CVE-2023-53969: Missing Authentication for Critical Function in DB Elettronica Telecomunicazioni SpA Screen SFT DAB 600/C
Screen SFT DAB 600/C firmware 1.9.3 contains a session management vulnerability that allows attackers to bypass authentication controls by exploiting IP address session binding. Attackers can reuse the same IP address and issue unauthorized requests to the userManager API to change user passwords without proper authentication.
AI Analysis
Technical Summary
CVE-2023-53969 identifies a critical vulnerability in the Screen SFT DAB 600/C device firmware version 1.9.3 produced by DB Elettronica Telecomunicazioni SpA. The vulnerability arises from improper session management, specifically the reliance on IP address session binding to enforce authentication. Attackers can exploit this by reusing the same IP address to bypass authentication controls entirely, allowing them to issue unauthorized requests to the userManager API. This API controls user management functions, including password changes. Because no authentication or user interaction is required, the attacker can remotely change user passwords, effectively gaining administrative control over the device. The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N) indicates that the attack is network-based, requires no privileges or user interaction, and results in high confidentiality, integrity, and availability impact. The lack of patch links suggests no official firmware update is currently available, increasing the urgency for mitigation. The device is typically used in telecommunications infrastructure, making it a high-value target for attackers aiming to disrupt or control telecom services. The vulnerability's exploitation could lead to unauthorized device configuration changes, service disruptions, and potential lateral movement within affected networks.
Potential Impact
For European organizations, especially telecom operators and infrastructure providers using the Screen SFT DAB 600/C device, this vulnerability poses a severe risk. Unauthorized password changes can lead to full administrative takeover of the device, allowing attackers to alter configurations, disrupt services, or use the device as a foothold for further network intrusion. This could impact the confidentiality of sensitive telecom data, the integrity of network operations, and the availability of critical communication services. Given the device's role in telecom infrastructure, exploitation could affect large user bases and critical communications, including emergency services. The lack of authentication requirements and ease of exploitation over the network increase the likelihood of attacks. Additionally, compromised devices could be leveraged for espionage, sabotage, or as part of botnets, amplifying the threat to European digital infrastructure and national security interests.
Mitigation Recommendations
Immediate mitigation should focus on network-level controls such as restricting access to the Screen SFT DAB 600/C management interfaces to trusted IP addresses and network segments. Implement strict firewall rules and network segmentation to isolate these devices from general network access. Monitor network traffic for unusual or repeated API calls to the userManager endpoint, which may indicate exploitation attempts. If possible, disable remote management features until a secure firmware update is available. Engage with DB Elettronica Telecomunicazioni SpA for official patches or firmware updates addressing this vulnerability. Employ multi-factor authentication (MFA) on management interfaces if supported, to add an additional layer of security. Conduct regular audits of device configurations and user accounts to detect unauthorized changes promptly. Finally, incorporate this vulnerability into incident response plans to ensure rapid detection and remediation if exploitation occurs.
Affected Countries
Italy, Germany, France, Spain, United Kingdom, Netherlands
CVE-2023-53969: Missing Authentication for Critical Function in DB Elettronica Telecomunicazioni SpA Screen SFT DAB 600/C
Description
Screen SFT DAB 600/C firmware 1.9.3 contains a session management vulnerability that allows attackers to bypass authentication controls by exploiting IP address session binding. Attackers can reuse the same IP address and issue unauthorized requests to the userManager API to change user passwords without proper authentication.
AI-Powered Analysis
Technical Analysis
CVE-2023-53969 identifies a critical vulnerability in the Screen SFT DAB 600/C device firmware version 1.9.3 produced by DB Elettronica Telecomunicazioni SpA. The vulnerability arises from improper session management, specifically the reliance on IP address session binding to enforce authentication. Attackers can exploit this by reusing the same IP address to bypass authentication controls entirely, allowing them to issue unauthorized requests to the userManager API. This API controls user management functions, including password changes. Because no authentication or user interaction is required, the attacker can remotely change user passwords, effectively gaining administrative control over the device. The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N) indicates that the attack is network-based, requires no privileges or user interaction, and results in high confidentiality, integrity, and availability impact. The lack of patch links suggests no official firmware update is currently available, increasing the urgency for mitigation. The device is typically used in telecommunications infrastructure, making it a high-value target for attackers aiming to disrupt or control telecom services. The vulnerability's exploitation could lead to unauthorized device configuration changes, service disruptions, and potential lateral movement within affected networks.
Potential Impact
For European organizations, especially telecom operators and infrastructure providers using the Screen SFT DAB 600/C device, this vulnerability poses a severe risk. Unauthorized password changes can lead to full administrative takeover of the device, allowing attackers to alter configurations, disrupt services, or use the device as a foothold for further network intrusion. This could impact the confidentiality of sensitive telecom data, the integrity of network operations, and the availability of critical communication services. Given the device's role in telecom infrastructure, exploitation could affect large user bases and critical communications, including emergency services. The lack of authentication requirements and ease of exploitation over the network increase the likelihood of attacks. Additionally, compromised devices could be leveraged for espionage, sabotage, or as part of botnets, amplifying the threat to European digital infrastructure and national security interests.
Mitigation Recommendations
Immediate mitigation should focus on network-level controls such as restricting access to the Screen SFT DAB 600/C management interfaces to trusted IP addresses and network segments. Implement strict firewall rules and network segmentation to isolate these devices from general network access. Monitor network traffic for unusual or repeated API calls to the userManager endpoint, which may indicate exploitation attempts. If possible, disable remote management features until a secure firmware update is available. Engage with DB Elettronica Telecomunicazioni SpA for official patches or firmware updates addressing this vulnerability. Employ multi-factor authentication (MFA) on management interfaces if supported, to add an additional layer of security. Conduct regular audits of device configurations and user accounts to detect unauthorized changes promptly. Finally, incorporate this vulnerability into incident response plans to ensure rapid detection and remediation if exploitation occurs.
Affected Countries
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- VulnCheck
- Date Reserved
- 2025-12-19T14:03:57.726Z
- Cvss Version
- 4.0
- State
- PUBLISHED
Threat ID: 6949bf37edc45005c15e3458
Added to database: 12/22/2025, 9:59:19 PM
Last enriched: 12/22/2025, 10:15:49 PM
Last updated: 12/26/2025, 7:04:22 PM
Views: 14
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
Need more coverage?
Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.