CVE-2025-12994: CWE-204 Observable Response Discrepancy in Medtronic CareLink Network
Medtronic CareLink Network allows an unauthenticated remote attacker to initiate a request for security questions to an API endpoint that could be used to determine a valid user account. This issue affects CareLink Network: before December 4, 2025.
AI Analysis
Technical Summary
CVE-2025-12994 identifies a security weakness in the Medtronic CareLink Network, a platform used for managing and monitoring medical devices remotely. The vulnerability is classified under CWE-204, which involves observable response discrepancies that allow attackers to infer sensitive information. Specifically, an unauthenticated remote attacker can send requests to an API endpoint designed to trigger security questions. The system’s responses differ depending on whether the requested user account exists, enabling the attacker to enumerate valid user accounts without authentication or user interaction. This form of user enumeration can be leveraged as a reconnaissance step in more complex attack chains, such as targeted phishing campaigns or brute force attempts against identified accounts. The vulnerability affects all versions of CareLink Network prior to December 4, 2025. The CVSS v3.1 base score is 5.3, indicating medium severity, with the vector highlighting network attack vector, low attack complexity, no privileges or user interaction required, and limited confidentiality impact. There are no known exploits in the wild, and no official patches have been released at the time of publication. The vulnerability primarily threatens confidentiality by exposing valid user identities, which is critical in healthcare environments where patient data privacy is paramount. The lack of integrity or availability impact reduces the immediate risk of system disruption or data manipulation. However, the ability to enumerate users can facilitate subsequent attacks that may have more severe consequences. The vulnerability underscores the importance of secure API design, particularly in sensitive sectors like healthcare, where information disclosure can have serious privacy and compliance implications.
Potential Impact
For European organizations, especially healthcare providers using Medtronic CareLink Network, this vulnerability poses a significant privacy risk. The ability to enumerate valid user accounts can lead to targeted phishing attacks, social engineering, or credential stuffing, potentially compromising patient data confidentiality. Given the sensitive nature of medical device management and patient health information, unauthorized access or exposure could violate GDPR and other data protection regulations, resulting in legal and financial repercussions. While the vulnerability does not directly affect system integrity or availability, the indirect consequences of user enumeration can escalate into more damaging attacks. European healthcare institutions are often high-value targets due to the critical services they provide and the sensitive data they hold. This vulnerability could also undermine patient trust and the reputation of affected organizations. Additionally, attackers could leverage enumerated accounts to attempt unauthorized access to medical devices, potentially impacting patient safety. The medium severity rating suggests that while immediate exploitation impact is limited, the broader implications for patient privacy and regulatory compliance are substantial.
Mitigation Recommendations
1. Monitor and analyze API traffic for unusual patterns indicative of automated user enumeration attempts, such as repeated requests for security questions from the same IP addresses. 2. Implement rate limiting and throttling on API endpoints that handle security questions or user verification to reduce the feasibility of enumeration attacks. 3. Employ generic error messages and uniform response times for API requests related to user verification to prevent attackers from distinguishing valid from invalid accounts. 4. Enforce multi-factor authentication (MFA) for user accounts to mitigate risks from subsequent credential-based attacks. 5. Once available, promptly apply official patches or updates released by Medtronic addressing this vulnerability. 6. Conduct regular security assessments and penetration testing focused on API endpoints to identify and remediate similar information disclosure issues. 7. Educate staff and users on phishing risks and encourage vigilance against suspicious communications that may leverage enumerated user information. 8. Collaborate with Medtronic and healthcare cybersecurity communities to share threat intelligence and best practices related to this vulnerability. 9. Review and update incident response plans to include scenarios involving user enumeration and potential follow-on attacks targeting medical device management systems.
Affected Countries
Germany, France, United Kingdom, Italy, Spain, Netherlands, Sweden
CVE-2025-12994: CWE-204 Observable Response Discrepancy in Medtronic CareLink Network
Description
Medtronic CareLink Network allows an unauthenticated remote attacker to initiate a request for security questions to an API endpoint that could be used to determine a valid user account. This issue affects CareLink Network: before December 4, 2025.
AI-Powered Analysis
Technical Analysis
CVE-2025-12994 identifies a security weakness in the Medtronic CareLink Network, a platform used for managing and monitoring medical devices remotely. The vulnerability is classified under CWE-204, which involves observable response discrepancies that allow attackers to infer sensitive information. Specifically, an unauthenticated remote attacker can send requests to an API endpoint designed to trigger security questions. The system’s responses differ depending on whether the requested user account exists, enabling the attacker to enumerate valid user accounts without authentication or user interaction. This form of user enumeration can be leveraged as a reconnaissance step in more complex attack chains, such as targeted phishing campaigns or brute force attempts against identified accounts. The vulnerability affects all versions of CareLink Network prior to December 4, 2025. The CVSS v3.1 base score is 5.3, indicating medium severity, with the vector highlighting network attack vector, low attack complexity, no privileges or user interaction required, and limited confidentiality impact. There are no known exploits in the wild, and no official patches have been released at the time of publication. The vulnerability primarily threatens confidentiality by exposing valid user identities, which is critical in healthcare environments where patient data privacy is paramount. The lack of integrity or availability impact reduces the immediate risk of system disruption or data manipulation. However, the ability to enumerate users can facilitate subsequent attacks that may have more severe consequences. The vulnerability underscores the importance of secure API design, particularly in sensitive sectors like healthcare, where information disclosure can have serious privacy and compliance implications.
Potential Impact
For European organizations, especially healthcare providers using Medtronic CareLink Network, this vulnerability poses a significant privacy risk. The ability to enumerate valid user accounts can lead to targeted phishing attacks, social engineering, or credential stuffing, potentially compromising patient data confidentiality. Given the sensitive nature of medical device management and patient health information, unauthorized access or exposure could violate GDPR and other data protection regulations, resulting in legal and financial repercussions. While the vulnerability does not directly affect system integrity or availability, the indirect consequences of user enumeration can escalate into more damaging attacks. European healthcare institutions are often high-value targets due to the critical services they provide and the sensitive data they hold. This vulnerability could also undermine patient trust and the reputation of affected organizations. Additionally, attackers could leverage enumerated accounts to attempt unauthorized access to medical devices, potentially impacting patient safety. The medium severity rating suggests that while immediate exploitation impact is limited, the broader implications for patient privacy and regulatory compliance are substantial.
Mitigation Recommendations
1. Monitor and analyze API traffic for unusual patterns indicative of automated user enumeration attempts, such as repeated requests for security questions from the same IP addresses. 2. Implement rate limiting and throttling on API endpoints that handle security questions or user verification to reduce the feasibility of enumeration attacks. 3. Employ generic error messages and uniform response times for API requests related to user verification to prevent attackers from distinguishing valid from invalid accounts. 4. Enforce multi-factor authentication (MFA) for user accounts to mitigate risks from subsequent credential-based attacks. 5. Once available, promptly apply official patches or updates released by Medtronic addressing this vulnerability. 6. Conduct regular security assessments and penetration testing focused on API endpoints to identify and remediate similar information disclosure issues. 7. Educate staff and users on phishing risks and encourage vigilance against suspicious communications that may leverage enumerated user information. 8. Collaborate with Medtronic and healthcare cybersecurity communities to share threat intelligence and best practices related to this vulnerability. 9. Review and update incident response plans to include scenarios involving user enumeration and potential follow-on attacks targeting medical device management systems.
Affected Countries
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- Medtronic
- Date Reserved
- 2025-11-11T03:38:43.879Z
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 6931eb9b6255310dc4c890a4
Added to database: 12/4/2025, 8:14:19 PM
Last enriched: 12/4/2025, 8:25:58 PM
Last updated: 12/5/2025, 2:37:55 AM
Views: 10
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Related Threats
CVE-2025-12804: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in wpdevelop Booking Calendar
MediumCVE-2025-11759: CWE-352 Cross-Site Request Forgery (CSRF) in watchful Backup, Restore and Migrate your sites with XCloner
MediumCVE-2025-62223: CWE-451: User Interface (UI) Misrepresentation of Critical Information in Microsoft Microsoft Edge (Chromium-based)
MediumCVE-2025-14052: Improper Access Controls in youlaitech youlai-mall
MediumCVE-2025-13373: CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') in Advantech iView
HighActions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
External Links
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.