Skip to main content

CVE-2025-23177: CWE-427: Uncontrolled Search Path Element in Ribbon Communications Apollo 9608

High
VulnerabilityCVE-2025-23177cvecve-2025-23177cwe-427
Published: Tue Apr 29 2025 (04/29/2025, 16:01:40 UTC)
Source: CVE
Vendor/Project: Ribbon Communications
Product: Apollo 9608

Description

CWE-427: Uncontrolled Search Path Element

AI-Powered Analysis

AILast updated: 06/25/2025, 02:05:45 UTC

Technical Analysis

CVE-2025-23177 is a high-severity vulnerability identified in Ribbon Communications' Apollo 9608 product, specifically affecting version 9.6R3. The vulnerability is classified under CWE-427, which pertains to an Uncontrolled Search Path Element. This type of vulnerability occurs when software uses an insecure search path to locate executable files or libraries, allowing an attacker to influence the path and potentially execute malicious code. In this case, the Apollo 9608 device improperly handles the search path for critical components, which can be exploited remotely (as indicated by the CVSS vector AV:N) with low attack complexity (AC:L) and requiring low privileges (PR:L), but no user interaction (UI:N). The vulnerability impacts confidentiality and integrity to a limited extent (C:L, I:L) but has a significant impact on availability (A:H), suggesting that exploitation could lead to denial-of-service conditions or disruption of communications. The scope is unchanged (S:U), meaning the impact is confined to the vulnerable component without affecting other system components. No known exploits are currently reported in the wild, and no patches have been linked yet. The vulnerability was published on April 29, 2025, with the reservation date of January 12, 2025, indicating recent discovery and disclosure. Ribbon Communications Apollo 9608 is a telecommunication device often used in enterprise and service provider environments for voice and data communication, making this vulnerability particularly relevant for organizations relying on this hardware for critical communications infrastructure.

Potential Impact

For European organizations, the exploitation of CVE-2025-23177 could lead to significant disruption of telecommunication services, affecting voice and data communication reliability. Given the high impact on availability, attackers could cause denial-of-service conditions, leading to operational downtime and potential loss of business continuity. The limited but present impact on confidentiality and integrity means that sensitive communication data could be exposed or altered, posing risks to privacy and data protection compliance under regulations such as GDPR. Organizations in sectors heavily dependent on uninterrupted communication—such as finance, healthcare, government, and critical infrastructure—would be particularly vulnerable. The requirement for low privileges to exploit the vulnerability increases the risk that insider threats or attackers who have gained limited access could leverage this flaw to escalate their impact. The absence of known exploits in the wild provides a window for proactive mitigation, but the lack of available patches necessitates immediate risk management measures.

Mitigation Recommendations

1. Network Segmentation: Isolate Apollo 9608 devices within dedicated network segments with strict access controls to limit exposure to untrusted networks and reduce the attack surface. 2. Privilege Restriction: Enforce the principle of least privilege on accounts that can access or manage the Apollo 9608 devices to minimize the risk posed by low-privilege exploitation. 3. Monitoring and Logging: Implement enhanced monitoring of device logs and network traffic for unusual activities indicative of exploitation attempts, such as unexpected process executions or path modifications. 4. Configuration Review: Audit and harden the device configuration to ensure that search paths for executables and libraries are explicitly defined and do not include insecure or user-writable directories. 5. Vendor Engagement: Maintain close communication with Ribbon Communications for timely receipt of patches or official mitigation guidance and apply updates promptly once available. 6. Incident Response Preparation: Develop and test incident response plans specific to telecommunication device compromise scenarios to ensure rapid containment and recovery. 7. Access Control: Use network-level controls such as firewalls and VPNs to restrict management access to Apollo 9608 devices only to trusted administrators and management systems. 8. Alternative Communication Channels: Establish backup communication methods to maintain operational continuity in case of device unavailability due to exploitation.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
INCD
Date Reserved
2025-01-12T08:45:19.974Z
Cisa Enriched
true
Cvss Version
3.1
State
PUBLISHED

Threat ID: 682d983cc4522896dcbee984

Added to database: 5/21/2025, 9:09:16 AM

Last enriched: 6/25/2025, 2:05:45 AM

Last updated: 8/12/2025, 2:29:04 PM

Views: 9

Actions

PRO

Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.