Skip to main content

CVE-2025-28200: n/a

Critical
VulnerabilityCVE-2025-28200cvecve-2025-28200
Published: Fri May 09 2025 (05/09/2025, 00:00:00 UTC)
Source: CVE
Vendor/Project: n/a
Product: n/a

Description

Victure RX1800 EN_V1.0.0_r12_110933 was discovered to utilize a weak default password which includes the last 8 digits of the Mac address.

AI-Powered Analysis

AILast updated: 07/12/2025, 02:32:06 UTC

Technical Analysis

CVE-2025-28200 identifies a critical vulnerability in the Victure RX1800 device running firmware version EN_V1.0.0_r12_110933. The core issue stems from the use of a weak default password scheme, where the default password is derived from the last 8 digits of the device's MAC address. This practice significantly reduces password entropy and makes it trivial for an attacker to guess or compute the default password once the MAC address is known or can be discovered through network scanning or physical access. The vulnerability is classified under CWE-521, which relates to the use of weak passwords. According to the CVSS 3.1 scoring, this vulnerability has a score of 9.8 (critical), reflecting its high impact and ease of exploitation. The vector metrics indicate that the attack can be performed remotely (AV:N), requires no privileges (PR:N), no user interaction (UI:N), and affects confidentiality, integrity, and availability (C:H/I:H/A:H). Exploiting this vulnerability allows an attacker to gain unauthorized access to the device, potentially leading to full compromise. This could enable attackers to manipulate device configurations, intercept or alter data, disrupt services, or use the device as a foothold for lateral movement within a network. Although no known exploits are currently reported in the wild, the simplicity of the attack and the critical severity suggest that exploitation could be straightforward once the device is identified. The lack of vendor or product-specific information beyond the device model and firmware version limits detailed contextual analysis, but the vulnerability is clearly severe and demands immediate attention.

Potential Impact

For European organizations, the impact of this vulnerability is significant, especially for those deploying Victure RX1800 devices in their infrastructure. Unauthorized access to these devices could lead to severe breaches of confidentiality, integrity, and availability of network services. This could result in data theft, espionage, disruption of critical operations, or use of compromised devices as pivot points for further attacks within corporate or governmental networks. Organizations in sectors such as telecommunications, critical infrastructure, healthcare, and government are particularly at risk due to the potential for operational disruption and data compromise. Additionally, the widespread use of IoT and networked devices in European enterprises increases the attack surface, making this vulnerability a potential vector for large-scale attacks. The critical severity and remote exploitability mean that attackers do not require physical access or user interaction, increasing the likelihood of automated scanning and exploitation attempts. Furthermore, the absence of patches or vendor guidance at the time of disclosure exacerbates the risk, leaving organizations exposed until mitigations are implemented.

Mitigation Recommendations

To mitigate this vulnerability, European organizations should immediately identify all Victure RX1800 devices within their networks. Network inventory and asset management tools can assist in this discovery. Once identified, organizations should change the default passwords to strong, unique passwords that do not derive from predictable device attributes such as MAC addresses. Implementing network segmentation can limit the exposure of vulnerable devices to untrusted networks. Employing network access controls and monitoring for unusual authentication attempts can help detect exploitation attempts. Where possible, disable remote management interfaces or restrict access to trusted IP addresses. Organizations should also engage with the device vendor or supplier to obtain firmware updates or patches addressing this vulnerability. In the absence of official patches, consider isolating affected devices or replacing them with more secure alternatives. Additionally, educating IT staff about the risks of weak default credentials and enforcing strict password policies for all network devices is essential to prevent similar vulnerabilities. Continuous monitoring and incident response readiness should be enhanced to quickly identify and respond to any exploitation attempts.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
mitre
Date Reserved
2025-03-11T00:00:00.000Z
Cisa Enriched
true
Cvss Version
3.1
State
PUBLISHED

Threat ID: 682d9816c4522896dcbd6776

Added to database: 5/21/2025, 9:08:38 AM

Last enriched: 7/12/2025, 2:32:06 AM

Last updated: 7/28/2025, 4:28:00 PM

Views: 13