CVE-2025-12997: CWE-639 Authorization Bypass Through User-Controlled Key in Medtronic CareLink Network

0
Low
VulnerabilityCVE-2025-12997cvecve-2025-12997cwe-639
Published: Thu Dec 04 2025 (12/04/2025, 20:04:26 UTC)
Source: CVE Database V5
Vendor/Project: Medtronic
Product: CareLink Network

Description

Insecure Direct Object Reference vulnerability in Medtronic CareLink Network which allows an authenticated attacker with access to specific device and user information to submit web requests to an API endpoint that would expose sensitive user information. This issue affects CareLink Network: before December 4, 2025.

AI-Powered Analysis

AILast updated: 12/04/2025, 20:25:34 UTC

Technical Analysis

CVE-2025-12997 is an Insecure Direct Object Reference (IDOR) vulnerability in the Medtronic CareLink Network, a platform used for managing and monitoring medical devices such as insulin pumps and cardiac devices. The vulnerability arises because the API endpoint improperly authorizes requests when provided with user-controlled keys, allowing an authenticated attacker who already has access to certain device and user identifiers to submit crafted web requests that expose sensitive user information. This flaw is categorized under CWE-639, which relates to authorization bypass through user-controlled keys. The vulnerability affects all versions of CareLink Network prior to December 4, 2025. The CVSS v3.1 base score is 2.2, reflecting a low severity primarily due to the requirement of authenticated access with high privileges and the limited confidentiality impact. There is no impact on system integrity or availability. No public exploits have been reported, and no patches are currently available, though the vendor has reserved the CVE and is presumably working on remediation. The vulnerability highlights the importance of robust authorization checks on API endpoints, especially in healthcare environments where sensitive personal and medical data is involved.

Potential Impact

The primary impact of CVE-2025-12997 is the potential unauthorized disclosure of sensitive patient information within the Medtronic CareLink Network. While the attacker must already be authenticated with high privileges and possess specific device and user information, successful exploitation could lead to privacy violations and potential regulatory non-compliance under GDPR for European healthcare providers. The confidentiality breach could undermine patient trust and expose organizations to legal and reputational risks. However, the vulnerability does not affect the integrity or availability of medical devices or the network, so direct harm to patient health or device functionality is unlikely. European healthcare organizations relying on Medtronic CareLink for device management and patient monitoring are the primary stakeholders at risk. The impact is mitigated somewhat by the need for authenticated access and the complexity of exploiting the flaw without additional information.

Mitigation Recommendations

1. Implement strict access control policies ensuring that only authorized personnel with a legitimate need can access device and user information within the CareLink Network. 2. Monitor API endpoint usage for anomalous or unauthorized requests, especially those involving user-controlled keys or identifiers. 3. Enforce least privilege principles to limit the scope of authenticated users who can access sensitive API endpoints. 4. Conduct regular audits of user permissions and API access logs to detect potential misuse. 5. Upon availability, promptly apply vendor patches or updates addressing CVE-2025-12997. 6. Employ multi-factor authentication (MFA) to reduce the risk of compromised credentials being used to exploit the vulnerability. 7. Educate staff about the importance of safeguarding device and user information to prevent attackers from obtaining the necessary identifiers. 8. Consider network segmentation to isolate medical device management systems from broader enterprise networks to limit lateral movement.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.2
Assigner Short Name
Medtronic
Date Reserved
2025-11-11T03:38:47.476Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 6931eb9b6255310dc4c890ad

Added to database: 12/4/2025, 8:14:19 PM

Last enriched: 12/4/2025, 8:25:34 PM

Last updated: 12/5/2025, 1:57:57 AM

Views: 9

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.

Latest Threats