CVE-2025-12994: CWE-204 Observable Response Discrepancy in Medtronic CareLink Network

0
Medium
VulnerabilityCVE-2025-12994cvecve-2025-12994cwe-204
Published: Thu Dec 04 2025 (12/04/2025, 20:02:06 UTC)
Source: CVE Database V5
Vendor/Project: Medtronic
Product: CareLink Network

Description

Medtronic CareLink Network allows an unauthenticated remote attacker to initiate a request for security questions to an API endpoint that could be used to determine a valid user account. This issue affects CareLink Network: before December 4, 2025.

AI-Powered Analysis

AILast updated: 12/11/2025, 21:52:36 UTC

Technical Analysis

CVE-2025-12994 is a vulnerability classified under CWE-204 (Observable Response Discrepancy) affecting the Medtronic CareLink Network, a platform used for remote monitoring of medical devices. The vulnerability allows an unauthenticated remote attacker to send requests to an API endpoint that triggers security questions. Due to differences in the API's response based on whether the requested user account exists, an attacker can determine valid user accounts through response analysis. This user enumeration flaw does not require any authentication or user interaction, making it easier to exploit remotely over the network. The vulnerability impacts confidentiality by exposing valid user identifiers, which can be leveraged for further attacks such as phishing, credential stuffing, or social engineering. However, it does not affect the integrity or availability of the system. The affected versions include all versions of CareLink Network prior to December 4, 2025. No patches or mitigations have been officially released at the time of publication, and no exploits have been observed in the wild. The CVSS v3.1 base score is 5.3, indicating a medium severity, with attack vector network (AV:N), low attack complexity (AC:L), no privileges required (PR:N), no user interaction (UI:N), and impact limited to confidentiality (C:L). The vulnerability is significant in the context of healthcare cybersecurity, where protecting patient data and device access is critical. The flaw could facilitate reconnaissance activities by attackers targeting healthcare providers using Medtronic devices, potentially leading to more severe attacks if combined with other vulnerabilities or social engineering techniques.

Potential Impact

The primary impact of CVE-2025-12994 on European organizations lies in the exposure of valid user accounts within the Medtronic CareLink Network. This user enumeration vulnerability compromises confidentiality by allowing attackers to identify legitimate users, which can be exploited for targeted phishing campaigns, credential stuffing, or further intrusion attempts. Although the vulnerability does not directly affect system integrity or availability, the information gained can serve as a stepping stone for more sophisticated attacks against healthcare providers. European healthcare institutions relying on CareLink for remote monitoring of medical devices could face increased risks of unauthorized access or data breaches if attackers leverage enumerated accounts. Additionally, the exposure of user information may violate data protection regulations such as GDPR, leading to legal and reputational consequences. The lack of authentication and user interaction requirements lowers the barrier for exploitation, increasing the likelihood of reconnaissance activities. However, the absence of known exploits in the wild and the medium CVSS score suggest that immediate critical impact is limited but should not be underestimated given the sensitivity of healthcare environments.

Mitigation Recommendations

To mitigate CVE-2025-12994 effectively, European organizations should implement the following specific measures: 1) Enforce uniform API response behavior to security question requests, ensuring that responses do not differ based on the existence of user accounts, thereby eliminating observable discrepancies. 2) Deploy rate limiting and anomaly detection on API endpoints to identify and block automated enumeration attempts. 3) Monitor logs for unusual patterns of requests targeting security question APIs, enabling early detection of reconnaissance activities. 4) Restrict API access through network segmentation and firewall rules, limiting exposure to trusted networks or VPNs where possible. 5) Engage with Medtronic for timely patch management and apply updates as soon as they become available. 6) Educate staff and users about phishing risks that may arise from user enumeration and implement multi-factor authentication (MFA) to reduce the risk of account compromise. 7) Conduct regular security assessments and penetration testing focused on API security to identify and remediate similar issues proactively. These targeted actions go beyond generic advice by focusing on eliminating information leakage, enhancing detection, and reducing attack surface specific to this vulnerability.

Need more detailed analysis?Upgrade to Pro Console

Technical Details

Data Version
5.2
Assigner Short Name
Medtronic
Date Reserved
2025-11-11T03:38:43.879Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 6931eb9b6255310dc4c890a4

Added to database: 12/4/2025, 8:14:19 PM

Last enriched: 12/11/2025, 9:52:36 PM

Last updated: 1/19/2026, 7:35:23 AM

Views: 102

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats