Skip to main content

CVE-2024-21620: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in Juniper Networks Junos OS

High
VulnerabilityCVE-2024-21620cvecve-2024-21620cwe-79
Published: Thu Jan 25 2024 (01/25/2024, 22:50:18 UTC)
Source: CVE Database V5
Vendor/Project: Juniper Networks
Product: Junos OS

Description

An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in J-Web of Juniper Networks Junos OS on SRX Series and EX Series allows an attacker to construct a URL that when visited by another user enables the attacker to execute commands with the target's permissions, including an administrator. A specific invocation of the emit_debug_note method in webauth_operation.php will echo back the data it receives. This issue affects Juniper Networks Junos OS on SRX Series and EX Series: * All versions earlier than 20.4R3-S10; * 21.2 versions earlier than 21.2R3-S8; * 21.4 versions earlier than 21.4R3-S6; * 22.1 versions earlier than 22.1R3-S5; * 22.2 versions earlier than 22.2R3-S3; * 22.3 versions earlier than 22.3R3-S2; * 22.4 versions earlier than 22.4R3-S1; * 23.2 versions earlier than 23.2R2; * 23.4 versions earlier than 23.4R2.

AI-Powered Analysis

AILast updated: 07/07/2025, 23:55:23 UTC

Technical Analysis

CVE-2024-21620 is a high-severity Cross-site Scripting (XSS) vulnerability affecting the J-Web management interface of Juniper Networks Junos OS running on SRX Series and EX Series devices. The vulnerability arises due to improper neutralization of input during web page generation, specifically in the emit_debug_note method within the webauth_operation.php script. This method echoes back user-supplied data without proper sanitization, allowing an attacker to craft a malicious URL that, when visited by an authenticated user (including administrators), can execute arbitrary commands with the victim's privileges. The vulnerability affects multiple versions of Junos OS, including all versions earlier than 20.4R3-S10, and various 21.x through 23.x releases prior to their respective patch versions. The CVSS v3.1 base score is 8.8, indicating a high impact with network attack vector, low attack complexity, no privileges required, but requiring user interaction. The vulnerability impacts confidentiality, integrity, and availability, as an attacker can execute commands remotely in the context of the victim's session, potentially leading to full system compromise. No known exploits in the wild have been reported yet, but the vulnerability's nature and affected product's widespread use in enterprise and service provider networks make it a critical concern. Junos OS is widely deployed in firewall, routing, and switching infrastructure, making this vulnerability a significant risk for network security management interfaces.

Potential Impact

For European organizations, this vulnerability poses a substantial risk to network infrastructure security. Juniper SRX and EX Series devices are commonly used in enterprise and service provider environments across Europe for firewalling, routing, and switching. Exploitation could allow attackers to bypass administrative controls by executing arbitrary commands with administrator privileges via the web management interface. This can lead to unauthorized access, data exfiltration, network disruption, and potential lateral movement within corporate networks. Given the vulnerability requires user interaction (visiting a malicious URL), targeted phishing or social engineering campaigns could be used against network administrators. The compromise of network management devices can severely impact confidentiality and integrity of network traffic and configurations, as well as availability if devices are manipulated or disabled. The high CVSS score reflects the criticality of this threat. European organizations in sectors such as finance, telecommunications, government, and critical infrastructure, which rely heavily on Juniper devices, are particularly at risk. The vulnerability could also be leveraged in broader cyber espionage or sabotage campaigns given the strategic importance of network infrastructure.

Mitigation Recommendations

1. Immediate patching: Organizations should prioritize upgrading Junos OS on affected SRX and EX Series devices to the fixed versions listed (e.g., 20.4R3-S10 or later). Applying vendor-provided patches is the most effective mitigation. 2. Access restrictions: Limit access to the J-Web management interface to trusted networks and IP addresses only, using firewall rules and network segmentation to reduce exposure. 3. Multi-factor authentication (MFA): Enforce MFA for administrative access to the management interface to reduce risk from compromised credentials. 4. User awareness: Train network administrators to recognize and avoid phishing attempts that could deliver malicious URLs exploiting this vulnerability. 5. Monitoring and logging: Enable detailed logging of management interface access and monitor for suspicious URL requests or unusual administrative activity. 6. Disable J-Web if not required: If feasible, disable the web management interface and use CLI or other secure management methods to reduce attack surface. 7. Incident response readiness: Prepare to respond to potential exploitation attempts by having forensic and recovery procedures in place for Juniper devices. These steps go beyond generic advice by focusing on reducing attack surface, enforcing strong access controls, and preparing for incident detection and response specific to Junos OS management interfaces.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
juniper
Date Reserved
2023-12-27T19:38:25.710Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 68387d4f182aa0cae28316f2

Added to database: 5/29/2025, 3:29:19 PM

Last enriched: 7/7/2025, 11:55:23 PM

Last updated: 8/15/2025, 10:37:47 PM

Views: 16

Actions

PRO

Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.