siemens security advisories for timely updates. These steps go beyond generic patching advice by focusing on access control, user awareness, and monitoring tailored to the CAD environment and file types involved.
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- siemens
- Date Reserved
- 2023-11-22T14:50:33.103Z
- Cisa Enriched
- true
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 682d983ac4522896dcbed122
Added to database: 5/21/2025, 9:09:14 AM
Last enriched: 6/25/2025, 4:40:48 PM
Last updated: 7/31/2025, 1:12:00 PM
Views: 11
Related Threats
Researcher to release exploit for full auth bypass on FortiWeb
HighCVE-2025-9091: Hard-coded Credentials in Tenda AC20
LowCVE-2025-9090: Command Injection in Tenda AC20
MediumCVE-2025-9092: CWE-400 Uncontrolled Resource Consumption in Legion of the Bouncy Castle Inc. Bouncy Castle for Java - BC-FJA 2.1.0
LowCVE-2025-9089: Stack-based Buffer Overflow in Tenda AC20
HighActions
Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.
External Links
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.