CVE-2025-3713: CWE-122 Heap-based Buffer Overflow in ATEN CL5708IM
The LCD KVM over IP Switch CL5708IM has a Heap-based Buffer Overflow vulnerability in firmware versions prior to v2.2.215, allowing unauthenticated remote attackers to exploit this vulnerability to perform a denial-of-service attack.
AI Analysis
Technical Summary
CVE-2025-3713 is a high-severity heap-based buffer overflow vulnerability identified in the firmware of the ATEN CL5708IM LCD KVM over IP Switch, specifically affecting versions prior to v2.2.215. This device is used to manage multiple computers remotely via a single keyboard, video monitor, and mouse setup over IP networks. The vulnerability arises from improper handling of memory buffers in the device's firmware, allowing an unauthenticated remote attacker to trigger a heap overflow. Exploitation does not require any authentication or user interaction, making it accessible to attackers with network access to the device. The primary impact of this vulnerability is a denial-of-service (DoS) condition, where the device can crash or become unresponsive, disrupting remote management capabilities. The CVSS 3.1 base score of 7.5 reflects the network attack vector, low attack complexity, no privileges required, no user interaction, and a high impact on availability, with no impact on confidentiality or integrity. No known exploits are currently reported in the wild, and no patches have been linked yet, indicating that mitigation may rely on vendor firmware updates once released. The vulnerability is categorized under CWE-122, which involves heap-based buffer overflows, a common and dangerous class of memory corruption bugs that can lead to crashes or potentially code execution in other contexts, though this report only confirms DoS impact. Given the device's role in critical infrastructure for remote server and workstation management, this vulnerability poses a significant risk to operational continuity in environments relying on ATEN KVM switches.
Potential Impact
For European organizations, the impact of CVE-2025-3713 could be substantial, especially in sectors that depend heavily on remote management of IT infrastructure, such as data centers, telecommunications, financial services, and government agencies. A successful exploitation leading to denial-of-service would disrupt administrative access to multiple servers or workstations, potentially halting critical operations and delaying incident response or maintenance activities. This could increase downtime, operational costs, and risk of cascading failures if administrators cannot quickly regain control. Although the vulnerability does not directly compromise data confidentiality or integrity, the loss of availability in management consoles can indirectly affect security posture by delaying patching, monitoring, and incident handling. European organizations with distributed IT environments or those using ATEN CL5708IM devices in high-availability setups are particularly at risk. Moreover, the unauthenticated nature of the exploit means that attackers do not need credentials, increasing the threat from external attackers who can reach the device over the network. This elevates the risk profile in environments where these devices are exposed to less-trusted networks or insufficiently segmented internal networks.
Mitigation Recommendations
Immediate mitigation should focus on network-level protections to restrict access to the ATEN CL5708IM devices. Organizations should implement strict firewall rules and network segmentation to ensure that only authorized management stations can reach the KVM switch IP addresses, ideally limiting access to trusted internal networks or VPNs. Monitoring network traffic for unusual access attempts to these devices can provide early warning of exploitation attempts. Since no patches are currently linked, organizations should engage with ATEN to obtain firmware updates or security advisories and apply updates as soon as they become available. Additionally, consider deploying intrusion detection/prevention systems (IDS/IPS) with signatures targeting anomalous traffic patterns associated with heap overflow attempts against these devices. For critical environments, temporary compensating controls such as disabling remote IP management features or physically isolating the device until patched may be warranted. Regularly auditing device firmware versions and configurations will help maintain awareness of exposure. Finally, documenting and rehearsing incident response plans for KVM device outages will reduce recovery time if exploitation occurs.
Affected Countries
Germany, France, United Kingdom, Netherlands, Italy, Spain, Sweden, Belgium
CVE-2025-3713: CWE-122 Heap-based Buffer Overflow in ATEN CL5708IM
Description
The LCD KVM over IP Switch CL5708IM has a Heap-based Buffer Overflow vulnerability in firmware versions prior to v2.2.215, allowing unauthenticated remote attackers to exploit this vulnerability to perform a denial-of-service attack.
AI-Powered Analysis
Technical Analysis
CVE-2025-3713 is a high-severity heap-based buffer overflow vulnerability identified in the firmware of the ATEN CL5708IM LCD KVM over IP Switch, specifically affecting versions prior to v2.2.215. This device is used to manage multiple computers remotely via a single keyboard, video monitor, and mouse setup over IP networks. The vulnerability arises from improper handling of memory buffers in the device's firmware, allowing an unauthenticated remote attacker to trigger a heap overflow. Exploitation does not require any authentication or user interaction, making it accessible to attackers with network access to the device. The primary impact of this vulnerability is a denial-of-service (DoS) condition, where the device can crash or become unresponsive, disrupting remote management capabilities. The CVSS 3.1 base score of 7.5 reflects the network attack vector, low attack complexity, no privileges required, no user interaction, and a high impact on availability, with no impact on confidentiality or integrity. No known exploits are currently reported in the wild, and no patches have been linked yet, indicating that mitigation may rely on vendor firmware updates once released. The vulnerability is categorized under CWE-122, which involves heap-based buffer overflows, a common and dangerous class of memory corruption bugs that can lead to crashes or potentially code execution in other contexts, though this report only confirms DoS impact. Given the device's role in critical infrastructure for remote server and workstation management, this vulnerability poses a significant risk to operational continuity in environments relying on ATEN KVM switches.
Potential Impact
For European organizations, the impact of CVE-2025-3713 could be substantial, especially in sectors that depend heavily on remote management of IT infrastructure, such as data centers, telecommunications, financial services, and government agencies. A successful exploitation leading to denial-of-service would disrupt administrative access to multiple servers or workstations, potentially halting critical operations and delaying incident response or maintenance activities. This could increase downtime, operational costs, and risk of cascading failures if administrators cannot quickly regain control. Although the vulnerability does not directly compromise data confidentiality or integrity, the loss of availability in management consoles can indirectly affect security posture by delaying patching, monitoring, and incident handling. European organizations with distributed IT environments or those using ATEN CL5708IM devices in high-availability setups are particularly at risk. Moreover, the unauthenticated nature of the exploit means that attackers do not need credentials, increasing the threat from external attackers who can reach the device over the network. This elevates the risk profile in environments where these devices are exposed to less-trusted networks or insufficiently segmented internal networks.
Mitigation Recommendations
Immediate mitigation should focus on network-level protections to restrict access to the ATEN CL5708IM devices. Organizations should implement strict firewall rules and network segmentation to ensure that only authorized management stations can reach the KVM switch IP addresses, ideally limiting access to trusted internal networks or VPNs. Monitoring network traffic for unusual access attempts to these devices can provide early warning of exploitation attempts. Since no patches are currently linked, organizations should engage with ATEN to obtain firmware updates or security advisories and apply updates as soon as they become available. Additionally, consider deploying intrusion detection/prevention systems (IDS/IPS) with signatures targeting anomalous traffic patterns associated with heap overflow attempts against these devices. For critical environments, temporary compensating controls such as disabling remote IP management features or physically isolating the device until patched may be warranted. Regularly auditing device firmware versions and configurations will help maintain awareness of exposure. Finally, documenting and rehearsing incident response plans for KVM device outages will reduce recovery time if exploitation occurs.
Affected Countries
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- twcert
- Date Reserved
- 2025-04-16T07:46:04.282Z
- Cisa Enriched
- true
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 682d9817c4522896dcbd778d
Added to database: 5/21/2025, 9:08:39 AM
Last enriched: 7/6/2025, 1:54:45 AM
Last updated: 8/18/2025, 11:35:16 PM
Views: 17
Related Threats
CVE-2025-9134: Improper Export of Android Application Components in AfterShip Package Tracker App
MediumCVE-2025-4690: CWE-1333 Inefficient Regular Expression Complexity in Google AngularJS
MediumCVE-2025-4046: CWE-862 Missing Authorization in Lexmark Lexmark Cloud Services
HighCVE-2025-4044: CWE-611 Improper Restriction of XML External Entity Reference in Lexmark Universal Print Driver
HighCVE-2025-9139: Information Disclosure in Scada-LTS
MediumActions
Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.