Skip to main content
Press slash or control plus K to focus the search. Use the arrow keys to navigate results and press enter to open a threat.
Reconnecting to live updates…

CVE-2024-39219: n/a

0
High
VulnerabilityCVE-2024-39219cvecve-2024-39219
Published: Wed Dec 04 2024 (12/04/2024, 00:00:00 UTC)
Source: CVE Database V5

Description

CVE-2024-39219 is a high-severity vulnerability affecting Aginode GigaSwitch devices running versions prior to 7. 06G. Authenticated attackers with Administrator privileges can exploit this flaw to downgrade the device firmware to an earlier version, thereby reintroducing previously patched vulnerabilities. This downgrade attack compromises the device's confidentiality, integrity, and availability, as older firmware may contain critical security flaws. Exploitation requires no user interaction but does require administrative access, making insider threats or compromised admin accounts a key risk factor. No known exploits are currently reported in the wild. Organizations using affected Aginode GigaSwitch devices should prioritize upgrading to version 7. 06G or later to mitigate this risk. The vulnerability poses significant risk to network infrastructure relying on these switches, especially in sectors where Aginode devices are prevalent. Countries with substantial deployments of Aginode networking equipment and critical infrastructure are most at risk.

AI-Powered Analysis

AILast updated: 02/26/2026, 05:51:38 UTC

Technical Analysis

CVE-2024-39219 is a firmware downgrade vulnerability in Aginode GigaSwitch V5 devices prior to version 7.06G. The vulnerability allows an attacker with authenticated Administrator privileges to upload and install an older firmware version on the device. This rollback attack effectively bypasses security improvements and patches applied in newer firmware versions, exposing the device to previously resolved vulnerabilities. The attack vector is network-based (AV:N), requires low attack complexity (AC:L), and privileges at the Administrator level (PR:L), but does not require user interaction (UI:N). The vulnerability impacts confidentiality, integrity, and availability (C:H/I:H/A:H) of the device and potentially the broader network it supports. The lack of patch links suggests that remediation involves upgrading to version 7.06G or later, which presumably fixes the downgrade flaw. No known exploits have been reported in the wild, but the high CVSS score of 8.8 indicates a critical risk if exploited. This vulnerability is particularly dangerous because it enables attackers to revert security controls by installing vulnerable firmware, potentially facilitating further compromise or persistent access.

Potential Impact

The impact of CVE-2024-39219 is significant for organizations using Aginode GigaSwitch devices in their network infrastructure. Successful exploitation can lead to the reintroduction of critical vulnerabilities, enabling attackers to compromise device confidentiality, manipulate network traffic, disrupt network availability, or gain persistent unauthorized access. This can result in network outages, data breaches, and lateral movement within enterprise environments. Since the vulnerability requires Administrator privileges, the risk is heightened in scenarios where admin credentials are stolen, shared, or weakly protected. The ability to downgrade firmware undermines trust in device integrity and complicates incident response and forensic investigations. Organizations in sectors such as telecommunications, government, finance, and critical infrastructure that rely on Aginode switches may face operational disruptions and increased exposure to advanced persistent threats.

Mitigation Recommendations

To mitigate CVE-2024-39219, organizations should immediately upgrade all affected Aginode GigaSwitch devices to firmware version 7.06G or later, where the vulnerability is addressed. Implement strict access controls and multi-factor authentication for all administrator accounts to reduce the risk of credential compromise. Monitor firmware upgrade activities and maintain logs to detect unauthorized downgrade attempts. Employ network segmentation to limit the exposure of management interfaces to trusted personnel and systems only. Regularly audit device configurations and firmware versions to ensure compliance with security policies. Additionally, consider implementing anomaly detection systems that can alert on unusual firmware changes or administrative actions. If upgrading is not immediately possible, restrict administrative access to the devices and increase monitoring for suspicious activities until patches can be applied.

Need more detailed analysis?Upgrade to Pro Console

Technical Details

Data Version
5.1
Assigner Short Name
mitre
Date Reserved
2024-06-21T00:00:00.000Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 699f6c85b7ef31ef0b565d43

Added to database: 2/25/2026, 9:41:25 PM

Last enriched: 2/26/2026, 5:51:38 AM

Last updated: 2/26/2026, 10:32:16 AM

Views: 2

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats