CVE-2025-2605: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in Honeywell MB-Secure
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Honeywell MB-Secure allows Privilege Abuse. This issue affects MB-Secure: from V11.04 before V12.53 and MB-Secure PRO from V01.06 before V03.09.Honeywell also recommends updating to the most recent version of this product.
AI Analysis
Technical Summary
CVE-2025-2605 is a critical OS command injection vulnerability (CWE-78) identified in Honeywell's MB-Secure and MB-Secure PRO products. This vulnerability arises from improper neutralization of special elements in OS commands, allowing an attacker with limited privileges (PR:L) to execute arbitrary operating system commands without requiring user interaction (UI:N). The vulnerability affects MB-Secure versions from V11.04 up to but not including V12.53, and MB-Secure PRO versions from V01.06 up to but not including V03.09. Exploitation of this flaw can lead to complete compromise of confidentiality, integrity, and availability (C:I:A all high), as the attacker can abuse privileges to execute commands that could manipulate system files, extract sensitive data, disrupt services, or pivot within the network. The CVSS 3.1 base score of 9.9 reflects the critical nature of this vulnerability, with network attack vector (AV:N), low attack complexity (AC:L), and scope change (S:C), indicating that the vulnerability can affect resources beyond the initially compromised component. Although no known exploits are currently reported in the wild, the severity and ease of exploitation make this a high-risk issue requiring immediate attention. Honeywell recommends updating to the latest versions beyond the affected ranges to remediate this vulnerability. The lack of available patches at the time of reporting suggests organizations should prioritize mitigation strategies and monitor for vendor updates.
Potential Impact
For European organizations, the impact of CVE-2025-2605 is significant, especially for those relying on Honeywell MB-Secure products for critical infrastructure security and industrial control systems. Successful exploitation could lead to unauthorized command execution, resulting in data breaches, operational disruptions, and potential sabotage of industrial processes. Given Honeywell's prominence in sectors such as energy, manufacturing, and building management across Europe, exploitation could affect critical infrastructure, causing cascading effects on public safety and economic stability. The vulnerability's ability to escalate privileges and affect system integrity and availability poses risks to compliance with stringent European data protection regulations (e.g., GDPR) and critical infrastructure protection directives (e.g., NIS Directive). Additionally, the cross-scope impact means that attackers could leverage this vulnerability to move laterally within networks, increasing the attack surface and complicating incident response efforts.
Mitigation Recommendations
European organizations should immediately assess their deployment of Honeywell MB-Secure and MB-Secure PRO products to identify affected versions. Until official patches beyond V12.53 (MB-Secure) and V03.09 (MB-Secure PRO) are applied, organizations should implement strict network segmentation to isolate vulnerable systems from broader enterprise networks, limiting potential lateral movement. Employ application whitelisting and strict command execution policies to detect and block unauthorized OS command invocations. Monitor system and application logs for unusual command execution patterns indicative of exploitation attempts. Enforce least privilege principles rigorously to minimize the privileges of users and service accounts interacting with MB-Secure products. Additionally, deploy intrusion detection/prevention systems (IDS/IPS) with signatures or heuristics targeting OS command injection attempts. Engage with Honeywell support channels to obtain timely updates and patches, and validate the integrity of updates before deployment. Finally, conduct targeted penetration testing and vulnerability scanning focused on this CVE to proactively identify exploitation attempts.
Affected Countries
Germany, France, United Kingdom, Italy, Spain, Netherlands, Belgium, Sweden, Poland, Czech Republic
CVE-2025-2605: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in Honeywell MB-Secure
Description
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Honeywell MB-Secure allows Privilege Abuse. This issue affects MB-Secure: from V11.04 before V12.53 and MB-Secure PRO from V01.06 before V03.09.Honeywell also recommends updating to the most recent version of this product.
AI-Powered Analysis
Technical Analysis
CVE-2025-2605 is a critical OS command injection vulnerability (CWE-78) identified in Honeywell's MB-Secure and MB-Secure PRO products. This vulnerability arises from improper neutralization of special elements in OS commands, allowing an attacker with limited privileges (PR:L) to execute arbitrary operating system commands without requiring user interaction (UI:N). The vulnerability affects MB-Secure versions from V11.04 up to but not including V12.53, and MB-Secure PRO versions from V01.06 up to but not including V03.09. Exploitation of this flaw can lead to complete compromise of confidentiality, integrity, and availability (C:I:A all high), as the attacker can abuse privileges to execute commands that could manipulate system files, extract sensitive data, disrupt services, or pivot within the network. The CVSS 3.1 base score of 9.9 reflects the critical nature of this vulnerability, with network attack vector (AV:N), low attack complexity (AC:L), and scope change (S:C), indicating that the vulnerability can affect resources beyond the initially compromised component. Although no known exploits are currently reported in the wild, the severity and ease of exploitation make this a high-risk issue requiring immediate attention. Honeywell recommends updating to the latest versions beyond the affected ranges to remediate this vulnerability. The lack of available patches at the time of reporting suggests organizations should prioritize mitigation strategies and monitor for vendor updates.
Potential Impact
For European organizations, the impact of CVE-2025-2605 is significant, especially for those relying on Honeywell MB-Secure products for critical infrastructure security and industrial control systems. Successful exploitation could lead to unauthorized command execution, resulting in data breaches, operational disruptions, and potential sabotage of industrial processes. Given Honeywell's prominence in sectors such as energy, manufacturing, and building management across Europe, exploitation could affect critical infrastructure, causing cascading effects on public safety and economic stability. The vulnerability's ability to escalate privileges and affect system integrity and availability poses risks to compliance with stringent European data protection regulations (e.g., GDPR) and critical infrastructure protection directives (e.g., NIS Directive). Additionally, the cross-scope impact means that attackers could leverage this vulnerability to move laterally within networks, increasing the attack surface and complicating incident response efforts.
Mitigation Recommendations
European organizations should immediately assess their deployment of Honeywell MB-Secure and MB-Secure PRO products to identify affected versions. Until official patches beyond V12.53 (MB-Secure) and V03.09 (MB-Secure PRO) are applied, organizations should implement strict network segmentation to isolate vulnerable systems from broader enterprise networks, limiting potential lateral movement. Employ application whitelisting and strict command execution policies to detect and block unauthorized OS command invocations. Monitor system and application logs for unusual command execution patterns indicative of exploitation attempts. Enforce least privilege principles rigorously to minimize the privileges of users and service accounts interacting with MB-Secure products. Additionally, deploy intrusion detection/prevention systems (IDS/IPS) with signatures or heuristics targeting OS command injection attempts. Engage with Honeywell support channels to obtain timely updates and patches, and validate the integrity of updates before deployment. Finally, conduct targeted penetration testing and vulnerability scanning focused on this CVE to proactively identify exploitation attempts.
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- Honeywell
- Date Reserved
- 2025-03-21T13:18:29.509Z
- Cisa Enriched
- true
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 682cd0f81484d88663aeb8a7
Added to database: 5/20/2025, 6:59:04 PM
Last enriched: 7/11/2025, 9:16:11 PM
Last updated: 7/31/2025, 12:46:58 PM
Views: 11
Related Threats
CVE-2025-9091: Hard-coded Credentials in Tenda AC20
LowCVE-2025-9090: Command Injection in Tenda AC20
MediumCVE-2025-9092: CWE-400 Uncontrolled Resource Consumption in Legion of the Bouncy Castle Inc. Bouncy Castle for Java - BC-FJA 2.1.0
LowCVE-2025-9089: Stack-based Buffer Overflow in Tenda AC20
HighCVE-2025-9088: Stack-based Buffer Overflow in Tenda AC20
HighActions
Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.