CVE-2025-12994VulnerabilityPublished Updated

CVE-2025-12994: Medtronic CareLink Network · Observable Response Discrepancy

Affects Medtronic CareLink NetworkSource CVE Database V5

0

Not known to be exploited · CVSS 5.3 Medium.

Data as of 26 Oct 2026, 06:26 UTC

CVSS 3.1 base score
5.3Medium
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.2% chance of exploitation in 30 days – higher than 22% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 4 Dec 2025

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 2026-10-26.

What to do

Affected software

ProductAffectedFixed in
Medtronic CareLink NetworkAffected
  • =0
Fixed in–

AI-suggested

To mitigate CVE-2025-12994 effectively, European organizations should implement the following specific measures: 1) Enforce uniform API response behavior to security question requests, ensuring that responses do not differ based on the existence of user accounts, thereby eliminating observable discrepancies. 2) Deploy rate limiting and anomaly detection on API endpoints to identify and block automated enumeration attempts. 3) Monitor logs for unusual patterns of requests targeting security question APIs, enabling early detection of reconnaissance activities. 4) Restrict API access through network segmentation and firewall rules, limiting exposure to trusted networks or VPNs where possible. 5) Engage with Medtronic for timely patch management and apply updates as soon as they become available. 6) Educate staff and users about phishing risks that may arise from user enumeration and implement multi-factor authentication (MFA) to reduce the risk of account compromise. 7) Conduct regular security assessments and penetration testing focused on API security to identify and remediate similar issues proactively. These targeted actions go beyond generic advice by focusing on eliminating information leakage, enhancing detection, and reducing attack surface specific to this vulnerability.

Description

Medtronic CareLink Network allows an unauthenticated remote attacker to initiate a request for security questions to an API endpoint that could be used to determine a valid user account. This issue affects CareLink Network: before December 4, 2025.