Incorrect access control in BW Broadcast TX600 (14980), TX300 (32990) (31448), TX150, TX1000, TX30, and TX50 Hardware Version: 2, Software Version: 1.6.0, Control Version: 1.0, AIO Firmware Version: 1.7 allows attackers to access log files and extract session identifiers to execute a session hijacking attack.

AI-Powered Analysis

AILast updated: 06/21/2025, 13:23:42 UTC

Technical Analysis

CVE-2025-28233 is a critical vulnerability affecting multiple models of BW Broadcast hardware devices, specifically the TX600, TX300, TX150, TX1000, TX30, and TX50. These devices run Hardware Version 2, Software Version 1.6.0, Control Version 1.0, and AIO Firmware Version 1.7. The vulnerability arises from incorrect access control mechanisms that allow unauthorized attackers to access sensitive log files. These log files contain session identifiers, which can be extracted by the attacker to perform session hijacking attacks. The vulnerability is classified under CWE-284 (Improper Access Control), indicating that the devices fail to properly restrict access to sensitive resources. According to the CVSS v3.1 score of 9.1, this vulnerability is critical, with an attack vector of network (AV:N), low attack complexity (AC:L), no privileges required (PR:N), no user interaction (UI:N), and impacts confidentiality and integrity at a high level (C:H/I:H), but does not affect availability (A:N). This means an attacker can remotely exploit this vulnerability without authentication or user interaction, making it highly dangerous. The exploitation allows attackers to hijack active sessions, potentially gaining unauthorized control or access to the device or connected systems. Although no known exploits are currently reported in the wild, the vulnerability's nature and ease of exploitation make it a significant threat. The lack of patch links suggests that a fix may not yet be publicly available, increasing the urgency for mitigation and monitoring. The affected devices are specialized broadcast hardware, likely used in media, telecommunications, or related industries where secure session management is critical.

Potential Impact

For European organizations, particularly those in the broadcasting, telecommunications, and media sectors, this vulnerability poses a severe risk. Unauthorized access to session identifiers can lead to session hijacking, allowing attackers to impersonate legitimate users or administrators. This can result in unauthorized control over broadcast equipment, manipulation or interception of broadcast content, leakage of sensitive operational data, and potential disruption of services. The confidentiality and integrity of broadcast streams and management interfaces are at risk, which could undermine trust and compliance with data protection regulations such as GDPR. Additionally, compromised broadcast infrastructure could be leveraged for further attacks within an organization's network or to spread misinformation. The criticality of this vulnerability is heightened by the fact that exploitation requires no authentication or user interaction, enabling remote attackers to act stealthily and at scale. Organizations relying on these BW Broadcast devices must consider the operational and reputational impacts of potential breaches, including regulatory penalties and loss of audience or customer confidence.

Mitigation Recommendations

Given the absence of publicly available patches, European organizations should implement immediate compensating controls. First, restrict network access to the affected devices by placing them behind firewalls or network segmentation, limiting exposure to trusted management networks only. Employ strict access control lists (ACLs) to block unauthorized IP addresses and protocols. Monitor network traffic for unusual access patterns or attempts to retrieve log files. Enable detailed logging and alerting on access to sensitive resources within the devices, if supported. Where possible, disable or restrict remote management interfaces until patches are available. Conduct regular audits of device firmware and software versions to identify and inventory vulnerable devices. Engage with the device vendor or supplier to obtain timelines for patches or firmware updates and request guidance on interim security measures. Additionally, implement session management best practices in the broader network environment, such as using multi-factor authentication for administrative access and employing network intrusion detection systems (NIDS) to detect session hijacking attempts. Finally, prepare incident response plans specific to broadcast infrastructure compromise to minimize impact if exploitation occurs.

Need more detailed analysis?Upgrade to Pro Console

Technical Details

Data Version
5.1
Assigner Short Name
mitre
Date Reserved
2025-03-11T00:00:00.000Z
Cisa Enriched
true

Threat ID: 682d984ac4522896dcbf751c

Added to database: 5/21/2025, 9:09:30 AM

Last enriched: 6/21/2025, 1:23:42 PM

Last updated: 1/7/2026, 8:54:09 AM

Views: 37

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats