Skip to main content

CVE-2025-32454: CWE-125: Out-of-bounds Read in Siemens Teamcenter Visualization V14.3

High
VulnerabilityCVE-2025-32454cvecve-2025-32454cwe-125
Published: Tue May 13 2025 (05/13/2025, 09:38:44 UTC)
Source: CVE
Vendor/Project: Siemens
Product: Teamcenter Visualization V14.3

Description

A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.14), Teamcenter Visualization V2312 (All versions < V2312.0010), Teamcenter Visualization V2406 (All versions < V2406.0008), Teamcenter Visualization V2412 (All versions < V2412.0004), Tecnomatix Plant Simulation V2404 (All versions < V2404.0013). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.

AI-Powered Analysis

AILast updated: 07/12/2025, 05:16:12 UTC

Technical Analysis

CVE-2025-32454 is a high-severity vulnerability affecting multiple versions of Siemens Teamcenter Visualization and Tecnomatix Plant Simulation products. The flaw is classified as CWE-125, an out-of-bounds read vulnerability, which occurs when the affected applications parse specially crafted WRL (VRML) files. Specifically, the vulnerability arises from reading past the end of an allocated memory structure during file parsing, which can lead to memory corruption. This memory corruption can be exploited by an attacker to execute arbitrary code within the context of the current process. The affected products include Teamcenter Visualization versions prior to V14.3.0.14, V2312 prior to V2312.0010, V2406 prior to V2406.0008, V2412 prior to V2412.0004, and Tecnomatix Plant Simulation versions prior to V2404.0013. The CVSS v3.1 base score is 7.8, indicating a high severity level. The vector string (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H) shows that the attack requires local access (AV:L), low attack complexity (AC:L), no privileges (PR:N), but does require user interaction (UI:R). The scope is unchanged (S:U), and the impact on confidentiality, integrity, and availability is high (C:H/I:H/A:H). No known exploits are reported in the wild yet, and no patches are linked in the provided data, suggesting that mitigation may rely on vendor updates or workarounds once available. This vulnerability is critical for environments where untrusted WRL files might be opened or processed, as it can lead to full compromise of the affected application process.

Potential Impact

For European organizations, this vulnerability poses a significant risk, especially those in manufacturing, engineering, and industrial sectors that rely on Siemens Teamcenter Visualization and Tecnomatix Plant Simulation software for product lifecycle management and simulation. Exploitation could lead to unauthorized code execution, data theft, or disruption of critical design and simulation workflows. Given the high confidentiality, integrity, and availability impact, attackers could manipulate design data, cause downtime, or pivot within networks. The requirement for local access and user interaction limits remote exploitation but insider threats or social engineering attacks could trigger the vulnerability. The potential for code execution means malware deployment or lateral movement within corporate networks is possible, threatening intellectual property and operational continuity. Additionally, regulatory compliance risks arise if sensitive data is exposed or systems are compromised, impacting GDPR adherence and industrial cybersecurity standards.

Mitigation Recommendations

European organizations should implement the following specific mitigations: 1) Immediately restrict access to Siemens Teamcenter Visualization and Tecnomatix Plant Simulation applications to trusted users only, minimizing exposure to untrusted WRL files. 2) Educate users about the risks of opening unverified WRL files and enforce strict file handling policies. 3) Monitor and control local access to systems running the affected software, employing endpoint detection and response (EDR) tools to detect anomalous behavior indicative of exploitation attempts. 4) Apply vendor patches or updates as soon as Siemens releases them; in the absence of patches, consider disabling or restricting WRL file parsing features if feasible. 5) Use application whitelisting and sandboxing techniques to limit the impact of potential code execution within these applications. 6) Conduct regular vulnerability assessments and penetration testing focused on these software components to identify exposure. 7) Maintain robust backup and incident response plans to quickly recover from potential compromises.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
siemens
Date Reserved
2025-04-08T15:46:35.199Z
Cisa Enriched
true
Cvss Version
3.1
State
PUBLISHED

Threat ID: 682d9815c4522896dcbd64c0

Added to database: 5/21/2025, 9:08:37 AM

Last enriched: 7/12/2025, 5:16:12 AM

Last updated: 7/26/2025, 8:30:24 AM

Views: 15

Actions

PRO

Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.

Latest Threats