Skip to main content
Press slash or control plus K to focus the search. Use the arrow keys to navigate results and press enter to open a threat.
Reconnecting to live updates…

CVE-2024-49563: CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in Dell Unity

0
High
VulnerabilityCVE-2024-49563cvecve-2024-49563cwe-78
Published: Fri Mar 28 2025 (03/28/2025, 01:35:58 UTC)
Source: CVE Database V5
Vendor/Project: Dell
Product: Unity

Description

Dell Unity, version(s) 5.4 and prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to execution of arbitrary operating system commands with root privileges and elevation of privileges.

AI-Powered Analysis

AILast updated: 02/26/2026, 21:17:48 UTC

Technical Analysis

CVE-2024-49563 is an OS command injection vulnerability identified in Dell Unity storage systems, specifically versions 5.4 and prior. The vulnerability arises due to improper neutralization of special characters in OS commands, classified under CWE-78. This flaw allows a low-privileged attacker who has local access to the system to inject and execute arbitrary operating system commands with root-level privileges. The vulnerability does not require user interaction and has a CVSS v3.1 base score of 7.8, indicating high severity. The attack vector is local (AV:L), with low attack complexity (AC:L), requiring low privileges (PR:L), and no user interaction (UI:N). The scope is unchanged (S:U), but the impact on confidentiality, integrity, and availability is high (C:H/I:H/A:H). Exploiting this vulnerability could lead to full system compromise, including unauthorized data access, data manipulation, or denial of service. No patches or official remediation guidance have been published yet, and no known exploits have been observed in the wild. Dell Unity is widely used in enterprise storage environments, making this vulnerability critical for organizations relying on these systems for data storage and management.

Potential Impact

The potential impact of CVE-2024-49563 is severe for organizations using Dell Unity storage systems. Successful exploitation grants attackers root-level access, enabling complete control over the affected system. This can lead to unauthorized data access, data corruption, deletion, or ransomware deployment. The attacker could also use the compromised system as a pivot point to move laterally within the network, escalating the breach's scope. Given the critical role of storage arrays in enterprise IT infrastructure, this vulnerability threatens the confidentiality, integrity, and availability of sensitive data and business operations. Organizations in sectors such as finance, healthcare, government, and critical infrastructure that depend on Dell Unity for data storage face heightened risks of operational disruption and data breaches.

Mitigation Recommendations

To mitigate CVE-2024-49563, organizations should implement the following specific measures: 1) Restrict local access to Dell Unity systems strictly to trusted administrators and personnel, employing strong physical and logical access controls. 2) Monitor and audit all local access and command executions on Dell Unity devices to detect suspicious activities promptly. 3) Apply the principle of least privilege rigorously, ensuring users have only the minimum necessary permissions to perform their tasks. 4) Segregate management interfaces and storage systems from general user networks to reduce exposure. 5) Engage with Dell support and subscribe to official security advisories to receive patches or workarounds as soon as they become available. 6) Consider deploying host-based intrusion detection systems (HIDS) on management hosts to detect anomalous command executions. 7) Conduct regular security training for administrators to recognize and prevent exploitation attempts. 8) Implement network segmentation and zero-trust principles around critical storage infrastructure to limit lateral movement in case of compromise.

Need more detailed analysis?Upgrade to Pro Console

Technical Details

Data Version
5.2
Assigner Short Name
dell
Date Reserved
2024-10-16T05:04:26.795Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 69a0a44285912abc71d630ed

Added to database: 2/26/2026, 7:51:30 PM

Last enriched: 2/26/2026, 9:17:48 PM

Last updated: 2/26/2026, 11:16:28 PM

Views: 3

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses