CVE-2025-12997: CWE-639 Authorization Bypass Through User-Controlled Key in Medtronic CareLink Network

0
Low
VulnerabilityCVE-2025-12997cvecve-2025-12997cwe-639
Published: Thu Dec 04 2025 (12/04/2025, 20:04:26 UTC)
Source: CVE Database V5
Vendor/Project: Medtronic
Product: CareLink Network

Description

Insecure Direct Object Reference vulnerability in Medtronic CareLink Network which allows an authenticated attacker with access to specific device and user information to submit web requests to an API endpoint that would expose sensitive user information. This issue affects CareLink Network: before December 4, 2025.

AI-Powered Analysis

AILast updated: 12/11/2025, 21:44:05 UTC

Technical Analysis

CVE-2025-12997 is classified as an Insecure Direct Object Reference (IDOR) vulnerability (CWE-639) in the Medtronic CareLink Network, a widely used platform for remote monitoring and management of Medtronic medical devices. The vulnerability arises because the API endpoint improperly authorizes requests based on user-controlled keys or identifiers, allowing an authenticated attacker who already has access to specific device and user information to craft web requests that bypass authorization checks. This can lead to unauthorized disclosure of sensitive user information, such as patient data linked to medical devices. The vulnerability affects all versions of CareLink Network before December 4, 2025, and does not require user interaction but does require the attacker to have authenticated access with a high level of privileges or knowledge of device/user identifiers. The CVSS v3.1 base score is 2.2, reflecting a low severity primarily due to the requirement for authentication and high attack complexity, as well as the limited confidentiality impact and no impact on integrity or availability. No public exploits or active exploitation have been reported to date. The vulnerability highlights the importance of proper authorization checks on API endpoints, especially in healthcare environments where patient data confidentiality is critical. Medtronic has not yet published patches but organizations should prepare to apply updates promptly once available.

Potential Impact

For European organizations, particularly healthcare providers and institutions using Medtronic CareLink Network, this vulnerability poses a risk of unauthorized access to sensitive patient information. Although the impact is rated low, unauthorized disclosure of medical data can have serious privacy and regulatory consequences under GDPR and other data protection laws. The exposure of patient data could lead to loss of patient trust, potential legal liabilities, and compliance issues. Since the vulnerability requires authenticated access, the threat is primarily from insiders or attackers who have already compromised user credentials. The lack of impact on device integrity or availability reduces the risk of direct harm to patients from device malfunction. However, the confidentiality breach alone is significant in the healthcare context. European healthcare organizations must consider this vulnerability within their broader risk management and incident response frameworks.

Mitigation Recommendations

1. Implement strict role-based access controls (RBAC) and least privilege principles to limit authenticated user permissions to only necessary data and functions. 2. Enforce server-side authorization checks that validate user permissions against requested resources, ensuring user-controlled keys cannot be manipulated to access unauthorized data. 3. Monitor API access logs for unusual or suspicious request patterns that may indicate attempts to exploit IDOR vulnerabilities. 4. Conduct regular security assessments and penetration testing focused on API endpoints to detect similar authorization weaknesses. 5. Educate staff and administrators on the importance of credential security to prevent unauthorized authenticated access. 6. Prepare to apply vendor patches or updates promptly once Medtronic releases them addressing this vulnerability. 7. Consider implementing additional data encryption and anonymization techniques to protect sensitive patient information in transit and at rest. 8. Use multi-factor authentication (MFA) to reduce the risk of credential compromise.

Need more detailed analysis?Upgrade to Pro Console

Technical Details

Data Version
5.2
Assigner Short Name
Medtronic
Date Reserved
2025-11-11T03:38:47.476Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 6931eb9b6255310dc4c890ad

Added to database: 12/4/2025, 8:14:19 PM

Last enriched: 12/11/2025, 9:44:05 PM

Last updated: 1/19/2026, 5:16:28 AM

Views: 87

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats