CVE-2025-11739: Schneider Electric EcoStruxure™ Power Monitoring Expert (PME) · Deserialization of Untrusted Data
Affects Schneider Electric EcoStruxure™ Power Monitoring Expert (PME)Source CVE Database V5
Not known to be exploited · CVSS 8.5 High.
Data as of 29 Oct 2026, 19:04 UTC
- EPSS
- 0.1% chance of exploitation in 30 days – higher than 8% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:NExploitation evidence
Disclosed: evidence found.
CVE published 10 Mar 2026
Detectable: no evidence on record.
No public nuclei template indexed
Weaponized: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 29 Oct 2026.
What to do
Affected software
| Product | Affected | Fixed in |
|---|---|---|
| Schneider ElectricEcoStruxure™ Power Monitoring Expert (PME) | Affected
| Fixed in– |
| Schneider ElectricEcoStruxure™ Power Operation (EPO) Advanced Reporting and Dashboards Module | Affected
| Fixed in– |
AI-suggested
- Restrict local access to PME systems strictly to trusted administrators and personnel to reduce the risk of exploitation.
- Monitor and audit local access logs for unusual or unauthorized activity indicative of attempted exploitation.
- Implement network segmentation to isolate PME systems from less secure network zones, limiting exposure.
- Apply principle of least privilege to all user accounts with access to PME, minimizing privileges where possible.
- Deploy application whitelisting and endpoint protection solutions on PME hosts to detect and block suspicious code execution.
- Once available, promptly apply official patches or updates from Schneider Electric addressing this vulnerability.
- Conduct regular security assessments and penetration testing focusing on deserialization and input validation weaknesses.
- Educate administrators about the risks of deserialization vulnerabilities and safe handling of data streams within PME.
- Consider implementing additional runtime protections such as sandboxing or code integrity checks to mitigate exploitation impact.
Description
CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization.