Skip to main content

CVE-2024-39876: CWE-770: Allocation of Resources Without Limits or Throttling in Siemens SINEMA Remote Connect Server

Medium
VulnerabilityCVE-2024-39876cvecve-2024-39876cwe-770
Published: Tue Jul 09 2024 (07/09/2024, 12:05:34 UTC)
Source: CVE
Vendor/Project: Siemens
Product: SINEMA Remote Connect Server

Description

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected applications do not properly handle log rotation. This could allow an unauthenticated remote attacker to cause a denial of service condition through resource exhaustion on the device.

AI-Powered Analysis

AILast updated: 06/25/2025, 15:32:09 UTC

Technical Analysis

CVE-2024-39876 is a medium-severity vulnerability identified in Siemens SINEMA Remote Connect Server versions prior to V3.2 SP1. The root cause is improper handling of log rotation, which leads to uncontrolled allocation of system resources. Specifically, the affected software does not implement limits or throttling mechanisms when managing log files, resulting in resource exhaustion. An unauthenticated remote attacker can exploit this flaw to trigger a denial of service (DoS) condition by overwhelming the device's resources, such as CPU, memory, or disk space, through continuous or malformed requests that cause excessive logging activity. This vulnerability is classified under CWE-770, which pertains to allocation of resources without limits or throttling. The CVSS v3.1 base score is 4.0 (medium), with the vector indicating local attack vector (AV:L), low attack complexity (AC:L), no privileges required (PR:N), no user interaction (UI:N), unchanged scope (S:U), no impact on confidentiality or integrity (C:N/I:N), but causing availability impact (A:L). The exploitability is partially functional (E:P), with official remediation (RL:O) and confirmed fix (RC:C). There are no known exploits in the wild at the time of publication. The vulnerability affects all versions before V3.2 SP1, and Siemens has not yet published a patch link. The issue is significant because SINEMA Remote Connect Server is widely used in industrial and critical infrastructure environments to enable secure remote access to automation systems, making availability crucial for operational continuity.

Potential Impact

For European organizations, especially those operating in industrial automation, manufacturing, energy, and critical infrastructure sectors, this vulnerability poses a risk of service disruption. An attacker exploiting this flaw could cause denial of service on SINEMA Remote Connect Server devices, potentially interrupting remote management and monitoring capabilities. This disruption could delay incident response, maintenance, or operational adjustments, leading to operational downtime and financial losses. Although the vulnerability does not compromise confidentiality or integrity, the availability impact can have cascading effects on industrial processes and safety systems reliant on continuous remote connectivity. Given the increasing reliance on remote access solutions in European industrial environments, the vulnerability could affect supply chains and critical services. However, exploitation requires local network access (AV:L), which somewhat limits the attack surface to internal or VPN-connected attackers rather than fully remote internet-based adversaries.

Mitigation Recommendations

1. Immediate mitigation involves upgrading SINEMA Remote Connect Server to version 3.2 SP1 or later once Siemens releases the patch. 2. Until patching is possible, implement network segmentation to restrict access to SINEMA Remote Connect Server devices only to trusted internal hosts and VPN users, minimizing exposure to potential attackers. 3. Monitor system logs and resource utilization metrics closely for unusual spikes in logging activity or resource consumption that could indicate exploitation attempts. 4. Employ rate limiting or firewall rules to restrict excessive connections or requests to the SINEMA Remote Connect Server, reducing the risk of resource exhaustion. 5. Review and configure log rotation policies manually if possible, ensuring logs do not grow indefinitely and consume excessive disk space. 6. Conduct regular backups and have incident response plans ready to restore services quickly in case of DoS events. 7. Educate network administrators and security teams about this vulnerability to ensure rapid detection and response.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
siemens
Date Reserved
2024-07-01T13:05:40.289Z
Cisa Enriched
true
Cvss Version
3.1
State
PUBLISHED

Threat ID: 682d983ac4522896dcbed284

Added to database: 5/21/2025, 9:09:14 AM

Last enriched: 6/25/2025, 3:32:09 PM

Last updated: 7/28/2025, 9:58:19 PM

Views: 12

Actions

PRO

Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.