Skip to main content
Press slash or control plus K to focus the search. Use the arrow keys to navigate results and press enter to open a threat.
Reconnecting to live updates…

CVE-2024-49565: CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in Dell Unity

0
High
VulnerabilityCVE-2024-49565cvecve-2024-49565cwe-78
Published: Fri Mar 28 2025 (03/28/2025, 01:28:11 UTC)
Source: CVE Database V5
Vendor/Project: Dell
Product: Unity

Description

Dell Unity, version(s) 5.4 and prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution and Elevation of privileges.

AI-Powered Analysis

AILast updated: 02/26/2026, 21:17:22 UTC

Technical Analysis

CVE-2024-49565 is an OS command injection vulnerability classified under CWE-78, found in Dell Unity storage systems version 5.4 and prior. The flaw arises from improper neutralization of special characters in user-supplied input that is passed to operating system commands. This improper sanitization allows a low-privileged attacker with local access to inject arbitrary commands into the system shell. Successful exploitation enables the attacker to execute OS-level commands with elevated privileges, effectively escalating their access rights beyond their initial permissions. The vulnerability does not require user interaction, but it does require local access with low privileges, which could be achieved through compromised credentials or insider threats. The CVSS v3.1 score of 7.8 indicates high severity, with high impact on confidentiality, integrity, and availability, moderate attack complexity, and low privileges required. Although no public exploits are currently known, the potential for privilege escalation and full system compromise makes this a critical risk for affected organizations. Dell Unity is a popular enterprise storage platform used globally, often in environments requiring high data availability and security, such as financial institutions, healthcare, and government agencies. The lack of available patches at the time of disclosure necessitates immediate mitigation strategies to reduce exposure.

Potential Impact

The impact of CVE-2024-49565 is significant for organizations using Dell Unity storage systems. Exploitation can lead to unauthorized command execution and privilege escalation, potentially allowing attackers to gain full control over the affected storage appliance. This can result in data breaches, data corruption, or denial of service, severely affecting data confidentiality, integrity, and availability. Given the critical role of storage systems in enterprise IT infrastructure, successful exploitation could disrupt business operations, cause financial losses, and damage organizational reputation. The vulnerability also increases the risk of lateral movement within networks, as attackers could leverage compromised storage systems as footholds to access other critical systems. Organizations with multi-tenant environments or shared storage are particularly vulnerable to cross-tenant attacks. The absence of known exploits in the wild provides a window for proactive defense, but the high severity score underscores the urgency of addressing this vulnerability.

Mitigation Recommendations

Organizations should immediately restrict local access to Dell Unity systems to trusted personnel only, employing strict access controls and monitoring. Implement network segmentation to isolate storage systems from general user networks and reduce the attack surface. Employ robust logging and alerting mechanisms to detect unusual command execution or privilege escalation attempts. Until official patches are released by Dell, consider deploying host-based intrusion detection systems (HIDS) or endpoint protection solutions that can identify suspicious command injection patterns. Regularly audit user accounts and permissions to minimize the number of users with local access. Educate administrators and users about the risks of local exploitation and enforce strong authentication mechanisms, such as multi-factor authentication, for accessing storage management interfaces. Once Dell releases patches, prioritize their deployment in all affected environments. Additionally, conduct penetration testing and vulnerability assessments focused on command injection vectors to identify and remediate potential exploitation paths.

Need more detailed analysis?Upgrade to Pro Console

Technical Details

Data Version
5.2
Assigner Short Name
dell
Date Reserved
2024-10-16T05:04:26.796Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 69a0a44285912abc71d630f3

Added to database: 2/26/2026, 7:51:30 PM

Last enriched: 2/26/2026, 9:17:22 PM

Last updated: 2/26/2026, 11:16:15 PM

Views: 4

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses