CVE-2024-7881: CWE-1422: Exposure of Sensitive Information caused by Incorrect Data Forwarding during Transient Execution in Arm Neoverse V2
An unprivileged context can trigger a data memory-dependent prefetch engine to fetch the contents of a privileged location and consume those contents as an address that is also dereferenced.
AI Analysis
Technical Summary
CVE-2024-7881 is a vulnerability in the Arm Neoverse V2 processor architecture involving incorrect data forwarding during transient execution, specifically related to the processor's data memory-dependent prefetch engine. An unprivileged context can trigger this prefetch engine to fetch data from privileged memory locations. The fetched privileged data is then consumed as an address and dereferenced, potentially leaking sensitive information from higher-privileged contexts to lower-privileged ones. This behavior is a form of side-channel attack exploiting transient execution, similar in concept to Spectre-class vulnerabilities, but specific to the Arm Neoverse V2 design. The vulnerability does not require any user interaction or elevated privileges, but exploitation requires local access to the system. The impact is limited to confidentiality leakage, with no direct effect on integrity or availability. No public exploits or patches are currently available, indicating that the vulnerability is newly disclosed and may require microcode or firmware updates from Arm or device manufacturers. The CVSS 3.1 score of 5.1 reflects a medium severity, with attack vector local, low complexity, no privileges required, and no user interaction needed. This vulnerability highlights the risks inherent in speculative and transient execution optimizations in modern CPUs, necessitating careful mitigation strategies.
Potential Impact
For European organizations, the primary impact of CVE-2024-7881 is the potential unauthorized disclosure of sensitive information residing in privileged memory areas. This could include cryptographic keys, system credentials, or other confidential data critical to secure operations. Organizations relying on Arm Neoverse V2-based infrastructure—commonly found in cloud data centers, telecom equipment, and edge computing devices—may face increased risk of insider threats or local attackers gaining access to sensitive data. While the vulnerability does not affect system integrity or availability, the confidentiality breach could undermine trust, lead to regulatory non-compliance (e.g., GDPR), and facilitate further attacks if sensitive credentials are exposed. The requirement for local access limits remote exploitation, but insider threats or compromised local accounts remain a concern. The absence of known exploits in the wild currently reduces immediate risk, but the medium severity rating and lack of patches necessitate proactive risk management. European critical infrastructure sectors, including finance, telecommunications, and government, may be particularly sensitive to such data leaks.
Mitigation Recommendations
Mitigation of CVE-2024-7881 requires a multi-layered approach. First and foremost, organizations should monitor vendor communications closely and apply microcode or firmware updates as soon as they become available from Arm or device manufacturers. Until patches are released, restrict local access to systems running Arm Neoverse V2 processors by enforcing strict access controls, including multi-factor authentication and least privilege principles. Employ robust monitoring and anomaly detection to identify unusual local activities that could indicate exploitation attempts. Consider isolating critical workloads or sensitive data on hardware not affected by this vulnerability or within virtualized environments with strong isolation guarantees. Additionally, implement software-level mitigations such as disabling or limiting speculative execution features if supported and feasible, understanding the potential performance trade-offs. Regularly audit and update security policies to address insider threat risks. Finally, ensure incident response plans include procedures for handling potential data leakage scenarios related to this vulnerability.
Affected Countries
Germany, France, United Kingdom, Netherlands, Sweden, Finland
CVE-2024-7881: CWE-1422: Exposure of Sensitive Information caused by Incorrect Data Forwarding during Transient Execution in Arm Neoverse V2
Description
An unprivileged context can trigger a data memory-dependent prefetch engine to fetch the contents of a privileged location and consume those contents as an address that is also dereferenced.
AI-Powered Analysis
Technical Analysis
CVE-2024-7881 is a vulnerability in the Arm Neoverse V2 processor architecture involving incorrect data forwarding during transient execution, specifically related to the processor's data memory-dependent prefetch engine. An unprivileged context can trigger this prefetch engine to fetch data from privileged memory locations. The fetched privileged data is then consumed as an address and dereferenced, potentially leaking sensitive information from higher-privileged contexts to lower-privileged ones. This behavior is a form of side-channel attack exploiting transient execution, similar in concept to Spectre-class vulnerabilities, but specific to the Arm Neoverse V2 design. The vulnerability does not require any user interaction or elevated privileges, but exploitation requires local access to the system. The impact is limited to confidentiality leakage, with no direct effect on integrity or availability. No public exploits or patches are currently available, indicating that the vulnerability is newly disclosed and may require microcode or firmware updates from Arm or device manufacturers. The CVSS 3.1 score of 5.1 reflects a medium severity, with attack vector local, low complexity, no privileges required, and no user interaction needed. This vulnerability highlights the risks inherent in speculative and transient execution optimizations in modern CPUs, necessitating careful mitigation strategies.
Potential Impact
For European organizations, the primary impact of CVE-2024-7881 is the potential unauthorized disclosure of sensitive information residing in privileged memory areas. This could include cryptographic keys, system credentials, or other confidential data critical to secure operations. Organizations relying on Arm Neoverse V2-based infrastructure—commonly found in cloud data centers, telecom equipment, and edge computing devices—may face increased risk of insider threats or local attackers gaining access to sensitive data. While the vulnerability does not affect system integrity or availability, the confidentiality breach could undermine trust, lead to regulatory non-compliance (e.g., GDPR), and facilitate further attacks if sensitive credentials are exposed. The requirement for local access limits remote exploitation, but insider threats or compromised local accounts remain a concern. The absence of known exploits in the wild currently reduces immediate risk, but the medium severity rating and lack of patches necessitate proactive risk management. European critical infrastructure sectors, including finance, telecommunications, and government, may be particularly sensitive to such data leaks.
Mitigation Recommendations
Mitigation of CVE-2024-7881 requires a multi-layered approach. First and foremost, organizations should monitor vendor communications closely and apply microcode or firmware updates as soon as they become available from Arm or device manufacturers. Until patches are released, restrict local access to systems running Arm Neoverse V2 processors by enforcing strict access controls, including multi-factor authentication and least privilege principles. Employ robust monitoring and anomaly detection to identify unusual local activities that could indicate exploitation attempts. Consider isolating critical workloads or sensitive data on hardware not affected by this vulnerability or within virtualized environments with strong isolation guarantees. Additionally, implement software-level mitigations such as disabling or limiting speculative execution features if supported and feasible, understanding the potential performance trade-offs. Regularly audit and update security policies to address insider threat risks. Finally, ensure incident response plans include procedures for handling potential data leakage scenarios related to this vulnerability.
Affected Countries
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- Arm
- Date Reserved
- 2024-08-16T13:57:21.218Z
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 691c7a583fd37bbc3955e449
Added to database: 11/18/2025, 1:53:28 PM
Last enriched: 11/18/2025, 1:55:30 PM
Last updated: 11/18/2025, 10:04:09 PM
Views: 6
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Related Threats
CVE-2025-63229: n/a
HighCVE-2025-63217: n/a
CriticalCVE-2025-63216: n/a
HighCVE-2025-63215: n/a
CriticalCVE-2025-12119: CWE-825 Expired Pointer Dereference in MongoDB C Driver
MediumActions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
External Links
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.